Topographical corneal edema

View through CrossRef
Abstract. Measurement of the topographical corneal edema response has been previously restricted by the use of optical pachometry and small sample sizes. This study uses ultrasound pachometry to measure changes in the corneal thickness of 23 subjects at 9 locations during 2 hours' wear of a thick soft contact lens. The data are analysed using both averaged and individual location data. The averaged location analysis supports the current paradigm that less edema occurs in the peripheral cornea than in the central cornea during contact lens wear. However, the individual location analysis reveals a more complex corneal edema response in which the greatest amount of edema following 2 hours' contact lens wear occurred in the central and mid‐peripheral temporal cornea, in comparison with the peripheral nasal and peripheral inferior cornea which showed the least edema. The edema measured in the peripheral temporal and peripheral superior cornea following 2 hours' contact lens wear was not significantly different from that measured in the central cornea. The edema measured in the central cornea following 2 hours' contact lens wear was not significantly different from that found at any mid‐peripheral location. This study demonstrates that the corneal edema response associated with 2 hours' wear of a thick soft contact lens is a complex dynamic topographical process and cannot be simply modelled using averaged data from small samples.
Title: Topographical corneal edema
Description:
Abstract.
Measurement of the topographical corneal edema response has been previously restricted by the use of optical pachometry and small sample sizes.
This study uses ultrasound pachometry to measure changes in the corneal thickness of 23 subjects at 9 locations during 2 hours' wear of a thick soft contact lens.
The data are analysed using both averaged and individual location data.
The averaged location analysis supports the current paradigm that less edema occurs in the peripheral cornea than in the central cornea during contact lens wear.
However, the individual location analysis reveals a more complex corneal edema response in which the greatest amount of edema following 2 hours' contact lens wear occurred in the central and mid‐peripheral temporal cornea, in comparison with the peripheral nasal and peripheral inferior cornea which showed the least edema.
The edema measured in the peripheral temporal and peripheral superior cornea following 2 hours' contact lens wear was not significantly different from that measured in the central cornea.
The edema measured in the central cornea following 2 hours' contact lens wear was not significantly different from that found at any mid‐peripheral location.
This study demonstrates that the corneal edema response associated with 2 hours' wear of a thick soft contact lens is a complex dynamic topographical process and cannot be simply modelled using averaged data from small samples.

Related Results

Novel Treatment Options for Corneal Edema
Novel Treatment Options for Corneal Edema
Introduction: The current treatment of corneal edema is limited to hyperosmotic saline mixtures. Usually the therapy consists of treatment with hypertonic 5% NaCl eye drops or 6% e...
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
Surface modification treatments to enhance the performance of titanium backplate in keratoprosthesis
(English) The cornea is the outermost layer of the eye, essential for vision as it provides protection and contributes 80% of the eye’s refractive power. Its transparency and lack ...
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
BackgroundKeratoconus (KC) is an ectatic corneal disorder characterized by progressive corneal thinning with myopic astigmatism. Intrastromal corneal ring segments (ICRS) have been...
Dissociation of Measures of Topographical and Non-topographical Cognitive Ability in Older Adults
Dissociation of Measures of Topographical and Non-topographical Cognitive Ability in Older Adults
The relationship between topographical and non-topographical cognitive measures was studied for 25 elderly participants. The topographical measures were the Camden Topographical Re...
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Effects of TGFB1 and 17 B estradiol on corneal stiffness and thickness
Background: Impaired corneal stiffness and transparency are the hallmarks of some of the leading global causes of corneal blindness diseases, such as keratoconus (KCN) which is cha...
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
Symmetrical femtosecond laser arc incision in correcting corneal astigmatism in cataract patients
AIM: To evaluate the effect of symmetrical arc incision correcting corneal astigmatism in femtosecond laser-assisted phacoemulsification (FLACS). METHODS: This study enrolled patie...
Repeatability and reproducibility of Keratograph 5M corneal topography
Repeatability and reproducibility of Keratograph 5M corneal topography
Background Corneal topography is an important diagnostic tool and highly repeatable and reproducible topographic devices are essential in eye care practice. Placido ...

Back to Top