Javascript must be enabled to continue!
Naturally Occurring Montmorillonite-Based Polymer Monolith Composites as Stationary Phases for Capillary Liquid and Gas Chromatography
View through CrossRef
This work is associated with the preparation of capillary chromatographic columns containing inorganic-organic composites comprised of naturally occurring montmorillonite (MMT) clay mineral and polymethacrylate monolithic material. The prepared composites combine the best qualities of both constituents, offering desirable properties for use under the disparate conditions of both GC and HPLC at the same time. The stationary phases were investigated by scanning electron microscopy (SEM), the specific surface area, and thermogravimetric analysis (TGA) and examined in terms of various conditions utilized for GC and HPLC methods. The prepared columns demonstrated an excellent permeability and stability against common chromatographic conditions, such as the eluent type, flow rate, pressure, and temperature. The results confirmed that the addition of small amounts of MMT into the monolith induced significant improvement in the specific surface area, which contributed to the formation of more active sites and enhanced the retention of analytes. The registered column backpressures did not exceed 980 kPa and 16,500 kPa for the prepared GC and HPLC columns, respectively. The prepared columns were subjected to the separation of various interesting compounds possessing different chemistries and polarities, including alkanes, alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs), alcohols, ketones, phenols, some common organic solvents, and isomeric mixtures. Under the optimal conditions, the efficiency of the columns fell between 4900–38,500 plates m−1 for GC and 3400–58,800 plates m−1 for capillary HPLC applications. In all cases, the measured chromatographic resolution was more than 1.38, with excellent an peak symmetry and low tailing factors. In comparison with the most commonly used commercial columns, the polysiloxane open tubular column for GC and silica-based C18 packed column for HPLC, the prepared GC columns demonstrated a faster separation with a higher efficiency, comparable resolution and tailing factors, and lower consumption of carrier gas. Regarding the capillary columns prepared for HPLC, the chromatographic experiments exposed a much lower run time with a comparable efficiency and resolution and drastically lower consumption of mobile phase solvents and samples. The results demonstrate that the MMT-based polymethacrylate monolith composites are applicable as novel and promising separation media for analyzing various mixtures of interest in different fields, such as petrochemical and environmental samples.
Title: Naturally Occurring Montmorillonite-Based Polymer Monolith Composites as Stationary Phases for Capillary Liquid and Gas Chromatography
Description:
This work is associated with the preparation of capillary chromatographic columns containing inorganic-organic composites comprised of naturally occurring montmorillonite (MMT) clay mineral and polymethacrylate monolithic material.
The prepared composites combine the best qualities of both constituents, offering desirable properties for use under the disparate conditions of both GC and HPLC at the same time.
The stationary phases were investigated by scanning electron microscopy (SEM), the specific surface area, and thermogravimetric analysis (TGA) and examined in terms of various conditions utilized for GC and HPLC methods.
The prepared columns demonstrated an excellent permeability and stability against common chromatographic conditions, such as the eluent type, flow rate, pressure, and temperature.
The results confirmed that the addition of small amounts of MMT into the monolith induced significant improvement in the specific surface area, which contributed to the formation of more active sites and enhanced the retention of analytes.
The registered column backpressures did not exceed 980 kPa and 16,500 kPa for the prepared GC and HPLC columns, respectively.
The prepared columns were subjected to the separation of various interesting compounds possessing different chemistries and polarities, including alkanes, alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs), alcohols, ketones, phenols, some common organic solvents, and isomeric mixtures.
Under the optimal conditions, the efficiency of the columns fell between 4900–38,500 plates m−1 for GC and 3400–58,800 plates m−1 for capillary HPLC applications.
In all cases, the measured chromatographic resolution was more than 1.
38, with excellent an peak symmetry and low tailing factors.
In comparison with the most commonly used commercial columns, the polysiloxane open tubular column for GC and silica-based C18 packed column for HPLC, the prepared GC columns demonstrated a faster separation with a higher efficiency, comparable resolution and tailing factors, and lower consumption of carrier gas.
Regarding the capillary columns prepared for HPLC, the chromatographic experiments exposed a much lower run time with a comparable efficiency and resolution and drastically lower consumption of mobile phase solvents and samples.
The results demonstrate that the MMT-based polymethacrylate monolith composites are applicable as novel and promising separation media for analyzing various mixtures of interest in different fields, such as petrochemical and environmental samples.
Related Results
Chromatography, Liquid
Chromatography, Liquid
AbstractThis article describes the modern practice of analytical high performance liquid chromatography (HPLC). Liquid chromatography involves the separation of compounds by differ...
Simulation of mechanical properties based on microstructure in polyethylene/montmorillonite nanocomposites
Simulation of mechanical properties based on microstructure in polyethylene/montmorillonite nanocomposites
In order to explore the microscopic mechanism of mechanical properties in polyethylene/montmorillonite (PE/MMT) nanocomposite material,the molecular model and the molecule structur...
The capillary fascicle in skeletal muscle: Structural and functional physiology of RBC distribution in capillary networks
The capillary fascicle in skeletal muscle: Structural and functional physiology of RBC distribution in capillary networks
Key points
The capillary module, consisting of parallel capillaries from arteriole to venule, is classically considered as the building block of complex capillary networks. In skel...
Principles of Three Phase Capillary Pressures
Principles of Three Phase Capillary Pressures
Abstract
In porous media, there are a variety of configurations in which three immiscible fluids can be distributed within a single body. For example, the fluids ...
A New Displacement Capillary Pressure Model
A New Displacement Capillary Pressure Model
Abstract
A capillary pressure function for porous media (commonly known as the J-function) was postulated by Leverett and has been widely used for correlation pur...
Capillary Number Correlations for Gas-Liquid Systems
Capillary Number Correlations for Gas-Liquid Systems
Abstract
Conventional Capillary Number theory predicts that residual oil will not be mobilized until a critical capillary number (2E-05) is exceeded. This theory ...
Principles of Three-phase Capillary Pressures
Principles of Three-phase Capillary Pressures
Abstract
In porous media, there are a variety of configurations in which threeimmiscible fluids can be distributed within a single body. For example, thefluids ma...
Smectite-water exchanges at the Ceres crust
Smectite-water exchanges at the Ceres crust
Dawn mission sensors detected pervasive Mg and NH4 phyllosilicates mixed with a dark mineral component, probably magnetite, on Ceres’ surface, and observed Na and Mg carb...

