Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Effect of Penetration Rate on Insertion Force in Trabecular Bone Biopsy

View through CrossRef
Bone biopsy is a common procedure in bone disease diagnoses, therapies and research. In this procedure, bone biopsy needles are inserted into bone tissues. Although needle insertion into bone is often essential for the diagnosis of bone diseases, the hard tissue-needle interactions are not quantitatively understood. In this paper, we describe a quantitative assessment of forces involved in insertion of healthy trabecular bone using clinically applied Jamshidi CrownTM bone biopsy needles of gauge 8 (4-mm diameter). The measured forces were related to the insertion depths up to 25 mm and insertion rates of 1 mm/s to 5 mm/s. At the initial insertion stage, a clear linear force-depth relation was measured. With the increase of the insertion depth, the forces increased nonlinearly. In the final stage of insertion, the forces increased much more quickly at the lower insertion rate than that at the higher insertion rate. The maximum insertion force reached approximately 1000 N when the insertion depth reached 25 mm at the insertion rate of 1 mm/s.
Title: Effect of Penetration Rate on Insertion Force in Trabecular Bone Biopsy
Description:
Bone biopsy is a common procedure in bone disease diagnoses, therapies and research.
In this procedure, bone biopsy needles are inserted into bone tissues.
Although needle insertion into bone is often essential for the diagnosis of bone diseases, the hard tissue-needle interactions are not quantitatively understood.
In this paper, we describe a quantitative assessment of forces involved in insertion of healthy trabecular bone using clinically applied Jamshidi CrownTM bone biopsy needles of gauge 8 (4-mm diameter).
The measured forces were related to the insertion depths up to 25 mm and insertion rates of 1 mm/s to 5 mm/s.
At the initial insertion stage, a clear linear force-depth relation was measured.
With the increase of the insertion depth, the forces increased nonlinearly.
In the final stage of insertion, the forces increased much more quickly at the lower insertion rate than that at the higher insertion rate.
The maximum insertion force reached approximately 1000 N when the insertion depth reached 25 mm at the insertion rate of 1 mm/s.

Related Results

Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Poster 107: The Use of Coacervate Sustained Release System to Identify the Most Potent BMP for Bone Regeneration
Objectives: Bone morphogenetic proteins (BMPs) belong to the transforming growth factor superfamily that were first discovered by Marshall Urist. There are 14 B...
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
Macroeconomic and Social Precursors of Suicide Rates in the Philippines: A Quantitative Analysis (Preprint)
BACKGROUND Suicide is a complex, serious and multifaceted public health issue that poses significant challenges to societies worldwide. In fact, it represen...
Abnormalities in Bone Mineral Density and Bone Histology in Thalassemia
Abnormalities in Bone Mineral Density and Bone Histology in Thalassemia
Abstract This study demonstrated that there was extensive iron staining on trabecular surface and marked reduction in trabecular bone volume without significant alte...
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract Introduction Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...

Back to Top