Javascript must be enabled to continue!
Feasibility Study on Electrical Properties of 20 kV Polymeric Insulator Dry Test and Rainwater Test
View through CrossRef
Insulator is a very important equipment in an electric power system. Ceramic insulators have been widely used to support conductors in 20 kV power lines. The problem of ceramic insulators is that they are heavy, easily contaminated on the surface and require a lot of energy in the manufacturing process. Therefore, polymer insulators were developed. This paper presents the design of an epoxy resin polymer insulator with Titanium Dioxide (TiO2) as a nanofiller. The leakage current test was carried out in a high voltage laboratory by applying an AC high voltage of 50 Hz to the insulator dry conditions and the insulator wetted by rainwater contaminants. The results of the leakage current test in dry conditions are 487.6 μA, rainwater contaminated conditions are 594.93 μA, insulation resistance in dry conditions is 2.07 G-Ohms, and contaminated conditions are 1.41 G-Ohms. Based on the test results show that the insulator leakage current increases up to 22% when the surface of the insulator is contaminated with rainwater. Meanwhile, the insulation resistance decreased by up to 32% in conditions contaminated with rainwater. The value of leakage current and insulation resistance indicates that the epoxy resin insulator with TiO2 as filler is electrically feasible to use.
Jurnal Rekayasa Elektrika (JRE)
Title: Feasibility Study on Electrical Properties of 20 kV Polymeric Insulator Dry Test and Rainwater Test
Description:
Insulator is a very important equipment in an electric power system.
Ceramic insulators have been widely used to support conductors in 20 kV power lines.
The problem of ceramic insulators is that they are heavy, easily contaminated on the surface and require a lot of energy in the manufacturing process.
Therefore, polymer insulators were developed.
This paper presents the design of an epoxy resin polymer insulator with Titanium Dioxide (TiO2) as a nanofiller.
The leakage current test was carried out in a high voltage laboratory by applying an AC high voltage of 50 Hz to the insulator dry conditions and the insulator wetted by rainwater contaminants.
The results of the leakage current test in dry conditions are 487.
6 μA, rainwater contaminated conditions are 594.
93 μA, insulation resistance in dry conditions is 2.
07 G-Ohms, and contaminated conditions are 1.
41 G-Ohms.
Based on the test results show that the insulator leakage current increases up to 22% when the surface of the insulator is contaminated with rainwater.
Meanwhile, the insulation resistance decreased by up to 32% in conditions contaminated with rainwater.
The value of leakage current and insulation resistance indicates that the epoxy resin insulator with TiO2 as filler is electrically feasible to use.
Related Results
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
A survey on the need to incorporate rainwater harvesting systems as an alternative domestic water source in Ghana
A survey on the need to incorporate rainwater harvesting systems as an alternative domestic water source in Ghana
This research survey seeks to gather responses in rainwater gathering and storage using harvesting systems as a key alternative. About 502 responses were gathered. Averaging 8 pers...
Studi Pengaruh Kualitas Air Hujan terhadap Kelangsungan Hidup (Survival Rate) Benih Ikan Komet (Carassius auratus)
Studi Pengaruh Kualitas Air Hujan terhadap Kelangsungan Hidup (Survival Rate) Benih Ikan Komet (Carassius auratus)
Rainwater is often considered to have a negative impact on the survival of fish fry, mainly due to its slightly acidic pH. However, this study aims to investigate the effect of rai...
ANALYZING THE WILLINGNESS TO WORK AND WILLINGNESS TO PAY FOR RWH IN JAPAN
ANALYZING THE WILLINGNESS TO WORK AND WILLINGNESS TO PAY FOR RWH IN JAPAN
Citizen participation of rainwater harvesting is a valuable practice to mitigate problems such as groundwater mining, land subsidence, and urban flooding cause by global warming an...
ASSESSING RAINWATER QUALITY ACROSS URBAN LAND USES IN ILORIN METROPOLIS
ASSESSING RAINWATER QUALITY ACROSS URBAN LAND USES IN ILORIN METROPOLIS
Rainwater can contain significant amounts of pollutants such as heavy metals, nutrients, and pathogens as a result of various anthropogenic activities resulting from land use types...
Monitoring Rainwater Properties and Outdoor Particulate Matter in a Former Steel Manufacturing City in Romania
Monitoring Rainwater Properties and Outdoor Particulate Matter in a Former Steel Manufacturing City in Romania
Wet deposition is influencing air quality because air pollutants are washed away from the surrounding air. Consequently, particulate matter and associated compounds are transported...
Rainwater Quality Disparities Across Malaysian Peninsula Sites
Rainwater Quality Disparities Across Malaysian Peninsula Sites
This research describes the physicochemical quality of harvested rainwater at four distinct locations in Peninsula Malaysia. The evaluation of rainwater quality across different ge...
Research on Risk Assessment and Control for Urban Rainwater Resources Utilization
Research on Risk Assessment and Control for Urban Rainwater Resources Utilization
Strengthening risk management and control of urban rainwater resources utilization is the key to ensuring the sustainable and efficient use of urban rainwater resources. On the bas...

