Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

MANHOLE MANAGEMENT SYSTEM

View through CrossRef
A smart city is the future goal to have cleaner and better amenities for the society. Smart underground infrastructure is an important feature to be considered while implementing a smart city. Drainage system monitoring plays a vital role in keeping the city clean and healthy. Since manual monitoring is incompetent, this leads to slow handling of problems in drainage and consumes more time to solve. To mitigate all these issues, the system using a wireless sensor network, consisting of sensor nodes is designed. The project aims in designing a manhole management system using IOT which alerts the managing station through web page when any manhole crosses its threshold values and also the system monitor the sensors data on LCD module. This system reduces the death risk of manual scavengers who clean the underground drainage and also benefits the public. The project makes a use of water level sensor, water flow sensor, Temperature sensor, Gas sensor and raspberry pi zero w processor. The controlling device of the whole system is raspberry pi processor. In this rise in temperature, explosion due to toxic gases, overflow, manhole lid left open is detected by the sensors. The signals from the sensors are fed to the raspberry pi, which is programmed to generate alerts. In this we use sensors to detect blockage, floods, and gases. The sensors will identify the clogging inside the drainage system and will give information to the user through email and further actions will be taken care by the municipal. Nowadays, accidents due to broken and missing manhole covers are quite frequent. Manholes are not monitored properly in developing countries. These accidents can lead to serious injuries and also death. Hence, here we propose a system to overcome this problem. We have included an array of sensors for complete monitoring of the manhole cover so that such accidents can be prevented. This project includes a gas cover to monitor the gas emitted from the sewage systems so that toxicity can be monitored, the internal temperature is also monitored if a check for a change in the temperature as the property of manhole change with temperature which could need to crack formation, Also, a float sensor is used to indicate when the water level goes beyond a certain level, in case of any alert due to any of the parameters we check on the IOT website. Also, all the parameters are continuously updated on the website.
Title: MANHOLE MANAGEMENT SYSTEM
Description:
A smart city is the future goal to have cleaner and better amenities for the society.
Smart underground infrastructure is an important feature to be considered while implementing a smart city.
Drainage system monitoring plays a vital role in keeping the city clean and healthy.
Since manual monitoring is incompetent, this leads to slow handling of problems in drainage and consumes more time to solve.
To mitigate all these issues, the system using a wireless sensor network, consisting of sensor nodes is designed.
The project aims in designing a manhole management system using IOT which alerts the managing station through web page when any manhole crosses its threshold values and also the system monitor the sensors data on LCD module.
This system reduces the death risk of manual scavengers who clean the underground drainage and also benefits the public.
The project makes a use of water level sensor, water flow sensor, Temperature sensor, Gas sensor and raspberry pi zero w processor.
The controlling device of the whole system is raspberry pi processor.
In this rise in temperature, explosion due to toxic gases, overflow, manhole lid left open is detected by the sensors.
The signals from the sensors are fed to the raspberry pi, which is programmed to generate alerts.
In this we use sensors to detect blockage, floods, and gases.
The sensors will identify the clogging inside the drainage system and will give information to the user through email and further actions will be taken care by the municipal.
Nowadays, accidents due to broken and missing manhole covers are quite frequent.
Manholes are not monitored properly in developing countries.
These accidents can lead to serious injuries and also death.
Hence, here we propose a system to overcome this problem.
We have included an array of sensors for complete monitoring of the manhole cover so that such accidents can be prevented.
This project includes a gas cover to monitor the gas emitted from the sewage systems so that toxicity can be monitored, the internal temperature is also monitored if a check for a change in the temperature as the property of manhole change with temperature which could need to crack formation, Also, a float sensor is used to indicate when the water level goes beyond a certain level, in case of any alert due to any of the parameters we check on the IOT website.
Also, all the parameters are continuously updated on the website.

Related Results

Design and Analysis of Power Screw for Manhole Cover Lifter
Design and Analysis of Power Screw for Manhole Cover Lifter
The importance of manhole in the sewerage system is to get the underground pipelines and alternative systems area unit in good shape. A manhole cover is a detachable plate setting ...
Sustainability Considerations for Underground Concrete Manholes
Sustainability Considerations for Underground Concrete Manholes
Sewer systems enclose one of the harshest environments on concrete materials. These systems if made of concrete are usually accessed for maintenance and inspection by precast concr...
Modeling and Testing of the Sandwich Composite Manhole Cover Designed for Pedestrian Networks
Modeling and Testing of the Sandwich Composite Manhole Cover Designed for Pedestrian Networks
This research concerning the topic, pursues the design, manufacturing, analysis and testing of the manhole cover that may be used in pedestrian networks. Although there are certain...
Connection Between PVC Pipe and Concrete Manhole in Different Schemes
Connection Between PVC Pipe and Concrete Manhole in Different Schemes
Abstract Precast concrete manholes are essential in infrastructure management systems, allowing directional adjustments and connections in the sewerage system and...
Thermomechanical Evaluation of the Performance and Integrity of a HDPE Stub-End Bolted Flange Connection
Thermomechanical Evaluation of the Performance and Integrity of a HDPE Stub-End Bolted Flange Connection
In this study, the integrity of a manhole structure made of a 78 in. high density polyethylene (HDPE) stub-end, steel ring, and blind flange, sealed with a compressed nonasbestos f...
Modeling Urban Flood Inundation and Recession Impacted by Manholes
Modeling Urban Flood Inundation and Recession Impacted by Manholes
Urban flooding, caused by unusually intense rainfall and failure of storm water drainage, has become more frequent and severe in many cities around the world. Most of the earlier s...
Evaluation of the Suitability of Cable Dug Manhole Restoration to Road Conditions in Bandung City
Evaluation of the Suitability of Cable Dug Manhole Restoration to Road Conditions in Bandung City
The development of passive telecommunications infrastructure (IPT) plays an important role in supporting digital transformation and urban spatial planning. However, in Bandung City...
Sprin Journal of Arts, Humanities and Social Sciences
Sprin Journal of Arts, Humanities and Social Sciences
Manhole gases, often hidden underground in cities, can be really harmful to our health. This review looks at all the important aspects of these gases. It starts by talking about th...

Back to Top