Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Entirely anatomical high-power ablation for refractory left ventricular summit arrhythmias

View through CrossRef
Abstract Introduction Ventricular arrhythmias (VA) originating from the left ventricular summit (LVS) can be difficult to eliminate, and outcomes after standard ablation are frequently suboptimal. This study evaluated the safety and effectiveness of entirely anatomical high-power radiofrequency (RF) re-ablation in patients after previously failed LVS VA procedures. Purpose To determine whether an anatomically guided ablation delivered at high-power values can achieve safe and effective elimination of LVS VA in patients after prior unsuccessful ablation. Methods Consecutive patients undergoing re-ablation for symptomatic, drug-refractory LVS arrhythmias were included. Anatomical ablation was performed with high-power values (50-70W) from adjacent structures [coronary cusps, subaortic left ventricular outflow tract (LVOT)]. Concordant dispersive patch position was used in all patients included in the study. Acute success was defined as complete VA elimination during ≥15 minutes of observation, including salbutamol provocation. Results Fifteen patients (12 males; mean age 56 ± 14 years) underwent anatomical re-ablation after 2±2 prior ineffective procedures (range 1–9). The subaortic LVOT was the initial target in 8 patients (53%), while 4 patients (27%) were treated from the coronary cusps. In 3 patients (20%), unipolar applications were delivered both within aortic cusps and the subaortic LVOT. The mean RF time of the unipolar ablation was 291±197 s with a mean power of 53±9 W. Acute PVC elimination was achieved in 7 patients (47%). No complications occurred. During 14±9 months of follow up there was no recurrence of clinically relevant VA in all 7 patients after successful anatomical re-ablation. In those remaining 8 patients (53%) without acute success of entirely anatomical approach, advanced ablation strategies (bipolar ablation, pulsed field ablation, or alcohol ablation) following the anatomical approach were needed. Conclusions Entirely anatomical high-power RF re-ablation of LVS VA is safe and can be effective in significant number of patients after initially failed ablations. Acute effective elimination of clinical LVS VA with presented technique corresponds with good long term outcome. Advanced ablation strategies are still needed in approximately every second patient undergoing repeat LVS VA ablation.
Title: Entirely anatomical high-power ablation for refractory left ventricular summit arrhythmias
Description:
Abstract Introduction Ventricular arrhythmias (VA) originating from the left ventricular summit (LVS) can be difficult to eliminate, and outcomes after standard ablation are frequently suboptimal.
This study evaluated the safety and effectiveness of entirely anatomical high-power radiofrequency (RF) re-ablation in patients after previously failed LVS VA procedures.
Purpose To determine whether an anatomically guided ablation delivered at high-power values can achieve safe and effective elimination of LVS VA in patients after prior unsuccessful ablation.
Methods Consecutive patients undergoing re-ablation for symptomatic, drug-refractory LVS arrhythmias were included.
Anatomical ablation was performed with high-power values (50-70W) from adjacent structures [coronary cusps, subaortic left ventricular outflow tract (LVOT)].
Concordant dispersive patch position was used in all patients included in the study.
Acute success was defined as complete VA elimination during ≥15 minutes of observation, including salbutamol provocation.
Results Fifteen patients (12 males; mean age 56 ± 14 years) underwent anatomical re-ablation after 2±2 prior ineffective procedures (range 1–9).
The subaortic LVOT was the initial target in 8 patients (53%), while 4 patients (27%) were treated from the coronary cusps.
In 3 patients (20%), unipolar applications were delivered both within aortic cusps and the subaortic LVOT.
The mean RF time of the unipolar ablation was 291±197 s with a mean power of 53±9 W.
Acute PVC elimination was achieved in 7 patients (47%).
No complications occurred.
During 14±9 months of follow up there was no recurrence of clinically relevant VA in all 7 patients after successful anatomical re-ablation.
In those remaining 8 patients (53%) without acute success of entirely anatomical approach, advanced ablation strategies (bipolar ablation, pulsed field ablation, or alcohol ablation) following the anatomical approach were needed.
Conclusions Entirely anatomical high-power RF re-ablation of LVS VA is safe and can be effective in significant number of patients after initially failed ablations.
Acute effective elimination of clinical LVS VA with presented technique corresponds with good long term outcome.
Advanced ablation strategies are still needed in approximately every second patient undergoing repeat LVS VA ablation.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
The Case of Kilian Jornet: Factitious Heroism
The Case of Kilian Jornet: Factitious Heroism
| None of the hundreds of millions of people, from May 2017 to the present, who were presented reports that Kilian Jornet reached the summit of Mt. Everest twice in May 2017, unco...
The Case of Kilian Jornet: Factitious Heroism
The Case of Kilian Jornet: Factitious Heroism
| None of the hundreds of millions of people, from May 2017 to the present, who were presented reports that Kilian Jornet reached the summit of Mt. Everest twice in May 2017, unco...
Ventricular Arrhythmias
Ventricular Arrhythmias
Ventricular arrhythmias are common in all forms of heart disease and are an important cause of cardiac arrest and sudden death. Many ventricular arrhythmias are benign but may serv...
Ventricular Arrhythmias
Ventricular Arrhythmias
Ventricular arrhythmias are common in all forms of heart disease and are an important cause of cardiac arrest and sudden death. Many ventricular arrhythmias are benign but may serv...
Abstract 16306: Characteristics of Left Ventricular Summit Ventricular Arrhythmias Ablation - The Inaccessible Peak
Abstract 16306: Characteristics of Left Ventricular Summit Ventricular Arrhythmias Ablation - The Inaccessible Peak
Introduction: Ventricular arrhythmias (VA) arising from the left ventricular (LV summit) are often inaccessible especially in the region superior to the coronary sinus ...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract Introduction  Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Vagus nerve stimulation reduces ventricular arrhythmias and increases ventricular electrical stability
Vagus nerve stimulation reduces ventricular arrhythmias and increases ventricular electrical stability
AbstractBackgroundTranscutaneous stimulation of the auricular branch of the vagus nerve (AB‐VNS) is a potentially noninvasive, inexpensive, and safe approach for vagus nerve stimul...

Back to Top