Javascript must be enabled to continue!
Research on the correlation between retinal vascular parameters and axial length in children using an AI-based fundus image analysis system
View through CrossRef
Objective
This study aims to utilize artificial intelligence technology to conduct an in-depth analysis of fundus data from myopic children and adolescents, thoroughly exploring the correlation between retinal vascular parameters and axial length (AL), and ultimately revealing the changing patterns of retinal vascular characteristics in children with different refractive errors. The findings aim to provide a scientific basis for the prevention, early screening, and formulation of personalized treatment strategies for myopia.
Methods
The study selected 124 students from Jiandong Primary School in Changzhi City who underwent myopia prevention and control screening. Their axial length data were recorded, and fundus photographs were taken using the Topcon TNF506 non-mydriatic fundus camera. Subsequently, these fundus images were meticulously analyzed using the EVision AI fundus image analysis system, which is a commercial software that employs pre-trained algorithms to automatically extract retinal vascular parameters.Pearson and Spearman correlation coefficients were used to analyze the correlation between retinal vascular parameters and axial length, and multiple linear regression analysis was further conducted to explore their intrinsic associations.
Results
The study found that in the low myopia group, axial length was significantly negatively correlated with various retinal vascular parameters, including the average diameters of arteries and veins, average vascular tortuosity, atrophy arc area, and leopard spot density. In the moderate to high myopia group, axial length also showed significant negative correlations with the average diameter of arteries, some average venous tortuosity, and average vascular diameter. However, fractal dimension of vessels and average branch angle did not show significant changes across all myopia groups.
Conclusion
This study clearly demonstrates a significant correlation between axial length and retinal vascular parameters, with notable differences in this correlation among children with different refractive errors. These findings not only provide a new perspective for understanding the pathological mechanisms of myopia but also offer important scientific evidence for the development of more precise and personalized myopia prevention and control strategies in the future. They have potential guiding significance for clinical practice and policy formulation.
Public Library of Science (PLoS)
Title: Research on the correlation between retinal vascular parameters and axial length in children using an AI-based fundus image analysis system
Description:
Objective
This study aims to utilize artificial intelligence technology to conduct an in-depth analysis of fundus data from myopic children and adolescents, thoroughly exploring the correlation between retinal vascular parameters and axial length (AL), and ultimately revealing the changing patterns of retinal vascular characteristics in children with different refractive errors.
The findings aim to provide a scientific basis for the prevention, early screening, and formulation of personalized treatment strategies for myopia.
Methods
The study selected 124 students from Jiandong Primary School in Changzhi City who underwent myopia prevention and control screening.
Their axial length data were recorded, and fundus photographs were taken using the Topcon TNF506 non-mydriatic fundus camera.
Subsequently, these fundus images were meticulously analyzed using the EVision AI fundus image analysis system, which is a commercial software that employs pre-trained algorithms to automatically extract retinal vascular parameters.
Pearson and Spearman correlation coefficients were used to analyze the correlation between retinal vascular parameters and axial length, and multiple linear regression analysis was further conducted to explore their intrinsic associations.
Results
The study found that in the low myopia group, axial length was significantly negatively correlated with various retinal vascular parameters, including the average diameters of arteries and veins, average vascular tortuosity, atrophy arc area, and leopard spot density.
In the moderate to high myopia group, axial length also showed significant negative correlations with the average diameter of arteries, some average venous tortuosity, and average vascular diameter.
However, fractal dimension of vessels and average branch angle did not show significant changes across all myopia groups.
Conclusion
This study clearly demonstrates a significant correlation between axial length and retinal vascular parameters, with notable differences in this correlation among children with different refractive errors.
These findings not only provide a new perspective for understanding the pathological mechanisms of myopia but also offer important scientific evidence for the development of more precise and personalized myopia prevention and control strategies in the future.
They have potential guiding significance for clinical practice and policy formulation.
Related Results
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Eyes of Aniso-Axial Length Individuals Share Generally Similar Corneal Biometrics with Normal Eyes in Cataract Population
Aims. To determine the characteristics of corneal biometrics in eyes from aniso-axial length cataract patients compared with eyes from non-aniso-axial length individuals. Methods. ...
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
619. Pharmacokinetic-Pharmacodynamic (PK-PD) Target Attainment Analyses to Support Epetraborole Dose Selection for the Treatment of Patients with Mycobacterium avium Complex (MAC) Lung Disease
Abstract
Background
Epetraborole (EBO) is an orally available, bacterial leucyl transfer RNA synthetase inhibitor that concentra...
e0392 Relationship between retinal vasculopathy and coronary artery disease
e0392 Relationship between retinal vasculopathy and coronary artery disease
Background and objective
Studies showed that atherosclerosis is a systemic disease. Parameters representing peripheral artery atherosclerosis, such as decreased a...
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
LB2306. Population Pharmacokinetic (PPK), Pharmacokinetic/Pharmacodynamic attainment (PTA), and Clinical Pharmacokinetic/Pharmacodynamic (PK/PD) Analyses for Sulbactam-Durlobactam (SUL-DUR) to Support Dose Selection for the Treatment of Acinetobacter baum
Abstract
Background
SUL-DUR is a β-lactam/β-lactamase inhibitor combination in development for the treatment of ABC infections, ...
Axial length as a function of age, sex, and ethnicity: Results from the CLEERE study
Axial length as a function of age, sex, and ethnicity: Results from the CLEERE study
SIGNIFICANCE:
Axial length is emerging as the primary outcome variable used for assessing myopia control efficacy, in both clinic and clinical trials. This repo...
Fundus Bleeding
Fundus Bleeding
Abstract
Fundus bleeding, commonly known as retinal haemorrhage, is a significant ocular manifestation associated with various systemic and ocular conditions. This abstra...
Retinal oximetry in patients with ischaemic retinal diseases
Retinal oximetry in patients with ischaemic retinal diseases
AbstractThe retinal oximeter is a new tool for non‐invasive measurement of retinal oxygen saturation in humans. Several studies have investigated the associations between retinal o...