A precision raindrop generator to calibrate non-catching rain gauges
View through CrossRef
<p>The need for high-resolution and low maintenance weather stations is the major factor behind the increasing adoption of Non-Catching Gauges (NCGs) by national weather services and research institutions. Data from such instruments are used for several applications and in numerous research fields, where instrumental biases can have a strong impact. For NCGs, rigorous testing and calibration are more challenging than for catching gauges. Hydrometeor characteristics like particle size, shape, fall velocity and density must be carefully reproduced to provide the reference precipitation, instead of the equivalent water flow used for the calibration of catching gauges. Instrument calibration is usually declared by the manufacturers, using internal procedures developed for the specific technology employed. No standard calibration methodology exists, that encompass all or at least most of the available NCGs (Lanza et al. 2021). The EURAMET project 18NRM03 &#8216;INCIPIT&#8217; on the &#8216;Calibration and accuracy of non-catching instruments to measure liquid/solid atmospheric precipitation&#8217;, was initiated in 2019 to address such issues.</p><p>A calibration device was developed to achieve individual drop generation on demand and in-flight measurement of the released drops. Water drops in the range from 0.5 to 6 mm in diameter are generated to mimic natural raindrops. A high-precision syringe pump is used to form the drop of the desired volume at the tip of a calibrated nozzle. A high-voltage power supply is used to apply a large potential difference between the nozzle and a metallic ring, and the resulting electric field triggers the release of the drop. A precision motorized gantry moves the generator across the horizontal plane, to cover different releasing positions within the instrument sensing area. By either varying the release height or accelerating the drop using compressed air, different fractions of the terminal velocity can be achieved, depending on the drop size. A second gantry, just above the gauge under test, aligns the plane of focus of a high-resolution camera with the fall trajectory of the drop. Three images of the same drop are captured in a single picture, using speedlights triggered at fixed time intervals. Photogrammetric techniques and a photodiode to measure the time between flashes provide the shape, size, speed, and acceleration of the drop. This characterizes each released drop before it reaches the instrument sensing area and, by comparison with the gauge measurement, the instrumental bias is obtained. Laboratory tests are presented to assess the performance of the calibration device.</p><p>This work is funded as part of the activities of the EURAMET project 18NRM03 &#8220;INCIPIT Calibration and Accuracy of Non-Catching Instruments to measure liquid/solid atmospheric precipitation&#8221;. The project INCIPIT has received funding from the EMPIR programme co-financed by the Participating States and from the European Union&#8217;s Horizon 2020 research and innovation programme.</p><p><strong>References:</strong></p><p>Lanza L.G. and co-authors, 2021: Calibration of non-catching precipitation measurement instruments: a review. <em>J. Meteorological Applications,</em> 28.3(2021):e2002.</p>
Title: A precision raindrop generator to calibrate non-catching rain gauges
Description:
<p>The need for high-resolution and low maintenance weather stations is the major factor behind the increasing adoption of Non-Catching Gauges (NCGs) by national weather services and research institutions.
Data from such instruments are used for several applications and in numerous research fields, where instrumental biases can have a strong impact.
For NCGs, rigorous testing and calibration are more challenging than for catching gauges.
Hydrometeor characteristics like particle size, shape, fall velocity and density must be carefully reproduced to provide the reference precipitation, instead of the equivalent water flow used for the calibration of catching gauges.
Instrument calibration is usually declared by the manufacturers, using internal procedures developed for the specific technology employed.
No standard calibration methodology exists, that encompass all or at least most of the available NCGs (Lanza et al.
2021).
The EURAMET project 18NRM03 &#8216;INCIPIT&#8217; on the &#8216;Calibration and accuracy of non-catching instruments to measure liquid/solid atmospheric precipitation&#8217;, was initiated in 2019 to address such issues.
</p><p>A calibration device was developed to achieve individual drop generation on demand and in-flight measurement of the released drops.
Water drops in the range from 0.
5 to 6 mm in diameter are generated to mimic natural raindrops.
A high-precision syringe pump is used to form the drop of the desired volume at the tip of a calibrated nozzle.
A high-voltage power supply is used to apply a large potential difference between the nozzle and a metallic ring, and the resulting electric field triggers the release of the drop.
A precision motorized gantry moves the generator across the horizontal plane, to cover different releasing positions within the instrument sensing area.
By either varying the release height or accelerating the drop using compressed air, different fractions of the terminal velocity can be achieved, depending on the drop size.
A second gantry, just above the gauge under test, aligns the plane of focus of a high-resolution camera with the fall trajectory of the drop.
Three images of the same drop are captured in a single picture, using speedlights triggered at fixed time intervals.
Photogrammetric techniques and a photodiode to measure the time between flashes provide the shape, size, speed, and acceleration of the drop.
This characterizes each released drop before it reaches the instrument sensing area and, by comparison with the gauge measurement, the instrumental bias is obtained.
Laboratory tests are presented to assess the performance of the calibration device.
</p><p>This work is funded as part of the activities of the EURAMET project 18NRM03 &#8220;INCIPIT Calibration and Accuracy of Non-Catching Instruments to measure liquid/solid atmospheric precipitation&#8221;.
The project INCIPIT has received funding from the EMPIR programme co-financed by the Participating States and from the European Union&#8217;s Horizon 2020 research and innovation programme.
</p><p><strong>References:</strong></p><p>Lanza L.
G.
and co-authors, 2021: Calibration of non-catching precipitation measurement instruments: a review.
<em>J.
Meteorological Applications,</em> 28.
3(2021):e2002.
</p>.
Related Results
Evaluation of Selected Amateur Rain Gauges with Hellmann Rain Gauge Measurements
Evaluation of Selected Amateur Rain Gauges with Hellmann Rain Gauge Measurements
The paper compares precipitation measurements from the Stratus manual rain gauge from the CoCoRaHS network and two Davis Vantage Vue and Davis Vantage Pro 2A rain gauges with the H...
ecision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predi
ecision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predictive Analytics in Precision Farming and Predi
The scope of sensor networks and the Internet of Things spanning rapidly to diversified domains but not limited to sports, health, and business trading. In recent past, the sensors...
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Analisis Penyebab Pecahnya Cylinder Liner pada Generator Engine di Kapal MV. Kali Mas
Globalization has spurred the growth of the transportation sector. In this context, maintenance of generators on ship machinery is essential to ensure smooth ship operations. The g...
Raindrop Collision Outcomes in Persistent Precipitation over central China during Mei-yu Front
Raindrop Collision Outcomes in Persistent Precipitation over central China during Mei-yu Front
      The statistical characteristics of the raindrop size distribution (RSD) and raindrop collision outcomes over central China are in...
Improving Simulations of Warm Rain in a Bulk Microphysics Scheme
Improving Simulations of Warm Rain in a Bulk Microphysics Scheme
Abstract
Current bulk microphysical parameterization schemes underpredict precipitation intensities and drop size distributions (DSDs) during warm rain periods, particularly upwind...
A Historical-Theological Understanding of the “Latter Rain”
A Historical-Theological Understanding of the “Latter Rain”
This study is a historical-theological analysis of the understanding of the “Latter Rain” developed in the 19th and 20th centuries. The understanding of the Latter Rain stems from ...
Ura Yilan: The art and science of rain making among the Tiv of central Nigeria
Ura Yilan: The art and science of rain making among the Tiv of central Nigeria
Rain is a natural phenomenon in which showers by means of natural causation down- pours water from the sky for the purpose of moisturing the earth, man, plants and animals for thei...
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Analisa Pengaruh Tegangan Harmonik Terhadap Regulasi Tegangan Eksitasi Generator Satu Fasa
Esensinya setiap generator listrik satu fasa maupun tiga fasa telah dilengkapi dengan sistem eksitasi. Sistem eksitasi generator ada tiga, yaitu sistem eksitasi statis, dinamis, da...