Javascript must be enabled to continue!
Design of Dry and Long-Lasting Electrodes for ECG
View through CrossRef
Humans and animals both generate bioelectric signals through their tissues in static and active forms. These signals could be used to check the different physiological conditions of the body. Electrocardiogram (ECG) is one of the signals produced by the heart. ECG helps to monitor the health of the heart such as heart rate, contraction of heart muscles, and blood circulation. Abnormality in these parameters can cause serious cardiovascular diseases. Thus, monitoring of ECG helps to early diagnose cardiovascular diseases. To measure these signals electrodes or sensors are used. There are several types of electrodes are developed to measure heart bioelectric signals, but they are not very efficient, consume more power, and can harm the skin. The focus of this research was to design new and more efficient dry electrodes. For this purpose, ECG noise was simulated in MATLAB and the main schematic diagram was designed. Suitable components of the electrode were selected according to the desired output. The circuit was designed through Proteus software and printed on PCB sticker paper. The evaluation result revealed that our designed ECG dry electrodes were more efficient than traditional gel-based ECG electrodes. Newly designed electrodes displayed less noise impedance and did not harm the skin of the patients. These dry electrodes can be used in hospitals to monitor ECG.
The University of Lahore
Title: Design of Dry and Long-Lasting Electrodes for ECG
Description:
Humans and animals both generate bioelectric signals through their tissues in static and active forms.
These signals could be used to check the different physiological conditions of the body.
Electrocardiogram (ECG) is one of the signals produced by the heart.
ECG helps to monitor the health of the heart such as heart rate, contraction of heart muscles, and blood circulation.
Abnormality in these parameters can cause serious cardiovascular diseases.
Thus, monitoring of ECG helps to early diagnose cardiovascular diseases.
To measure these signals electrodes or sensors are used.
There are several types of electrodes are developed to measure heart bioelectric signals, but they are not very efficient, consume more power, and can harm the skin.
The focus of this research was to design new and more efficient dry electrodes.
For this purpose, ECG noise was simulated in MATLAB and the main schematic diagram was designed.
Suitable components of the electrode were selected according to the desired output.
The circuit was designed through Proteus software and printed on PCB sticker paper.
The evaluation result revealed that our designed ECG dry electrodes were more efficient than traditional gel-based ECG electrodes.
Newly designed electrodes displayed less noise impedance and did not harm the skin of the patients.
These dry electrodes can be used in hospitals to monitor ECG.
Related Results
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
Sistema de electrocardiografía ambulatoria para el análisis de la variabilidad de los intervalos de repolarización ventricular del ECG en la progresión de la enfermedad renal crónica en pacientes diabéticos e hipertensos
Sistema de electrocardiografía ambulatoria para el análisis de la variabilidad de los intervalos de repolarización ventricular del ECG en la progresión de la enfermedad renal crónica en pacientes diabéticos e hipertensos
(English) Chronic kidney disease is considered a risk factor for the development of cardiovascular disease because it is one of the main complications of diabetes mellitus and arte...
How Can We Identify the Best Implantation Site for an ECG Event Recorder?
How Can We Identify the Best Implantation Site for an ECG Event Recorder?
ZELLERHOFF, C., et al.: How Can We Identify the Best Implantation Site for an ECG Event Recorder? The aim of this study was to show how to find the preferable implantation site for...
Inter-beat and intra-beat ECG interval analysis based on state space and hidden markov models
Inter-beat and intra-beat ECG interval analysis based on state space and hidden markov models
Analyse des intervalles ECG inter- et intra-battement sur des modèles d'espace d'état et de Markov cachés
Les maladies cardiovasculaires sont l'une des principales ...
Development of AI-based method to detect the subtle ECG deviations from the population ECG norm
Development of AI-based method to detect the subtle ECG deviations from the population ECG norm
Abstract
Funding Acknowledgements
Type of funding sources: Public grant(s) – National budget only. Main funding source(s): Natio...
Prevalence of ECG abnormalities among adults with metabolic syndrome in a Nigerian Teaching Hospital
Prevalence of ECG abnormalities among adults with metabolic syndrome in a Nigerian Teaching Hospital
Background: Co-existence of metabolic syndrome (MetS) and electrocardiography (ECG) abnormalities heightens the risk of sudden cardiac death. However, there is a gap in evidence of...
Design and implementation of novel multiparametric nonclinical cardiovascular assessment devices using only four electrodes
Design and implementation of novel multiparametric nonclinical cardiovascular assessment devices using only four electrodes
(English) Cardiovascular diseases remain the leading cause of adverse outcomes and healthcare burden worldwide. The development of extra-hospital cardiovascular (CV) monitoring str...
Self-Supervised Electrocardiograph De-noising
Self-Supervised Electrocardiograph De-noising
Abstract
The electrocardiogram (ECG) records heart-beats and is potentially life-saving. However, the ECG signals (e.g., recorded by the standard ECG monitoring sys...