Javascript must be enabled to continue!
Water Sorption and Solubility Behavior of Provisional Restorative Materials Fabricated by Conventional, CAD/CAM, and 3D printing Methods
View through CrossRef
Aims: The present study aimed to assess and compare the levels of water sorption and solubility of provisional restorative materials manufactured by conventional, CAD/CAM, or 3D printing methods. Materials and Methods: A total of forty-two circular samples of (15mm × 2 mm diameter, thickness respectively) respectively were fabricated and divided into three groups (n= 7 for each sample): Group A: 3D-printed at 0°, 15°, and 45° build angles by using a digital light processing (DLP) printer (Creality LD-006, China) with (FREEPRINT® temp resin, Jermany), Group B: CAD/CAM milled at high (5-8m) and low (8-15m) speed by using pre-polymerized PMMA blocks (Dental Direct polyX ML, Jermany) using a 5-axis milling machine (Zahndent, China), Group C: Conventional self-curing interim resin IMICRYL® (Imident powder. Turky). All samples were tested for water sorption and solubility tests. The collected data were statistically analyzed using one-way ANOVA and independent t-tests, with the significance level set at 0.05. Results: The results of the one-way ANOVA test indicated a statistically significant variation (P ≤ 0.01) in water sorption values between 3D-printed provisional restorations fabricated with build angles of 0°, 15°, and 45°, but not in water solubility, for which there was no significant difference (P > 0.05). However, Independent samples t-tests showed no statistically significant difference (P > 0.05), indicating that the variation in milling speeds, low (8-15 m/min) versus high (5-8 m/min) had no detectable effect on water sorption or solubility in the CAD/CAM groups. Comparing all the fabrication processes, ANOVA indicated significant differences (P ≤ 0.05) in both parameters. Duncan’s test showed the highest water sorption in 3D-printed 0° (1.0029 μg/mm³), followed by 15° (0.878 μg/mm³) and 45° (0.8177 μg/mm³). CAD/CAM low-speed milling had 1.1501 μg/mm³ and high-speed 1.1069 μg/mm³, while conventional PMMA had 1.0078 μg/mm³. For water solubility, conventional PMMA had the highest mean value (0.0887 μg/mm³), and the 3D-printed 0° group had the lowest (0.0183 μg/mm³). Conclusion: Results indicate that fabrication method and build orientation influence the water sorption and water solubility of provisional restorative materials. 3D-printed restorations, particularly those printed at a 0° build angle, exhibited the least solubility and good water resistance compared to CAD/CAM and control PMMA groups. The results demonstrate the potential of optimized 3D printing parameters in producing long-lasting, water-resistant provisional restorations.
Title: Water Sorption and Solubility Behavior of Provisional Restorative Materials Fabricated by Conventional, CAD/CAM, and 3D printing Methods
Description:
Aims: The present study aimed to assess and compare the levels of water sorption and solubility of provisional restorative materials manufactured by conventional, CAD/CAM, or 3D printing methods.
Materials and Methods: A total of forty-two circular samples of (15mm × 2 mm diameter, thickness respectively) respectively were fabricated and divided into three groups (n= 7 for each sample): Group A: 3D-printed at 0°, 15°, and 45° build angles by using a digital light processing (DLP) printer (Creality LD-006, China) with (FREEPRINT® temp resin, Jermany), Group B: CAD/CAM milled at high (5-8m) and low (8-15m) speed by using pre-polymerized PMMA blocks (Dental Direct polyX ML, Jermany) using a 5-axis milling machine (Zahndent, China), Group C: Conventional self-curing interim resin IMICRYL® (Imident powder.
Turky).
All samples were tested for water sorption and solubility tests.
The collected data were statistically analyzed using one-way ANOVA and independent t-tests, with the significance level set at 0.
05.
Results: The results of the one-way ANOVA test indicated a statistically significant variation (P ≤ 0.
01) in water sorption values between 3D-printed provisional restorations fabricated with build angles of 0°, 15°, and 45°, but not in water solubility, for which there was no significant difference (P > 0.
05).
However, Independent samples t-tests showed no statistically significant difference (P > 0.
05), indicating that the variation in milling speeds, low (8-15 m/min) versus high (5-8 m/min) had no detectable effect on water sorption or solubility in the CAD/CAM groups.
Comparing all the fabrication processes, ANOVA indicated significant differences (P ≤ 0.
05) in both parameters.
Duncan’s test showed the highest water sorption in 3D-printed 0° (1.
0029 μg/mm³), followed by 15° (0.
878 μg/mm³) and 45° (0.
8177 μg/mm³).
CAD/CAM low-speed milling had 1.
1501 μg/mm³ and high-speed 1.
1069 μg/mm³, while conventional PMMA had 1.
0078 μg/mm³.
For water solubility, conventional PMMA had the highest mean value (0.
0887 μg/mm³), and the 3D-printed 0° group had the lowest (0.
0183 μg/mm³).
Conclusion: Results indicate that fabrication method and build orientation influence the water sorption and water solubility of provisional restorative materials.
3D-printed restorations, particularly those printed at a 0° build angle, exhibited the least solubility and good water resistance compared to CAD/CAM and control PMMA groups.
The results demonstrate the potential of optimized 3D printing parameters in producing long-lasting, water-resistant provisional restorations.
Related Results
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
Aplicabilidade dos sistemas CAD/CAM em Prótese Total: revisão de literatura
Aplicabilidade dos sistemas CAD/CAM em Prótese Total: revisão de literatura
Introdução: A tecnologia CAD/CAM possui múltiplas aplicações protéticas, incluindo a prótese total. Objetivos: realizar uma revisão de literatura sobre a aplicabilidade dos sistema...
Water Sorption and Water Solubility of Digitally Fabricated Denture Base Materials
Water Sorption and Water Solubility of Digitally Fabricated Denture Base Materials
(1) Background: Digitally fabricated denture base materials are increasingly used in everyday clinical practice, but scientific data on their properties is limited, especially rega...
Evaluation of Provisional Restorations
Evaluation of Provisional Restorations
Objective: This study aimed to evaluate and compare the flexural strength, microhardness, surface roughness, and color stability of provisional materials made using 3D printing, CA...
CAD/CAM Library of Parts and Assemblies for Engineering Curricula
CAD/CAM Library of Parts and Assemblies for Engineering Curricula
Most often instructors and students are forced to search through a wide range of scattered resources, such as textbooks, archival journals, conference proceedings, Websites, and in...
Genetic relations between leukocyte counts, type 1 diabetes, and coronary artery disease
Genetic relations between leukocyte counts, type 1 diabetes, and coronary artery disease
Abstract
Hypothesis/Aim
Type 1 diabetes (T1D) is associated with excess coronary artery disease (CAD) risk even when known card...
Color Appearance of Various Provisional Restorative Materials for Rehabilitation Upon Aging
Color Appearance of Various Provisional Restorative Materials for Rehabilitation Upon Aging
Abstract
Objectives Color stability of provisional restoration is crucial for full mouth reconstruction, which is probably influenced by aging. Therefore, this study eval...
Evolution and significance of CaM KMT- Calmodulin interaction- A journey of more than 40 years
Evolution and significance of CaM KMT- Calmodulin interaction- A journey of more than 40 years
The calmodulin (CaM) family serves as the primary calcium sensor. Upon receiving calcium signals, CaM binds calcium ions and regulates the activity of numerous effector proteins. I...

