The Variable Effective Surface Radiator, Novel Heat Switch Technology Based on the Oscillating Heat Pipe Principle
View through CrossRef
<div class="htmlview paragraph">This paper describes a novel mechanism for heat switch applications in space. The VARiable Effective Surface Radiator (VARES) is a heat switch based on the Oscillating Heat Pipe (OHP) principle. In general all power consuming space objects need radiator surface to radiate surplus of heat. However when switched off the power dissipating objects (electronics) will decrease to unacceptable low temperatures present in space. To overcome this design challenge, several solutions are available such as paraffin heat switches, thermal louvers, and loop heat pipes. Objective of all is to isolate the electronics from the radiator (low temperatures) when switched off. The work described in this paper is performed at NLR on the development of the VARES-radiator for application in spacecraft thermal control systems. The VARES makes use of the property of oscillating heat pipes whereby at low temperatures the oscillation process stops. Therefore it is in principle possible to vary the effective radiator area and thus the power dissipation to the environment. The work presented contains an explanation of the principle of operation in hot and cold conditions, descriptions of performed tests, and VARES breadboards test results. Further it describes design improvements to start the VARES after long cold periods. It is demonstrated that with the right choice of variables (Working fluid and fill charge) an OHP can be used as a heat switch in space applications.</div>
SAE International
Title: The Variable Effective Surface Radiator, Novel Heat Switch Technology Based on the Oscillating Heat Pipe Principle
Description:
<div class="htmlview paragraph">This paper describes a novel mechanism for heat switch applications in space.
The VARiable Effective Surface Radiator (VARES) is a heat switch based on the Oscillating Heat Pipe (OHP) principle.
In general all power consuming space objects need radiator surface to radiate surplus of heat.
However when switched off the power dissipating objects (electronics) will decrease to unacceptable low temperatures present in space.
To overcome this design challenge, several solutions are available such as paraffin heat switches, thermal louvers, and loop heat pipes.
Objective of all is to isolate the electronics from the radiator (low temperatures) when switched off.
The work described in this paper is performed at NLR on the development of the VARES-radiator for application in spacecraft thermal control systems.
The VARES makes use of the property of oscillating heat pipes whereby at low temperatures the oscillation process stops.
Therefore it is in principle possible to vary the effective radiator area and thus the power dissipation to the environment.
The work presented contains an explanation of the principle of operation in hot and cold conditions, descriptions of performed tests, and VARES breadboards test results.
Further it describes design improvements to start the VARES after long cold periods.
It is demonstrated that with the right choice of variables (Working fluid and fill charge) an OHP can be used as a heat switch in space applications.
</div>.
Related Results
Optimized Design of Pipe-in-Pipe Systems
Optimized Design of Pipe-in-Pipe Systems
Abstract
Deepwater subsea developments must address the flow assurance issues and increasingly these are forming a more critical part of the design. Pipe-in-pipe ...
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Cumulative Fatigue Damage of Drill Pipe in Dog-Legs
Abstract
Rotating drill pipe passing through dog-legs suffers fatigue damage due to cyclic bending stresses. Curves of the cumulative fatigue damage incurred in e...
Nanoparticle Size and Heat Pipe Angle Impact on the Thermal Effectiveness of a Cylindrical Screen Mesh Heat Pipe
Nanoparticle Size and Heat Pipe Angle Impact on the Thermal Effectiveness of a Cylindrical Screen Mesh Heat Pipe
This study examines the effects of particle size and heat pipe angle on the thermal effectiveness of a cylindrical screen mesh heat pipe using silver nanoparticles (Ag) as the test...
Implementation and performance evaluation of a pilot‐scaled oscillating heat pipe on rice paddy drying
Implementation and performance evaluation of a pilot‐scaled oscillating heat pipe on rice paddy drying
AbstractThailand is the foremost global producer of rice, benefiting from its hot and humid climate which results in harvested rice with a high moisture content. This promotes the ...
Pipe-in-Pipe Swaged Field Joint for Reel Lay
Pipe-in-Pipe Swaged Field Joint for Reel Lay
Abstract
Subsea 7 and ITP InTerPipe (ITP) have developed a highly efficient Pipe in Pipe technology to be installed by the Reel-Lay method. This solution is based...
The Account of the Effect of Switch Probability on Switch and Mixing Costs: An ERP Study in a Cued Task-switching Paradigm
The Account of the Effect of Switch Probability on Switch and Mixing Costs: An ERP Study in a Cued Task-switching Paradigm
Background:
Whether the effect of switch probability on switch and mixing costs is explained by an activation or preparation account is unclear.
...
“Apparent Net-Section-Collapse” Methodology for Circumferential Surface Flaws in Piping
“Apparent Net-Section-Collapse” Methodology for Circumferential Surface Flaws in Piping
The Original Net-Section-Collapse (NSC) analysis was developed in the 1970s for prediction of the maximum (failure) moment for a pipe with a circumferential flaw, and is used widel...
Clad Steel Pipe for Corrosive Gas Transportation
Clad Steel Pipe for Corrosive Gas Transportation
ABSTRACT
This paper describes the applicability and reliability Of clad steel pipe and its welds in sour gas environments in comparison with those of 22%Cr-5.5%Ni...