Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Performance evaluation of a low-cost odour trap installed in waterless urinals

View through CrossRef
Waterless urinals save precious fresh water normally used for flushing and reduce odour levels in restrooms. However, existing models of waterless urinals available on the market are expensive and maintenance costs of the odour traps of these urinals are also quite high. Experiments conducted using a low cost membrane-based waterless-urinal odour prevention trap available in India revealed a reduction of over 90.5% in ammonia gas concentration in the urinals. The ammonia levels observed, in the range of 0.22 to 0.30 ppm in waterless urinals fitted with the odour trap evaluated in this study, is comparable to values reported for the widely used sealant liquid based waterless urinals in the past. No sign of clogging was observed in the clogging tests conducted. Passage of particles up to 4 mm in size in the particle flow analysis tests conducted is somewhat higher than the 2 mm reported for sealant liquid and membrane odour traps in previous studies, and it reveals that the odour trap can perform in adverse conditions without getting clogged. Economics of installation and maintenance aspects of waterless urinals carried out here show that the odour trap evaluated in this study can really be a cost effective alternative.
Title: Performance evaluation of a low-cost odour trap installed in waterless urinals
Description:
Waterless urinals save precious fresh water normally used for flushing and reduce odour levels in restrooms.
However, existing models of waterless urinals available on the market are expensive and maintenance costs of the odour traps of these urinals are also quite high.
Experiments conducted using a low cost membrane-based waterless-urinal odour prevention trap available in India revealed a reduction of over 90.
5% in ammonia gas concentration in the urinals.
The ammonia levels observed, in the range of 0.
22 to 0.
30 ppm in waterless urinals fitted with the odour trap evaluated in this study, is comparable to values reported for the widely used sealant liquid based waterless urinals in the past.
No sign of clogging was observed in the clogging tests conducted.
Passage of particles up to 4 mm in size in the particle flow analysis tests conducted is somewhat higher than the 2 mm reported for sealant liquid and membrane odour traps in previous studies, and it reveals that the odour trap can perform in adverse conditions without getting clogged.
Economics of installation and maintenance aspects of waterless urinals carried out here show that the odour trap evaluated in this study can really be a cost effective alternative.

Related Results

Well and Layer Selection Method Study of CO2 Waterless Fracturing
Well and Layer Selection Method Study of CO2 Waterless Fracturing
Abstract CO2 waterless fracturing is a novel waterless fracturing technology. CO2 exists in the reservoir with supercritical state, and its fracturing stimulation me...
Adapting the novel-object recognition task to quantify how much attention rodents allocate to motivationally-salient objects
Adapting the novel-object recognition task to quantify how much attention rodents allocate to motivationally-salient objects
AbstractThe allocation of attention can be modulated by the emotional value of a stimulus. In order to understand the biasing influence of emotion on attention allocation further, ...
System development to select environmental odour nuisance panel members
System development to select environmental odour nuisance panel members
Environmental odour is one of the impacts that occur due to changes in air quality. Regulations related to measuring the level of odour with the panel method in Indonesia are still...
Development of a chimeric odour blend for attracting gravid malaria vectors
Development of a chimeric odour blend for attracting gravid malaria vectors
Abstract Background Odour-based tools targeting gravid malaria vectors may complement existing intervention strategies. Anopheles arabiensis are att...
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Otomatisasi Flame Trap Berbasis Sistem Pneumatik Pada Kendaraan Pengangkut BBM
Abstrak - Flame trap merupakan sebuah perangkat yang dipasang pada knalpot mobil tangki bahan bakar minyak (BBM) dengan bertujuan untuk mencegah terjadinya percikan api yang ditimb...
Evaluation of nano-confined catalytic oxidation air purification technology on eliminating marijuana chemicals and odour
Evaluation of nano-confined catalytic oxidation air purification technology on eliminating marijuana chemicals and odour
AbstractThe novel air purification technology, Nano-Confined Catalytic Oxidation (NCCO), has been proven to be effective at eliminating air pollutants. With the increasing legaliza...
Odour-Mediated Interactions Between an Apex Reptilian Predator and its Mammalian Prey
Odour-Mediated Interactions Between an Apex Reptilian Predator and its Mammalian Prey
Abstract An important but understudied modality for eavesdropping between predators and prey is olfaction, especially between non-mammalian vertebrate predators and their p...
INFLUENCE OF DIFFERENT ODOURS ON THE ASSOCIATIVE LEARNING OF LARVAL PARASITOID COTESIA PLUTELLAE (K.) (HYMENTOPTERA: BRACONIDAE)
INFLUENCE OF DIFFERENT ODOURS ON THE ASSOCIATIVE LEARNING OF LARVAL PARASITOID COTESIA PLUTELLAE (K.) (HYMENTOPTERA: BRACONIDAE)
The ability of insect parasitoids to learn a wide range of volatiles enables them to exploit the habitats while still maintaining their searching efficiency and achieving efficient...

Back to Top