Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Simulation of Single Cell Trapping Via Hydrodynamic Manipulation

View through CrossRef
Microfluidic devices are important for the single cell analysis such as cell mechanical and electrical characterization. Single cell characterization could be related to many significant applications including early disease diagnosis. However to perform the single cell manipulation, firstly a single cell have to be isolated and a platform for the cell manipulation have to be provided. One of the methods to trap a single cell is by using hydrodynamic trapping in the microfluidic channel. This study provides a finite element model for single cell trapping for a yeast cell model. The objectives of the simulations are to obtain the appropriate channels’ geometry and optimized ratio of the fluid’s inlet and suction flow rate to trap a single yeast cell. Trap channel was designed to trap a 5μm yeast cell with a suction hole placed in the end of the trap channel. Design geometry and the ratio of fluid flow rates for the cell trapping model were studied using the hydrodynamic resistance concept. The analysis was carried out using numerical solutions from the finite element ABAQUS-FEA software. Using the cell trapping model, a single yeast cell able to be trapped into the trap channel with optimized channel’s suction hole’s geometry and appropriate fluid’s inlet and suction flow rate ratio. The appropriate QTrap/QMain ratio to perform cell trapping using hydrodynamic resistance concept is the ratio value above 1. A 5 μm yeast cell model able to be trap inside a trap channel with the height, width and length of 7 μm by manipulating the suction hole’s flow rate of  1.5 and 2.0 μm of height, 7 and 3 μm of length and width, respectively which situated at the centre edge of the trap channel.
Title: Simulation of Single Cell Trapping Via Hydrodynamic Manipulation
Description:
Microfluidic devices are important for the single cell analysis such as cell mechanical and electrical characterization.
Single cell characterization could be related to many significant applications including early disease diagnosis.
However to perform the single cell manipulation, firstly a single cell have to be isolated and a platform for the cell manipulation have to be provided.
One of the methods to trap a single cell is by using hydrodynamic trapping in the microfluidic channel.
This study provides a finite element model for single cell trapping for a yeast cell model.
The objectives of the simulations are to obtain the appropriate channels’ geometry and optimized ratio of the fluid’s inlet and suction flow rate to trap a single yeast cell.
Trap channel was designed to trap a 5μm yeast cell with a suction hole placed in the end of the trap channel.
Design geometry and the ratio of fluid flow rates for the cell trapping model were studied using the hydrodynamic resistance concept.
The analysis was carried out using numerical solutions from the finite element ABAQUS-FEA software.
Using the cell trapping model, a single yeast cell able to be trapped into the trap channel with optimized channel’s suction hole’s geometry and appropriate fluid’s inlet and suction flow rate ratio.
The appropriate QTrap/QMain ratio to perform cell trapping using hydrodynamic resistance concept is the ratio value above 1.
A 5 μm yeast cell model able to be trap inside a trap channel with the height, width and length of 7 μm by manipulating the suction hole’s flow rate of  1.
5 and 2.
0 μm of height, 7 and 3 μm of length and width, respectively which situated at the centre edge of the trap channel.

Related Results

MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
MARS-seq2.0: an experimental and analytical pipeline for indexed sorting combined with single-cell RNA sequencing v1
Human tissues comprise trillions of cells that populate a complex space of molecular phenotypes and functions and that vary in abundance by 4–9 orders of magnitude. Relying solely ...
Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
A Microfluidic Device for Hydrodynamic Trapping and Manipulation Platform of a Single Biological Cell
A Microfluidic Device for Hydrodynamic Trapping and Manipulation Platform of a Single Biological Cell
To perform specific analysis for the single cell, individual cells have to be captured and separated from each other before further treatments and analysis can be carried out. This...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Comparison of Chemical and Hysteresis CO2 Trapping in the Nugget Formation
Comparison of Chemical and Hysteresis CO2 Trapping in the Nugget Formation
Abstract The Moxa Arch Anticline is a regional-scale northwest-trending uplift in western Wyoming and it has been chosen for CO2 capture and storage. The Nugget Sand...
Optical Fiber Tweezers: A Versatile Tool for Optical Trapping and Manipulation
Optical Fiber Tweezers: A Versatile Tool for Optical Trapping and Manipulation
Optical trapping is widely used in different areas, ranging from biomedical applications, to physics and material sciences. In recent years, optical fiber tweezers have attracted s...
Homogenization design and drag reduction characteristics of hydrodynamic cloaks
Homogenization design and drag reduction characteristics of hydrodynamic cloaks
Hydrodynamic cloaks have attracted extensive attention because of their ability to significantly reduce the surface resistance of designated target. However, most of parameters of ...

Back to Top