A new small volume holding chamber for asthmatic children: Comparison with Babyhaler® spacer

View through CrossRef
When a new holding chamber for administrating inhaled medication is to be marketed, it needs to be compared with existing chambers with two questions in mind: is this chamber well accepted by patients and is there an in vitro equivalence? We compared the new small volume non‐electrostatic valved holding chamber, usable with all pressurized metered‐dose inhalers and equipped with a funny facemask, Vortex® (Pari GmbH, Germany), to the most frequently prescribed holding chamber in France, Babyhaler® (GlaxoSmithKline Laboratories). Preferences were studied for 75 families with a child no more than 4 yr old, using standard questionnaires. An in vitro study assessed the delivered dose and the particle size distribution of two HFA beclomethasone dipropionate pressurized metered dose inhalers (Becotide® 250 μg per dose and Nexxair® 100 μg per dose) by dose uniformity sample apparatus and cascade impactor according to the European Pharmacopoeia. Vortex® was preferred by 95% of the families because of its small size, its duck facemask, and its robust appearance. Among children able to give their opinion, 86% preferred Vortex® to Babyhaler®. In vitro, both holding chambers reduced the delivered dose of beclomethasone dipropionate and increased the quantity of particles smaller than 5 μm in diameter with both medications. A higher proportion of fine particles was obtained with Nexxair® than with Becotide® (p < 0.05) and with Vortex® than with Babyhaler® (p < 0.05). As expected, throat deposition is dramatically reduced for both drugs with both holding chambers. The in vitro difference in the particle size distribution of beclomethasone dipropionate with both holding chambers probably has no clinical influence.
Title: A new small volume holding chamber for asthmatic children: Comparison with Babyhaler® spacer
Description:
When a new holding chamber for administrating inhaled medication is to be marketed, it needs to be compared with existing chambers with two questions in mind: is this chamber well accepted by patients and is there an in vitro equivalence? We compared the new small volume non‐electrostatic valved holding chamber, usable with all pressurized metered‐dose inhalers and equipped with a funny facemask, Vortex® (Pari GmbH, Germany), to the most frequently prescribed holding chamber in France, Babyhaler® (GlaxoSmithKline Laboratories).
Preferences were studied for 75 families with a child no more than 4 yr old, using standard questionnaires.
An in vitro study assessed the delivered dose and the particle size distribution of two HFA beclomethasone dipropionate pressurized metered dose inhalers (Becotide® 250 μg per dose and Nexxair® 100 μg per dose) by dose uniformity sample apparatus and cascade impactor according to the European Pharmacopoeia.
Vortex® was preferred by 95% of the families because of its small size, its duck facemask, and its robust appearance.
Among children able to give their opinion, 86% preferred Vortex® to Babyhaler®.
In vitro, both holding chambers reduced the delivered dose of beclomethasone dipropionate and increased the quantity of particles smaller than 5 μm in diameter with both medications.
A higher proportion of fine particles was obtained with Nexxair® than with Becotide® (p < 0.
05) and with Vortex® than with Babyhaler® (p < 0.
05).
As expected, throat deposition is dramatically reduced for both drugs with both holding chambers.
The in vitro difference in the particle size distribution of beclomethasone dipropionate with both holding chambers probably has no clinical influence.

Related Results

Respiratory muscle strength in asthmatic children
Respiratory muscle strength in asthmatic children
Introduction: Changes in the respiratory system of asthmatics are also due to the mechanical disadvantage caused by the increased airway resistance. Objective: The stud...
Bacterial Contamination of Spacer Devices Used by Asthmatic Children
Bacterial Contamination of Spacer Devices Used by Asthmatic Children
Purpose of the Study. To investigate bacterial contamination in spacer devices used by asthmatic children and the device-maintenance procedures practiced by paren...
Dyslipidemia Associates with Respiratory Resistance Assessed by Forced Oscillation Technique in Asthmatic Children
Dyslipidemia Associates with Respiratory Resistance Assessed by Forced Oscillation Technique in Asthmatic Children
Abstract Purpose: This study evaluated the correlation between dyslipidemia and pulmonary function parameters assessed by spirometry and force oscillation technique in asth...
Comparison of Caries Experience of Asthmatic and Non-Asthmatic Children in Enugu, Nigeria
Comparison of Caries Experience of Asthmatic and Non-Asthmatic Children in Enugu, Nigeria
Background: Asthma and dental caries are two most common chronic diseases among children. The aim of the present study was to determine and compare the dental caries experience bet...
Improving Cementing Efficiency by Optimizing the Spacer Train: Case Histories
Improving Cementing Efficiency by Optimizing the Spacer Train: Case Histories
Abstract After a time-consuming cement squeeze to improve zonal isolation in a southern Nigeria well, engineers returned to the laboratory for a means to ensure prim...

Back to Top