A Cadaveric Study: Does Ankle Positioning Affect the Quality of Anatomic Syndesmosis Reduction?

View through CrossRef
OBJECTIVE: The objective of this study was to compare the quality of syndesmotic reduction with the ankle in maximal dorsiflexion versus neutral plantarflexion (normal resting position). METHODS: Baseline computed tomography (CT) imaging of 10 cadaveric ankle specimens from 5 donors was obtained with the ankles placed in normal resting position. Two fellowship-trained orthopaedic surgeons disrupted the syndesmosis of each ankle specimen. All ankles were then placed in neutral plantarflexion and were subsequently reduced with thumb pressure under direct visualization through an anterolateral approach and stabilized with one 0.062-inch K-wire placed from lateral to medial in a quadricortical fashion across the syndesmosis. Postreduction CT scans were then obtained with the ankle in normal resting position. This process was repeated with the ankles placed in maximal dorsiflexion during reduction and stabilization. Postreduction CT scans were then obtained with the ankles placed in normal resting position. All postreduction CT scans were compared with baseline CT imaging using mixed-effects linear regression with significance set at P < 0.05. RESULTS: Syndesmotic reduction and stabilization in maximal dorsiflexion led to increased external rotation of the fibula compared with baseline scans [13.0 ± 5.4 degrees (mean ± SD) vs. 7.5 ± 2.4 degrees, P = 0.002]. There was a tendency toward lateral translation of the fibula with the ankle reduced in maximal dorsiflexion (3.3 ± 1.0 vs. 2.7 ± 0.7 mm, P = 0.096). No other statistically significant differences between measurements of reduction with the ankle placed in neutral plantarflexion or maximal dorsiflexion compared with baseline were present (P > 0.05). CONCLUSIONS: Reducing the syndesmosis with the ankle in maximal dorsiflexion may lead to malreduction with external rotation of the fibula. There was no statistically significant difference in reduction quality with the ankle placed in neutral plantarflexion compared with baseline. Future studies should assess the clinical implications of ankle positioning during syndesmotic fixation.
Title: A Cadaveric Study: Does Ankle Positioning Affect the Quality of Anatomic Syndesmosis Reduction?
Description:
OBJECTIVE: The objective of this study was to compare the quality of syndesmotic reduction with the ankle in maximal dorsiflexion versus neutral plantarflexion (normal resting position).
METHODS: Baseline computed tomography (CT) imaging of 10 cadaveric ankle specimens from 5 donors was obtained with the ankles placed in normal resting position.
Two fellowship-trained orthopaedic surgeons disrupted the syndesmosis of each ankle specimen.
All ankles were then placed in neutral plantarflexion and were subsequently reduced with thumb pressure under direct visualization through an anterolateral approach and stabilized with one 0.
062-inch K-wire placed from lateral to medial in a quadricortical fashion across the syndesmosis.
Postreduction CT scans were then obtained with the ankle in normal resting position.
This process was repeated with the ankles placed in maximal dorsiflexion during reduction and stabilization.
Postreduction CT scans were then obtained with the ankles placed in normal resting position.
All postreduction CT scans were compared with baseline CT imaging using mixed-effects linear regression with significance set at P < 0.
05.
RESULTS: Syndesmotic reduction and stabilization in maximal dorsiflexion led to increased external rotation of the fibula compared with baseline scans [13.
0 ± 5.
4 degrees (mean ± SD) vs.
7.
5 ± 2.
4 degrees, P = 0.
002].
There was a tendency toward lateral translation of the fibula with the ankle reduced in maximal dorsiflexion (3.
3 ± 1.
0 vs.
2.
7 ± 0.
7 mm, P = 0.
096).
No other statistically significant differences between measurements of reduction with the ankle placed in neutral plantarflexion or maximal dorsiflexion compared with baseline were present (P > 0.
05).
CONCLUSIONS: Reducing the syndesmosis with the ankle in maximal dorsiflexion may lead to malreduction with external rotation of the fibula.
There was no statistically significant difference in reduction quality with the ankle placed in neutral plantarflexion compared with baseline.
Future studies should assess the clinical implications of ankle positioning during syndesmotic fixation.

Related Results

Syndesmosis Instability
Syndesmosis Instability
The syndesmosis is one of important stabilizer of the ankle joint and consists of a complex ligamentous structure: the anterior inferior tibiofibular ligament; the interosseous lig...
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
Revision Ankle Syndesmosis Fixation: Functional Outcome after TightRope® Fixation
ABSTRACT Introduction Syndesmotic injuries present a challenge to orthopedic surgeons. Malreduction of the syndesmosis has been reported to cause instability and secondary osteoar...
he prevalence and clinical presentation of fibularis myofascial trigger points in the assessment and treatment of inversion ankle sprains
he prevalence and clinical presentation of fibularis myofascial trigger points in the assessment and treatment of inversion ankle sprains
Ankle sprains account for 85% of all injuries to the ankle (Garrick, 1997). Inversion sprains result from a twisting of a weight-bearing foot into a plantarflexed and inverted posi...
Role of Syndesmotic Ligaments in Lateral Ankle Instability
Role of Syndesmotic Ligaments in Lateral Ankle Instability
Category: Ankle; Sports; Trauma Introduction/Purpose: Despite the success of surgi...
FRACTURES OF THE BONES IN THE ANKLE JOINT
FRACTURES OF THE BONES IN THE ANKLE JOINT
Introduction: Ankle fractures are usually frequent in emergency departments worldwide, with an incidence of 187/100,000 inhabitants per year. Especially the type B fracture accordi...
Percent Weightbearing in Foot and Ankle X-rays
Percent Weightbearing in Foot and Ankle X-rays
Category: Other; Ankle; Hindfoot; Midfoot/Forefoot Introduction/Purpose: Weightbearing x-rays remain standard of care in diagnosing and evaluating foot and ankle injuries and are c...
Intraoperative three-dimensional imaging in ankle syndesmotic reduction.
Intraoperative three-dimensional imaging in ankle syndesmotic reduction.
Abstract Background: Injuries of the distal syndesmosis in ankle fractures are traditionally treated with a temporary adjusting screw fixation. Conventional fluoroscopic an...
Intraoperative three-dimensional imaging in ankle syndesmotic reduction.
Intraoperative three-dimensional imaging in ankle syndesmotic reduction.
Abstract Background: Injuries of the distal syndesmosis in ankle fractures are traditionally treated with a temporary adjusting screw fixation. Conventional fluoroscopic an...

Back to Top