Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Assessing interference in isobaric tag‐based sample multiplexing using an 18‐plex interference standard

View through CrossRef
AbstractReporter ion interference remains a limitation of isobaric tag‐based sample multiplexing. Advances in instrumentation and data acquisition modes, such as the recently developed real‐time database search (RTS), can reduce interference. However, interference persists as does the need to benchmark upstream sample preparation and data acquisition strategies. Here, we present an updated Triple yeast KnockOut (TKO) standard as well as corresponding upgrades to the TKO viewing tool (TVT2.5, http://tko.hms.harvard.edu/). Specifically, we expand the TKO standard to incorporate the TMTpro18‐plex reagents (TKO18). We also construct a variant thereof which has been digested only with LysC (TKO18L). We compare proteome coverage and interference levels of TKO18 and TKO18L data that are acquired under different data acquisition modes and analyzed using TVT2.5. Our data illustrate that RTS reduces interference while improving proteome coverage and suggest that digesting with LysC alone only modestly reduces interference, albeit at the expense of proteome depth. Collectively, the two new TKO standards coupled with the updated TVT represent a convenient and versatile platform for assessing and developing methods to reduce interference in isobaric tag‐based experiments.
Title: Assessing interference in isobaric tag‐based sample multiplexing using an 18‐plex interference standard
Description:
AbstractReporter ion interference remains a limitation of isobaric tag‐based sample multiplexing.
Advances in instrumentation and data acquisition modes, such as the recently developed real‐time database search (RTS), can reduce interference.
However, interference persists as does the need to benchmark upstream sample preparation and data acquisition strategies.
Here, we present an updated Triple yeast KnockOut (TKO) standard as well as corresponding upgrades to the TKO viewing tool (TVT2.
5, http://tko.
hms.
harvard.
edu/).
Specifically, we expand the TKO standard to incorporate the TMTpro18‐plex reagents (TKO18).
We also construct a variant thereof which has been digested only with LysC (TKO18L).
We compare proteome coverage and interference levels of TKO18 and TKO18L data that are acquired under different data acquisition modes and analyzed using TVT2.
5.
Our data illustrate that RTS reduces interference while improving proteome coverage and suggest that digesting with LysC alone only modestly reduces interference, albeit at the expense of proteome depth.
Collectively, the two new TKO standards coupled with the updated TVT represent a convenient and versatile platform for assessing and developing methods to reduce interference in isobaric tag‐based experiments.

Related Results

Outcomes of plasmapheresis in patients with HLH: A nationwide analysis from 2016–2022
Outcomes of plasmapheresis in patients with HLH: A nationwide analysis from 2016–2022
Abstract Background: Hemophagocytic lymphohistiocytosis (HLH) is a rare but life-threatening hyperinflammatory syndrome ...
PO:37:269 | Intensive therapeutic plasma exchange in life-threatening ANCA-associated vasculitis
PO:37:269 | Intensive therapeutic plasma exchange in life-threatening ANCA-associated vasculitis
Background. In ANCA-associated vasculitis (AAV), despite the findings of the PEXIVAS trial, the usefulness of plasma exchange (PLEX) remains debated in selected clinical settings, ...
Multiplexing of Holograms Based on Spatial Separation
Multiplexing of Holograms Based on Spatial Separation
The analysis of multiplexing methods using spatial separation has been carried out. It is shown that space division multiplexing is possible when there is no Bragg sampling action....
29‐Plex tandem mass tag mass spectrometry enabling accurate quantification by interference correction
29‐Plex tandem mass tag mass spectrometry enabling accurate quantification by interference correction
AbstractTandem mass tag (TMT) mass spectrometry is a mainstream isobaric chemical labeling strategy for profiling proteomes. Here we present a 29‐plex TMT method to combine the 11‐...
Template E-commerce Dinda Wulandari 16011106
Template E-commerce Dinda Wulandari 16011106
1.Tag untuk menentukan tipe dokumen2.Tag ini digunakan untuk membuat Background belakang dari website3.Tag untuk membuat sebuah dokumen HTML4.Tag untuk membuat judul dari sebuah ha...
7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
7 th International Symposium on Enabling Technologies for Life Sciences (ETP)
The seventh in the series of ETP Symposia (see Rapid Communications in Mass Spectrometry 2012, 26 , ...
Measurement of backscattered electric field of chipless radio frequency identification tag based on Rydberg atoms
Measurement of backscattered electric field of chipless radio frequency identification tag based on Rydberg atoms
Chipless radio frequency identification tags have been widely used in many areas, such as vehicle recognition and identification of goods. Near-field measurement of a chipless radi...

Back to Top