The Clinical and Economic Impact of Extended Battery Longevity of a Substernal Extravascular Implantable Cardioverter Defibrillator

View through CrossRef
Background and Aims: The extravascular implantable cardioverter defibrillator (EV ICD) has an extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD). This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries . Methods: Battery longevity data were modelled using a Markov model from averages reported in device labelling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability. Clinical demographic data of recipients were derived from published literature. The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy. A one-way sensitivity analysis of the model was performed for the US healthcare system. Results: Average modelled battery longevity was determined to be 7.3 years for the S-ICD compared to 11.8 years for the EV ICD. The probability of a complication after a replacement procedure was 1.4%, with an operative mortality rate of 0.02%. The use of an EV ICD was associated with 1.4-1.6 fewer replacements on average over an expected patient lifetime as compared to an S-ICD and a 24.3-26.0% reduction in cost. The US sensitivity analysis found use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.1-1.6) along with 5-figure cost savings in all scenarios ($18,602-$40,948). Conclusion: The longer projected battery life of the EV ICD compared to the S-ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.
Title: The Clinical and Economic Impact of Extended Battery Longevity of a Substernal Extravascular Implantable Cardioverter Defibrillator
Description:
Background and Aims: The extravascular implantable cardioverter defibrillator (EV ICD) has an extended projected battery longevity compared to the subcutaneous implantable cardioverter defibrillator (S-ICD).
This study used modeling to characterize the need for generator changes, long-term complications, and overall costs for both the EV ICD and S-ICD in healthcare systems of various countries .
Methods: Battery longevity data were modelled using a Markov model from averages reported in device labelling for the S-ICD and with engineering estimates based on real life usage from EV ICD Pivotal Study patient data to introduce variability.
Clinical demographic data of recipients were derived from published literature.
The primary outcomes were defined as the number of generator replacement surgeries, complications, and total healthcare system costs due to battery depletion over the expected lifetime of patients receiving EV ICD or S-ICD therapy.
A one-way sensitivity analysis of the model was performed for the US healthcare system.
Results: Average modelled battery longevity was determined to be 7.
3 years for the S-ICD compared to 11.
8 years for the EV ICD.
The probability of a complication after a replacement procedure was 1.
4%, with an operative mortality rate of 0.
02%.
The use of an EV ICD was associated with 1.
4-1.
6 fewer replacements on average over an expected patient lifetime as compared to an S-ICD and a 24.
3-26.
0% reduction in cost.
The US sensitivity analysis found use of an EV ICD resulted in a reduction in replacement surgeries of greater than 1 (1.
1-1.
6) along with 5-figure cost savings in all scenarios ($18,602-$40,948).
Conclusion: The longer projected battery life of the EV ICD compared to the S-ICD has the potential to meaningfully reduce long-term morbidity and healthcare resources related to generator changes from the perspective of multiple diverse healthcare systems.

Related Results

The effects of age on quality of life in implantable cardioverter defibrillator recipients
The effects of age on quality of life in implantable cardioverter defibrillator recipients
Background.  The implantable cardioverter defibrillator shows superiority over conventional pharmacological therapy. The implantable cardioverter defibrillator has been implanted w...
CT cross‐sectional imaging classification system for substernal goiter based on risk factors for an extracervical surgical approach
CT cross‐sectional imaging classification system for substernal goiter based on risk factors for an extracervical surgical approach
AbstractBackgroundThe purpose of this study was to identify risk factors for surgical extracervical approach in patients with substernal goiter. We used a novel classification syst...
Influence of Albumin on the Extravascular Distribution of Unconjugated Bilirubin
Influence of Albumin on the Extravascular Distribution of Unconjugated Bilirubin
1. [3H]Bilirubin and 131I-labelled albumin were given simultaneously to six healthy adults by intravenous route and the amounts in the plasma were measured for several days. Multic...
Quality of Life and Psychological Status of Patients With Implantable Cardioverter Defibrillators
Quality of Life and Psychological Status of Patients With Implantable Cardioverter Defibrillators
• Background Implantable cardioverter defibrillators reduce mortality in patients at high risk for sudden cardiac death and in patients with heart failure. Patients with defibrilla...
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Peri-Infarct Quantification by Cardiac Magnetic Resonance to Predict Outcomes in Ischemic Cardiomyopathy
Background: In ischemic cardiomyopathy, cardiac magnetic resonance assessment of the peri-infarct zone, a potential substrate for arrhythmogenesis, may serve as a novel...
Large Substernal Thyroid Goiter Associated with Saddle Pulmonary Embolism
Large Substernal Thyroid Goiter Associated with Saddle Pulmonary Embolism
ABSTRACT A 75-year-old woman with a longstanding history of a substernal thyroid goiter presented with acute shortness of breath, and she was intubated due to respiratory distress....
Data-Driven Decision Making in Battery Technology – How to Compete in Global Battery Industry?
Data-Driven Decision Making in Battery Technology – How to Compete in Global Battery Industry?
Battery technology is regarded as a crucial key technology for the energy transition and thus a sustainable future, as batteries can store and distribute renewable energy to cover ...

Back to Top