Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Mechanical suitability of carbon fiber based composite for chopart prosthetic socket

View through CrossRef
Abstract Material selection has important role in the design of prosthetics. Presently, polyethylene (PE) has been majorly used in the manufacture of chopart prosthetic socket due to it mouldability and low cost, but suffers from large weight to strength ratio. In the present study, carbon fiber composite (CF) is compared with PE for its usability in chopart prosthetic sockets. 3 perlon layers-2 carbon fiber layer-3 perlon layers (3P-2C-3P) lamination was developed and tested for the mechanical properties. Later, the tested mechanical properties of PE and CF were used in finite element modelling to analyze stresses and deformation in the Chopart prosthetic socket. The study showed that use of CF in chopart prosthetic sockets reduces stress by 70.6% as compared to PE, and could be suggested as mechanically superior material in design of chopart prosthetic socket compared to PE.
Title: Mechanical suitability of carbon fiber based composite for chopart prosthetic socket
Description:
Abstract Material selection has important role in the design of prosthetics.
Presently, polyethylene (PE) has been majorly used in the manufacture of chopart prosthetic socket due to it mouldability and low cost, but suffers from large weight to strength ratio.
In the present study, carbon fiber composite (CF) is compared with PE for its usability in chopart prosthetic sockets.
3 perlon layers-2 carbon fiber layer-3 perlon layers (3P-2C-3P) lamination was developed and tested for the mechanical properties.
Later, the tested mechanical properties of PE and CF were used in finite element modelling to analyze stresses and deformation in the Chopart prosthetic socket.
The study showed that use of CF in chopart prosthetic sockets reduces stress by 70.
6% as compared to PE, and could be suggested as mechanically superior material in design of chopart prosthetic socket compared to PE.

Related Results

Lisfranc and Chopart amputation: A systematic review
Lisfranc and Chopart amputation: A systematic review
Background: Lisfranc and Chopart amputations are historically controversial procedures. To obtain evidence for the pros and cons we performed a systematic review to ana...
Dry Socket in Smokers after Odontectomy
Dry Socket in Smokers after Odontectomy
Abstract: Dry socket is delayed healing of a socket resulted from extraction due to the release of blood clot leaving visible bone surface. There are several risk factors of dry so...
Study on friction behavior at the interface between prosthetic socket and liner
Study on friction behavior at the interface between prosthetic socket and liner
Purpose: The friction characteristics at the interface between prosthetic socket and liner have an important influence on the walking function and wearing comfort of amputees. The ...
Advanced engineering materials and materials processing technologies in dental implant and prosthetic treatment with clinical cases
Advanced engineering materials and materials processing technologies in dental implant and prosthetic treatment with clinical cases
The article deals with materials science issues concerning the application areas in dental engineering. The monograph aims to present the results of the Author’s work against the b...
Chopart Joint Injuries: Assessment, Treatment, and 10-Year Results
Chopart Joint Injuries: Assessment, Treatment, and 10-Year Results
Objectives: To investigate injury patterns and long-term outcomes of midtarsal (Chopart) injuries in a sizeable number of patients. ...

Back to Top