Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Chronometric vs. Structural Hypercoagulability

View through CrossRef
Prolonged tourniquet stasis induced by venepuncture can lead to the release of the plasma of cell lysis products, as well as tissue factor (TF), impairing the quality of coagulation test results. The accidental presence of TF in vitro can trigger the coagulation mechanism, generating a false decrease in prothrombin time (PT). Background and Objectives: Identification of short PT tests below the normal reference value that could suggest a situation of hypercoagulability. The study aimed to compare the results of the shortened PT tests at their first determination with the eventual correction following duplication of the analysis from the same sample. Materials and methods: Identification of the shortened PT tests has been carried out for a period of 4 months, upon 544 coagulation samples referred to the Hematology department of Sf. Spiridon County Clinical Emergency Hospital from Iasi, Romania. Results: Out of the 544 samples of which the results indicated a state of hypercoagulability, by repeating the determination from the same sample, for 200 (36.76%) PT tests (p = 0.001) the value was corrected, falling within the normal reference range. For 344 (63.24%) tests, the results suggested a situation of hypercoagulability. Conclusions: In order to guarantee the highest quality of the laboratory services, a proper interpretation and report of the patients’ results must be congruent and harmoniously associated to the actual clinical condition of the patient. Duplication of the PT determination from the same sample would exclude situations of false hypercoagulability and would provide significant improvement for the patient’s safety.
Title: Chronometric vs. Structural Hypercoagulability
Description:
Prolonged tourniquet stasis induced by venepuncture can lead to the release of the plasma of cell lysis products, as well as tissue factor (TF), impairing the quality of coagulation test results.
The accidental presence of TF in vitro can trigger the coagulation mechanism, generating a false decrease in prothrombin time (PT).
Background and Objectives: Identification of short PT tests below the normal reference value that could suggest a situation of hypercoagulability.
The study aimed to compare the results of the shortened PT tests at their first determination with the eventual correction following duplication of the analysis from the same sample.
Materials and methods: Identification of the shortened PT tests has been carried out for a period of 4 months, upon 544 coagulation samples referred to the Hematology department of Sf.
Spiridon County Clinical Emergency Hospital from Iasi, Romania.
Results: Out of the 544 samples of which the results indicated a state of hypercoagulability, by repeating the determination from the same sample, for 200 (36.
76%) PT tests (p = 0.
001) the value was corrected, falling within the normal reference range.
For 344 (63.
24%) tests, the results suggested a situation of hypercoagulability.
Conclusions: In order to guarantee the highest quality of the laboratory services, a proper interpretation and report of the patients’ results must be congruent and harmoniously associated to the actual clinical condition of the patient.
Duplication of the PT determination from the same sample would exclude situations of false hypercoagulability and would provide significant improvement for the patient’s safety.

Related Results

Form Follows Force: A theoretical framework for Structural Morphology, and Form-Finding research on shell structures
Form Follows Force: A theoretical framework for Structural Morphology, and Form-Finding research on shell structures
The springing up of freeform architecture and structures introduces many challenges to structural engineers. The main challenge is to generate structural forms with high structural...
Thromboelastographic Methods to Detect Hypercoagulability.
Thromboelastographic Methods to Detect Hypercoagulability.
Abstract 4006 Poster Board III-942 Introduction Venous thromboembolic events (VTE) cause significant morbidity an...
Hypercoagulability in critically ill patients with COVID 19, an observational prospective study
Hypercoagulability in critically ill patients with COVID 19, an observational prospective study
Objective COVID 19 is often associated with hypercoagulability and thromboembolic (TE) events. The aim of this study was to assess the characteristics of hypercoagulability and its...
Hypercoagulability panel testing predicts thrombosis in neonates undergoing cardiac surgery
Hypercoagulability panel testing predicts thrombosis in neonates undergoing cardiac surgery
Thrombosis contributes to morbidity and mortality in neonates following cardiac surgery. Alterations in hemostatic factors following cardiac surgery have been described, but there ...
Close to the Edge: A Chronometric Approach to Early-Late Iron Age Transition (450-350 BCE) in the Iberian Peninsula
Close to the Edge: A Chronometric Approach to Early-Late Iron Age Transition (450-350 BCE) in the Iberian Peninsula
The transition around 400 BCE represents one of the most significant yet least understood transformations of the Iron Age. During this period, most European communities experienced...
Anticoagulants and Hypercoagulability
Anticoagulants and Hypercoagulability
Anticoagulants are chemical substances that prevent coagulation or prolong the clotting time by suppressing the functions or synthesis of coagulation factors in the blood. Anticoag...

Back to Top