Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Sensor-augmented CSII therapy with predictive low-glucose suspend following total pancreatectomy

View through CrossRef
Pancreatogenic diabetes is characterised by recurrent severe hypoglycaemia due to changes in both endocrine and exocrine functions. There are no guidelines to manage these individuals. Herein, we describe the post-operative management of two people who developed pancreatogenic diabetes following total pancreatectomy for neuroendocrine malignancy. In both individuals, diabetes was managed using sensor-augmented predictive low-glucose suspend continuous subcutaneous insulin infusion (CSII). We demonstrate the benefit of sensor-augmented CSII in averting hypoglycaemia whilst optimising glycaemic control. Expected rates of severe hypoglycaemia in individuals with pancreatogenic diabetes can be averted with the use of continuous glucose monitoring (CGM) technology, optimising quality of life and reducing the risk of diabetes-related complications. Learning points: There are no clear guidelines to manage people with pancreatogenic diabetes. We describe the use of CGM with predictive low-glucose suspend continuous subcutaneous insulin infusion (CSII) in the management of two individuals post-pancreatectomy. Predictive low-glucose suspend technology can achieve excellent glycaemic control whilst avoiding recurrent and severe hypoglycaemia in people with pancreatogenic diabetes. Predictive low-glucose suspend CGM should be considered as an effective therapeutic option for the management of pancreatogenic diabetes.
Title: Sensor-augmented CSII therapy with predictive low-glucose suspend following total pancreatectomy
Description:
Pancreatogenic diabetes is characterised by recurrent severe hypoglycaemia due to changes in both endocrine and exocrine functions.
There are no guidelines to manage these individuals.
Herein, we describe the post-operative management of two people who developed pancreatogenic diabetes following total pancreatectomy for neuroendocrine malignancy.
In both individuals, diabetes was managed using sensor-augmented predictive low-glucose suspend continuous subcutaneous insulin infusion (CSII).
We demonstrate the benefit of sensor-augmented CSII in averting hypoglycaemia whilst optimising glycaemic control.
Expected rates of severe hypoglycaemia in individuals with pancreatogenic diabetes can be averted with the use of continuous glucose monitoring (CGM) technology, optimising quality of life and reducing the risk of diabetes-related complications.
Learning points: There are no clear guidelines to manage people with pancreatogenic diabetes.
We describe the use of CGM with predictive low-glucose suspend continuous subcutaneous insulin infusion (CSII) in the management of two individuals post-pancreatectomy.
Predictive low-glucose suspend technology can achieve excellent glycaemic control whilst avoiding recurrent and severe hypoglycaemia in people with pancreatogenic diabetes.
Predictive low-glucose suspend CGM should be considered as an effective therapeutic option for the management of pancreatogenic diabetes.

Related Results

Continuous subcutaneous insulin infusion (CSII) 30 years later: still the best option for insulin therapy
Continuous subcutaneous insulin infusion (CSII) 30 years later: still the best option for insulin therapy
AbstractThirty years after its introduction, the use of continuous subcutaneous insulin infusion (CSII) keeps increasing, especially among children and adolescents. The technique, ...
Does the Introduction of Laparoscopic Distal Pancreatectomy Jeopardize Patient Safety and Well-Being?
Does the Introduction of Laparoscopic Distal Pancreatectomy Jeopardize Patient Safety and Well-Being?
Background/Purpose: Despite retrospective data indicating short-term superiority for laparoscopic distal pancreatectomy compared to open distal pancreatectomy, ...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Continuous subcutaneous insulin infusion leads to immediate, stable and long‐term changes in metabolic control
Continuous subcutaneous insulin infusion leads to immediate, stable and long‐term changes in metabolic control
Background:  Evaluations of continuous subcutaneous insulin infusion (CSII) usually focus on one pre‐ and one post‐CSII measurement to assess metabolic therapy ...
HPB SO15 - Developing protocol for managing diabetes after Distal pancreatectomy
HPB SO15 - Developing protocol for managing diabetes after Distal pancreatectomy
Abstract Background The incidence of new-onset diabetes mellitus (NODM) has been reported to be 18% to 39% after pancreaticoduod...

Back to Top