Ultrasound-guided reduction of intussusception in infants in a developing world: saline hydrostatic or pneumatic technique?

View through CrossRef
Abstract Purpose Non-operative reduction has emerged as first line in the management of uncomplicated intussusception. The aim of this study was to compare the outcome of saline hydrostatic reduction and pneumatic reduction of intussusception in infants. Methods This is a prospective study of infants with uncomplicated intussusception confirmed by ultrasound over a period of twenty-one months from December, 2018 to August, 2020. Fifty-two (69.3%) out of seventy-five infants underwent enema reduction under ultrasound guidance. The success rates, time to reduction and complication rates were assessed. Results The success rates, between the saline hydrostatic reduction group and pneumatic reduction group, were comparable [17(65.4%) versus 19(73.1%); relative risk (RR) 0.8; 95% confidence interval (CI) 0.6–1.2; p = 0.54]. The mean time to reduction was higher in the saline hydrostatic reduction group (15.4 ± 5.1 minutes versus 10.8 ± 4.1 minutes; p = 0.003). The two groups had similar complication rates; for perforation [1(3.8%) versus 0(0.0%); RR 0.9 (CI 0.9-1.0); p = 0.31] and recurrence [2(7.7%) versus 1(3.8%); RR 0.9 (CI 0.8-1.0); p = 0.55]. Conclusion Saline hydrostatic reduction and pneumatic reduction of uncomplicated intussusception under ultrasound guidance in infants might have comparable outcomes. However, pneumatic reduction may be faster.
Title: Ultrasound-guided reduction of intussusception in infants in a developing world: saline hydrostatic or pneumatic technique?
Description:
Abstract Purpose Non-operative reduction has emerged as first line in the management of uncomplicated intussusception.
The aim of this study was to compare the outcome of saline hydrostatic reduction and pneumatic reduction of intussusception in infants.
Methods This is a prospective study of infants with uncomplicated intussusception confirmed by ultrasound over a period of twenty-one months from December, 2018 to August, 2020.
Fifty-two (69.
3%) out of seventy-five infants underwent enema reduction under ultrasound guidance.
The success rates, time to reduction and complication rates were assessed.
Results The success rates, between the saline hydrostatic reduction group and pneumatic reduction group, were comparable [17(65.
4%) versus 19(73.
1%); relative risk (RR) 0.
8; 95% confidence interval (CI) 0.
6–1.
2; p = 0.
54].
The mean time to reduction was higher in the saline hydrostatic reduction group (15.
4 ± 5.
1 minutes versus 10.
8 ± 4.
1 minutes; p = 0.
003).
The two groups had similar complication rates; for perforation [1(3.
8%) versus 0(0.
0%); RR 0.
9 (CI 0.
9-1.
0); p = 0.
31] and recurrence [2(7.
7%) versus 1(3.
8%); RR 0.
9 (CI 0.
8-1.
0); p = 0.
55].
Conclusion Saline hydrostatic reduction and pneumatic reduction of uncomplicated intussusception under ultrasound guidance in infants might have comparable outcomes.
However, pneumatic reduction may be faster.

Related Results

Ultrasound-guided reduction of intussusception in infants in a developing world: saline hydrostatic or pneumatic technique?
Ultrasound-guided reduction of intussusception in infants in a developing world: saline hydrostatic or pneumatic technique?
Abstract Purpose: Non-operative reduction has emerged as first line in the management of uncomplicated intussusception. The aim of this study was to compare the outcome of ...
A 30-Year Experience in Treatment of Intestinal Intussusception in Children by Own Technique
A 30-Year Experience in Treatment of Intestinal Intussusception in Children by Own Technique
The issues on objectification and selection of indications for conservative treatment of intestinal intussusception in children remain to be disputable.Materials and methods. The e...
Risk factors for failure of hydrostatic reduction of intussusception in pediatric patients
Risk factors for failure of hydrostatic reduction of intussusception in pediatric patients
Abstract The aim of this current study was to explore the risk factors associated with failure of hydrostatic reduction of intussusception in pediatric patients. ...
Spontaneous Reduction of Intussusception in Infants: Is the Glass Half Empty or Half Full?
Spontaneous Reduction of Intussusception in Infants: Is the Glass Half Empty or Half Full?
Background: Intussusception is not an uncommon abdominal surgical emergency in children. However, spontaneous reduction of intussusception is possible, though uncommon. Materials a...
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
Ultrasound Guided Hydrostatic Versus Open Reduction in Intussusception
Ultrasound Guided Hydrostatic Versus Open Reduction in Intussusception
The surgical and nonsurgical technique has been utilized to manage intussusception. Surgical management of intussusceptions involves open laparotomy along with manual reduction. Th...

Back to Top