Arterial Input Function (AIF) Correction Using AIF Plus Tissue Inputs with a Bi-LSTM Network
View through CrossRef
Background: The arterial input function (AIF) is vital for myocardial blood flow quantification in cardiac MRI to indicate the input time–concentration curve of a contrast agent. Inaccurate AIFs can significantly affect perfusion quantification. Purpose: When only saturated and biased AIFs are measured, this work investigates multiple ways of leveraging tissue curve information, including using AIF + tissue curves as inputs and optimizing the loss function for deep neural network training. Methods: Simulated data were generated using a 12-parameter AIF mathematical model for the AIF. Tissue curves were created from true AIFs combined with compartment-model parameters from a random distribution. Using Bloch simulations, a dictionary was constructed for a saturation-recovery 3D radial stack-of-stars sequence, accounting for deviations such as flip angle, T2* effects, and residual longitudinal magnetization after the saturation. A preliminary simulation study established the optimal tissue curve number using a bidirectional long short-term memory (Bi-LSTM) network with just AIF loss. Further optimization of the loss function involves comparing just AIF loss, AIF with compartment-model-based parameter loss, and AIF with compartment-model tissue loss. The optimized network was examined with both simulation and hybrid data, which included in vivo 3D stack-of-star datasets for testing. The AIF peak value accuracy and ktrans results were assessed. Results: Increasing the number of tissue curves can be beneficial when added tissue curves can provide extra information. Using just the AIF loss outperforms the other two proposed losses, including adding either a compartment-model-based tissue loss or a compartment-model parameter loss to the AIF loss. With the simulated data, the Bi-LSTM network reduced the AIF peak error from −23.6 ± 24.4% of the AIF using the dictionary method to 0.2 ± 7.2% (AIF input only) and 0.3 ± 2.5% (AIF + ten tissue curve inputs) of the network AIF. The corresponding ktrans error was reduced from −13.5 ± 8.8% to −0.6 ± 6.6% and 0.3 ± 2.1%. With the hybrid data (simulated data for training; in vivo data for testing), the AIF peak error was 15.0 ± 5.3% and the corresponding ktrans error was 20.7 ± 11.6% for the AIF using the dictionary method. The hybrid data revealed that using the AIF + tissue inputs reduced errors, with peak error (1.3 ± 11.1%) and ktrans error (−2.4 ± 6.7%). Conclusions: Integrating tissue curves with AIF curves into network inputs improves the precision of AI-driven AIF corrections. This result was seen both with simulated data and with applying the network trained only on simulated data to a limited in vivo test dataset.
Title: Arterial Input Function (AIF) Correction Using AIF Plus Tissue Inputs with a Bi-LSTM Network
Description:
Background: The arterial input function (AIF) is vital for myocardial blood flow quantification in cardiac MRI to indicate the input time–concentration curve of a contrast agent.
Inaccurate AIFs can significantly affect perfusion quantification.
Purpose: When only saturated and biased AIFs are measured, this work investigates multiple ways of leveraging tissue curve information, including using AIF + tissue curves as inputs and optimizing the loss function for deep neural network training.
Methods: Simulated data were generated using a 12-parameter AIF mathematical model for the AIF.
Tissue curves were created from true AIFs combined with compartment-model parameters from a random distribution.
Using Bloch simulations, a dictionary was constructed for a saturation-recovery 3D radial stack-of-stars sequence, accounting for deviations such as flip angle, T2* effects, and residual longitudinal magnetization after the saturation.
A preliminary simulation study established the optimal tissue curve number using a bidirectional long short-term memory (Bi-LSTM) network with just AIF loss.
Further optimization of the loss function involves comparing just AIF loss, AIF with compartment-model-based parameter loss, and AIF with compartment-model tissue loss.
The optimized network was examined with both simulation and hybrid data, which included in vivo 3D stack-of-star datasets for testing.
The AIF peak value accuracy and ktrans results were assessed.
Results: Increasing the number of tissue curves can be beneficial when added tissue curves can provide extra information.
Using just the AIF loss outperforms the other two proposed losses, including adding either a compartment-model-based tissue loss or a compartment-model parameter loss to the AIF loss.
With the simulated data, the Bi-LSTM network reduced the AIF peak error from −23.
6 ± 24.
4% of the AIF using the dictionary method to 0.
2 ± 7.
2% (AIF input only) and 0.
3 ± 2.
5% (AIF + ten tissue curve inputs) of the network AIF.
The corresponding ktrans error was reduced from −13.
5 ± 8.
8% to −0.
6 ± 6.
6% and 0.
3 ± 2.
1%.
With the hybrid data (simulated data for training; in vivo data for testing), the AIF peak error was 15.
0 ± 5.
3% and the corresponding ktrans error was 20.
7 ± 11.
6% for the AIF using the dictionary method.
The hybrid data revealed that using the AIF + tissue inputs reduced errors, with peak error (1.
3 ± 11.
1%) and ktrans error (−2.
4 ± 6.
7%).
Conclusions: Integrating tissue curves with AIF curves into network inputs improves the precision of AI-driven AIF corrections.
This result was seen both with simulated data and with applying the network trained only on simulated data to a limited in vivo test dataset.
Related Results
Abstract PO006: The Role of Obesity-associated Allograft Inflammatory Factor-1 in Liver Cancer Cell Growth
Abstract PO006: The Role of Obesity-associated Allograft Inflammatory Factor-1 in Liver Cancer Cell Growth
Abstract
Introduction: Obesity is a risk factor in the development of liver cancer. The obesogenic tumor microenvironment is of particular importance in liver tumori...
Caspases Required for AIF Release
Caspases Required for AIF Release
Apoptosis-inducing factor (AIF) is a mitochondrial protein that is released during programmed cell death and contributes to DNA fragmentation. AIF-induced cell death has been descr...
Mass Conserving LSTM with Dual States for Improved Streamflow Prediction through Quickflow and Slow Storage Separation
Mass Conserving LSTM with Dual States for Improved Streamflow Prediction through Quickflow and Slow Storage Separation
Long-Short Term Memory (LSTM) shows exceptional performance for rainfall-runoff modelling, but lacks physical realism. Efforts to integrate mass conserving into the model architect...
Streamflow simulations using regionalized Long Short-Term Memory (LSTM) neural network models in contrasting climatic conditions
Streamflow simulations using regionalized Long Short-Term Memory (LSTM) neural network models in contrasting climatic conditions
We investigate the potential of using Long Short-Term Memory (LSTM) neural networks for estimating streamflow in (sub)tropical catchments under contrasting hydroclimatic regimes (s...
Self‐Assembly of Anti‐Inflammatory Peptide Amphiphiles for Mucosal Health
Self‐Assembly of Anti‐Inflammatory Peptide Amphiphiles for Mucosal Health
Broad spectrum anti‐inflammatory peptide amphiphiles (AIF‐PAs) have been developed as an innovative strategy for the treatment of chronic mucosal inflammation and the prevention of...
The Effect of Intravenous Glutamine Administration in Lowering AIF Expression in Renal Tubular Cells
The Effect of Intravenous Glutamine Administration in Lowering AIF Expression in Renal Tubular Cells
Highlights
Glutamine, an amino acid, can help mitigate the side effects of cisplatin by boosting glutathione (GSH) levels, an antioxidant that counteracts oxidative stress.
By red...
Runoff Simulation in Data-Scarce Alpine Regions: Comparative Analysis Based on LSTM and Physically Based Models
Runoff Simulation in Data-Scarce Alpine Regions: Comparative Analysis Based on LSTM and Physically Based Models
Runoff simulation is essential for effective water resource management and plays a pivotal role in hydrological forecasting. Improving the quality of runoff simulation and forecast...