Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

MO‐E‐330A‐06: Cone Beam CT (CBCT) Image Fusion for Prostate Localization: Interobserver Variability Study Using Manual and Automatic Registration

View through CrossRef
Purpose: Applying manual registration of CBCT to a reference image for prostate localization increases treatment time affecting prostate motion and patient setup. A reliable automatic registration can be more time efficient and accurate. This preliminary study demonstrates variability of manual fusion by multiple observers comparing manual to an in‐house automatic fusion. Methods and Materials: 7 patients with 7 CBCT scans each were studied by 4 observers. Off‐line manual fusion between CBCT and Simulation CT was performed using On‐Board Imaging (OBI) software by Varian version 1.2. We pre‐defined our Region of Interest (ROI) and Organ of Interest (OOI) to be the pelvic bones and the prostate respectively. Offsets were recorded in 4 degrees of freedom (3 translations and couch rotation). To increase precision, one outlier observation was excluded. Interobserver variation in manual registration was studied by determining percentage of observations that fall within 1 mm and 1 degree standard deviation (SD). Automatic registration, utilizing the uphill simplex, gradient correlation and mutual information similarity measures, was compared to the manual matched results using frequency histograms of the differences between the two methods. System robustness is checked using prostate calcifications. Results: Comparing different observers, 69% cranial‐caudal (C‐C), 83% anterior‐posterior (A‐P), 100% right‐left (R‐L), and 100% (couch rotation) of the observations fall within 1 mm,1 degree SD for ROI. 69% C‐C, 75% A‐P, 90% R‐L, and 100% couch rotation were observed for OOI. ROI/OOI automatic fusion showed 92%/85% overall agreement with manual fusion within 2 mm respectively. Conclusion: Manual registration is time consuming and demonstrates observers' variations. The automatic method localizes the prostate within 15 seconds. More observers and measurements, methods utilizing drawn contours and implanted fiducial markers, will be required for system accuracy and precision. Our automatic registration with feed back from observers' experiences would enable on‐line correction for prostate motion.
Title: MO‐E‐330A‐06: Cone Beam CT (CBCT) Image Fusion for Prostate Localization: Interobserver Variability Study Using Manual and Automatic Registration
Description:
Purpose: Applying manual registration of CBCT to a reference image for prostate localization increases treatment time affecting prostate motion and patient setup.
A reliable automatic registration can be more time efficient and accurate.
This preliminary study demonstrates variability of manual fusion by multiple observers comparing manual to an in‐house automatic fusion.
Methods and Materials: 7 patients with 7 CBCT scans each were studied by 4 observers.
Off‐line manual fusion between CBCT and Simulation CT was performed using On‐Board Imaging (OBI) software by Varian version 1.
2.
We pre‐defined our Region of Interest (ROI) and Organ of Interest (OOI) to be the pelvic bones and the prostate respectively.
Offsets were recorded in 4 degrees of freedom (3 translations and couch rotation).
To increase precision, one outlier observation was excluded.
Interobserver variation in manual registration was studied by determining percentage of observations that fall within 1 mm and 1 degree standard deviation (SD).
Automatic registration, utilizing the uphill simplex, gradient correlation and mutual information similarity measures, was compared to the manual matched results using frequency histograms of the differences between the two methods.
System robustness is checked using prostate calcifications.
Results: Comparing different observers, 69% cranial‐caudal (C‐C), 83% anterior‐posterior (A‐P), 100% right‐left (R‐L), and 100% (couch rotation) of the observations fall within 1 mm,1 degree SD for ROI.
69% C‐C, 75% A‐P, 90% R‐L, and 100% couch rotation were observed for OOI.
ROI/OOI automatic fusion showed 92%/85% overall agreement with manual fusion within 2 mm respectively.
Conclusion: Manual registration is time consuming and demonstrates observers' variations.
The automatic method localizes the prostate within 15 seconds.
More observers and measurements, methods utilizing drawn contours and implanted fiducial markers, will be required for system accuracy and precision.
Our automatic registration with feed back from observers' experiences would enable on‐line correction for prostate motion.

Related Results

Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations
Comparing Unet training with three different datasets to correct CBCT images for prostate radiotherapy dose calculations
Abstract Image intensity correction is crucial to enable cone beam computed tomography (CBCT) based radiotherapy dose calculations. This study evaluated three dif...
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Comparison between hybrid CBCT and CBCT in detection of vertical root fracture
Cone beam computerized tomography (CBCT) has been wildly used in many fields of dentistry, especially to investigate the vertical root fracture (VRF). CBCT systems were consisted o...
Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images
Evaluation of manual and automatic segmentation of the mouse heart from CINE MR images
AbstractPurposeTo compare global functional parameters determined from a stack of cinematographic MR images of mouse heart by a manual segmentation and an automatic segmentation al...
Evaluation of a novel CBCT conversion method implemented in a treatment planning system
Evaluation of a novel CBCT conversion method implemented in a treatment planning system
Abstract Background To evaluate a novel CBCT conversion algorithm for dose calculation implemented in a research version ...
Barriers Toward Better CBCT Knowledge, Attitude, and Practice
Barriers Toward Better CBCT Knowledge, Attitude, and Practice
Objective: This study attempts to evaluate the knowledge, attitude, and clinical practice of Iraqi dentists toward CBCT use, referral patterns, observed challenges, and the impacts...
The Nuclear Fusion Award
The Nuclear Fusion Award
The Nuclear Fusion Award ceremony for 2009 and 2010 award winners was held during the 23rd IAEA Fusion Energy Conference in Daejeon. This time, both 2009 and 2010 award winners w...
Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
Radiographic imaging in relation to the mandibular third molar: tooth characteristics, modality choice, optimization, and absorbed dose
Radiographic imaging of the mandibular third molar (M3) is a valuable diagnostic tool. It provides information on tooth position, root morphology, and relations to surrounding anat...

Back to Top