Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Mapping Perfusion and Predicting Success: Infrared Thermography-Guided Perforator Flaps for Lower Limb Defects

View through CrossRef
Background and Objectives: Lower limb defects often present significant reconstructive challenges due to limited soft tissue availability and exposure of critical structures. Perforator-based flaps offer reliable solutions, with minimal donor site morbidity. This study aimed to evaluate the efficacy of infrared thermography (IRT) in preoperative planning and postoperative monitoring of perforator-based flaps, assessing its accuracy in identifying perforators, predicting complications, and optimizing outcomes. Materials and Methods: A prospective observational study was conducted on 76 patients undergoing lower limb reconstruction with fascio-cutaneous perforator flaps between 2022 and 2024. Perforator mapping was performed concurrently with IRT and Doppler ultrasonography (D-US), with intraoperative confirmation. Flap design variables and systemic parameters were recorded. Postoperative monitoring employed thermal imaging on days 1 and 7. Outcomes were correlated with thermal, anatomical, and systemic factors using statistical analyses, including t-tests and Pearson correlation. Results: IRT showed high sensitivity (97.4%) and positive predictive value (96.8%) for perforator detection. A total of nine minor complications occurred, predominantly in patients with diabetes mellitus and/or elevated glycemia (p = 0.05). Larger flap-to-defect ratios (A/C and B/C) correlated with increased complications in propeller flaps, while smaller ratios posed risks for V-Y and Keystone flaps. Thermal analysis indicated significantly lower flap temperatures and greater temperature gradients in flaps with complications by postoperative day 7 (p < 0.05). CRP levels correlated with glycemia and white blood cell counts, highlighting systemic inflammation’s impact on outcomes. Conclusions: IRT proves to be a reliable, non-invasive method for perforator localization and flap monitoring, enhancing surgical planning and early complication detection. Combined with D-US, it improves perforator selection and perfusion assessment. Thermographic parameters, systemic factors, and flap design metrics collectively predict flap viability. Integration of IRT into surgical workflows offers a cost-effective tool for optimizing reconstructive outcomes in lower limb surgery.
Title: Mapping Perfusion and Predicting Success: Infrared Thermography-Guided Perforator Flaps for Lower Limb Defects
Description:
Background and Objectives: Lower limb defects often present significant reconstructive challenges due to limited soft tissue availability and exposure of critical structures.
Perforator-based flaps offer reliable solutions, with minimal donor site morbidity.
This study aimed to evaluate the efficacy of infrared thermography (IRT) in preoperative planning and postoperative monitoring of perforator-based flaps, assessing its accuracy in identifying perforators, predicting complications, and optimizing outcomes.
Materials and Methods: A prospective observational study was conducted on 76 patients undergoing lower limb reconstruction with fascio-cutaneous perforator flaps between 2022 and 2024.
Perforator mapping was performed concurrently with IRT and Doppler ultrasonography (D-US), with intraoperative confirmation.
Flap design variables and systemic parameters were recorded.
Postoperative monitoring employed thermal imaging on days 1 and 7.
Outcomes were correlated with thermal, anatomical, and systemic factors using statistical analyses, including t-tests and Pearson correlation.
Results: IRT showed high sensitivity (97.
4%) and positive predictive value (96.
8%) for perforator detection.
A total of nine minor complications occurred, predominantly in patients with diabetes mellitus and/or elevated glycemia (p = 0.
05).
Larger flap-to-defect ratios (A/C and B/C) correlated with increased complications in propeller flaps, while smaller ratios posed risks for V-Y and Keystone flaps.
Thermal analysis indicated significantly lower flap temperatures and greater temperature gradients in flaps with complications by postoperative day 7 (p < 0.
05).
CRP levels correlated with glycemia and white blood cell counts, highlighting systemic inflammation’s impact on outcomes.
Conclusions: IRT proves to be a reliable, non-invasive method for perforator localization and flap monitoring, enhancing surgical planning and early complication detection.
Combined with D-US, it improves perforator selection and perfusion assessment.
Thermographic parameters, systemic factors, and flap design metrics collectively predict flap viability.
Integration of IRT into surgical workflows offers a cost-effective tool for optimizing reconstructive outcomes in lower limb surgery.

Related Results

Using Superiorly Located Perforator-Based Parasacral Perforator Flaps for Reconstruction of Sacral Defects
Using Superiorly Located Perforator-Based Parasacral Perforator Flaps for Reconstruction of Sacral Defects
Objective: Despite the advances, reconstruction of the sacral region remains a challenge due to the nature of this area. Parasacral perforator flaps can be useful for small to mode...
Unconventional Perfusion Flaps in the Experimental Setting: A Systematic Review and Meta-Analysis
Unconventional Perfusion Flaps in the Experimental Setting: A Systematic Review and Meta-Analysis
Background: Unconventional perfusion flaps offer multiple potential advantages compared with traditional flaps. Although there are numerous experimental articles on unc...
Perforator-based flaps for the treatment of burn scar contractures: a review
Perforator-based flaps for the treatment of burn scar contractures: a review
Abstract Patients with burn scars often experience functional problems because of scar contractures. Surgical treatment may be indicated for those burn scar contract...
Perforator flaps based on the deltoid branch of the thoracoacromial artery: anatomical study
Perforator flaps based on the deltoid branch of the thoracoacromial artery: anatomical study
Objectives: Tissue defects in the lateral triangle of the neck and the anterior cervical region represent a high demand for plastic and reconstructive surgery. Their management mos...
Advances in medical infrared thermography
Advances in medical infrared thermography
[EMBARGOED UNTIL 6/1/2023] The association between illness and body temperature dates back to the beginnings of medicine. Over the last few years, infrared thermography has attract...
Mapping 216 Perforator Flaps Using Highly Portable Tablet-Based Color Doppler Ultrasound (PT-CDU)
Mapping 216 Perforator Flaps Using Highly Portable Tablet-Based Color Doppler Ultrasound (PT-CDU)
Abstract Background The first reports of using color Doppler ultrasound for evaluation of the microvasculature were in the 1990s. Despite the early reports of its efficac...

Back to Top