Javascript must be enabled to continue!
Validation of a blood gas device for ionized calcium analysis in Holstein cows
View through CrossRef
AbstractBackgroundAccurate analysis of ionized calcium (iCa) is critical for the detection of hypocalcemia or subclinical hypocalcemia. The Edan i15 Vet (EDAN) blood gas device has not been validated for iCa in dairy cows.ObjectivesWe aimed to validate the EDAN blood gas device against the Gem Premier 3000 (GEM) analyzer by measuring iCa concentrations and evaluating the ability of these measurements, compared with serum total calcium (TCa) concentrations, to diagnose subclinical hypocalcemia.MethodsiCa concentrations were measured with the EDAN and GEM devices, and serum TCa concentrations were measured with a wet biochemistry method with blood from 125 lactating Holstein cows between calving to day 27 postpartum.ResultsBland‐Altman plots showed a mean and total bias of 0.05 and 0.24 mmol/L for the EDAN device, respectively. The intercept did not include zero, but the slope included 1.0 in the Passing‐Bablok regression. The sensitivity and specificity (Se/Sp) of the EDAN device were 93/94%, 93/90%, 91/93%, and 85/95% for iCa cut‐off values of <1.00, 1.05, 1.10, and 1.15 mmol/L, respectively, as determined with the GEM device. The Se/Sp were 57/82% and 72/80% for EDAN and 57/80% and 72/79% for GEM at serum TCa cut‐off points <2.15 and <2.00 mmol/L, respectively. The average iCa concentrations analyzed with the GEM and EDAN devices were 1.04 ± 0.18 and 1.09 ± 0.17, respectively.ConclusionsThe EDAN device did not have satisfactory agreement with GEM and could not be used interchangeably, but it had satisfactory Se/Sp to diagnose subclinical hypocalcemia compared with the GEM‐derived iCa cut‐off points. Serum TCa concentration cut‐off values were not suitable for diagnosing subclinical hypocalcemia because of unsatisfactory Se/Sp compared with iCa concentrations analyzed by the GEM and EDAN devices. The iCa values analyzed using the EDAN and GEM devices were consistent with previously reported data.
Title: Validation of a blood gas device for ionized calcium analysis in Holstein cows
Description:
AbstractBackgroundAccurate analysis of ionized calcium (iCa) is critical for the detection of hypocalcemia or subclinical hypocalcemia.
The Edan i15 Vet (EDAN) blood gas device has not been validated for iCa in dairy cows.
ObjectivesWe aimed to validate the EDAN blood gas device against the Gem Premier 3000 (GEM) analyzer by measuring iCa concentrations and evaluating the ability of these measurements, compared with serum total calcium (TCa) concentrations, to diagnose subclinical hypocalcemia.
MethodsiCa concentrations were measured with the EDAN and GEM devices, and serum TCa concentrations were measured with a wet biochemistry method with blood from 125 lactating Holstein cows between calving to day 27 postpartum.
ResultsBland‐Altman plots showed a mean and total bias of 0.
05 and 0.
24 mmol/L for the EDAN device, respectively.
The intercept did not include zero, but the slope included 1.
0 in the Passing‐Bablok regression.
The sensitivity and specificity (Se/Sp) of the EDAN device were 93/94%, 93/90%, 91/93%, and 85/95% for iCa cut‐off values of <1.
00, 1.
05, 1.
10, and 1.
15 mmol/L, respectively, as determined with the GEM device.
The Se/Sp were 57/82% and 72/80% for EDAN and 57/80% and 72/79% for GEM at serum TCa cut‐off points <2.
15 and <2.
00 mmol/L, respectively.
The average iCa concentrations analyzed with the GEM and EDAN devices were 1.
04 ± 0.
18 and 1.
09 ± 0.
17, respectively.
ConclusionsThe EDAN device did not have satisfactory agreement with GEM and could not be used interchangeably, but it had satisfactory Se/Sp to diagnose subclinical hypocalcemia compared with the GEM‐derived iCa cut‐off points.
Serum TCa concentration cut‐off values were not suitable for diagnosing subclinical hypocalcemia because of unsatisfactory Se/Sp compared with iCa concentrations analyzed by the GEM and EDAN devices.
The iCa values analyzed using the EDAN and GEM devices were consistent with previously reported data.
Related Results
#1250 Measurement of ionized calcium with a point-of-care ionometer during treatment with etelcalcetide
#1250 Measurement of ionized calcium with a point-of-care ionometer during treatment with etelcalcetide
Abstract
Background and Aims
Etelcalcetide is an intravenous calcimimetic indicated for the treatment of mineral and bone disord...
Effect of flunixin meglumine treatment during and after embryo transfer on the pregnancy rate in cattle
Effect of flunixin meglumine treatment during and after embryo transfer on the pregnancy rate in cattle
ContentsThis study aimed to determine the effect of flunixin meglumine treatment during and after the transfer of in vivo produced embryos to Angus (cows) and Holstein (cows and he...
Production performance of Holstein crossbred cows under the existing farming system in a certain area of Bangladesh
Production performance of Holstein crossbred cows under the existing farming system in a certain area of Bangladesh
This study aimed to assess the effect of existing feeding system on milk yield and nutritional status and profitability of 75.0% and 87.5% Holstein crossbreed cows under existing f...
7987 Ravenous Bone
7987 Ravenous Bone
Abstract
Disclosure: Y. Oo: None. L. Srisawitri: None. P. Patel: None. M. Thein: None.
Introduction Hungry bone syndrome ( HBS ) is the rapid drop in ...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
The influence of paratypical factors on the character of the lactation curve of Simmental ? Holstein cows
The influence of paratypical factors on the character of the lactation curve of Simmental ? Holstein cows
The nature of the lactation curve and milk productivity have been studied in hybrid “Simmental ? red-and-white Holstein” cows with the genotype 1/4 of Simmental breed +3/4 red-an...
137 DIFFERENCES IN EMBRYO PRODUCTION BETWEEN LACTATING AND NON-LACTATING HOLSTEIN DONOR COWS
137 DIFFERENCES IN EMBRYO PRODUCTION BETWEEN LACTATING AND NON-LACTATING HOLSTEIN DONOR COWS
Embryo transfer is a common practice in reproductive management of large dairy herds. Data from 2 dairies in the San Joaquin Valley in California (5000 lactating Holstein producing...
British Food Journal Volume 45 Issue 9 1943
British Food Journal Volume 45 Issue 9 1943
I now pass on to an aspect of calcium metabolism which is more topical, but probably more controversial. I refer to the incidence of calcium deficiency. By what means can we determ...

