Investigation of Spray Cooling Schemes for Dynamic Thermal Management

View through CrossRef
This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems. Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency. Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling. Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle. HFE-7100 dielectric liquid is selected as the working fluid. Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices. The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 μm thick copper-based coating prepared by dual stage electroplating technique. Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and ~10°C subcooling. Steady flow spray cooling tests are conducted at flow rates of 2 - 5 ml/cm².s, by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves in the form of surface superheat vs. heat flux. Variable flow and intermittent flow spray cooling tests are done at selected flowrate and subcooling conditions to investigate the effects of dynamic flow conditions on maintaining the target surface temperatures defined based on reference steady flow spray cooling performance.
University of North Texas Libraries
Title: Investigation of Spray Cooling Schemes for Dynamic Thermal Management
Description:
This study aims to investigate variable flow and intermittent flow spray cooling characteristics for efficiency improvement in active two-phase thermal management systems.
Variable flow spray cooling scheme requires control of pump input voltage (or speed), while intermittent flow spray cooling scheme requires control of solenoid valve duty cycle and frequency.
Several testing scenarios representing dynamic heat load conditions are implemented to characterize the overall performance of variable flow and intermittent flow spray cooling cases in comparison with the reference, steady flow spray cooling case with constant flowrate, continuous spray cooling.
Tests are conducted on a small-scale, closed loop spray cooling system featuring a pressure atomized spray nozzle.
HFE-7100 dielectric liquid is selected as the working fluid.
Two types of test samples are prepared on 10 mm x 10 mm x 2 mm copper substrates with matching size thick film resistors attached onto the opposite side, to generate heat and simulate high heat flux electronic devices.
The test samples include: (i) plain, smooth surface, and (ii) microporous surface featuring 100 μm thick copper-based coating prepared by dual stage electroplating technique.
Experimental conditions involve HFE-7100 at atmospheric pressure and 30°C and ~10°C subcooling.
Steady flow spray cooling tests are conducted at flow rates of 2 - 5 ml/cm².
s, by controlling the heat flux in increasing steps, and recording the corresponding steady-state temperatures to obtain cooling curves in the form of surface superheat vs.
heat flux.
Variable flow and intermittent flow spray cooling tests are done at selected flowrate and subcooling conditions to investigate the effects of dynamic flow conditions on maintaining the target surface temperatures defined based on reference steady flow spray cooling performance.

Related Results

Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
An Experimental Investigation on the Spray Characteristics of Dimethyl Ether(DME)
An Experimental Investigation on the Spray Characteristics of Dimethyl Ether(DME)
<div class="htmlview paragraph">A series of tests were conducted using scattered laser light photography to study the spray characteristics of DME and diesel fuel. The photog...
Optimisation of Spraying Parameters for Boom Sprayers
Optimisation of Spraying Parameters for Boom Sprayers
In order to investigate the influence of factors on the spray deposition of the spray bar sprayer, using the designed mobile spray bar spray device, the spray height, spray bar tra...
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Application of Machine Learning Based Meta Models for Predicting Film Cooling Effectiveness in Gas Turbine Blades
Abstract In Large Gas Turbines, turbine components in particular blades and vanes operate at significantly high temperatures. As a result, cooling of these component...
Spray Cooling as a High-Efficient Thermal Management Solution: A Review
Spray Cooling as a High-Efficient Thermal Management Solution: A Review
As one of the most promising thermal management solutions, spray cooling has the advantages of high heat-transfer coefficient and maintaining a low temperature of the cooling surfa...
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Selective Head Cooling in Newborn Infants After Perinatal Asphyxia: A Safety Study
Aims.To determine the practicality and safety of head cooling with mild or minimal systemic hypothermia in term neonates with moderate to severe hypoxic-ischemic encephalopathy.Met...
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Effect of non-isothermality on film cooling effectiveness under partial blockage of coolant injection holes
Modern gas turbine units (GTUs) operate at extremely high temperatures, with mainstream gas temperatures reaching 1700–1750 °C in transport and military applications, while heat-re...