Javascript must be enabled to continue!
Bicuspid aortic valve flow dynamics using blood speckle tracking in children
View through CrossRef
Abstract
Funding Acknowledgements
Type of funding sources: Foundation. Main funding source(s): Labatt Family Heart Centre
Background
Bicuspid aortic valves (BAV) are the most common form of congenital heart disease with a prevalence of up to 2%. Fusion of the aortic cusps result in complex flow patterns in the aortic root which may contribute to the risk of progressive dilation. Imaging these patterns with conventional echocardiography is challenging due to the angle dependency of colour Doppler. Blood speckle tracking (BST) is a novel method based on high-frame rate ultrasound that is less angle-independent and developed to evaluate complex flow.
Purpose
The aims of this study were to 1) describe and quantify flow patterns in the aortic root using blood speckle tracking and 2) quantitatively compare flow parameters (energy loss, vorticity, kinetic energy) between paediatric patients with BAVs and those with normal aortic valves.
Methods
Clinical and routine echocardiographic parameters were collected for children with normal and BAVs. Children were imaged using a commercially available clinical scanner with research software enabling the acquisition of high-frame rate imaging and blood speckle tracking. Aortic root energy loss, vorticity and kinetic energy were measured in the parasternal long axis view.
Results
Data from 46 patients were analyzed (31 normal aortic valves, 15 BAVs) with no significant difference in age, height, weight or BSA between groups. Nine patients (60%) had right-left fusion; 6 (40%) had right-non fusion. Qualitative flow assessment in aortic root demonstrated disturbed flow in the BAV group (see figure) generally directed towards the non-fused cusp (i.e non coronary cusp in right-left fusion). Patients with a BAV had higher aortic valve peak velocity (2.1 m/s vs 0.9 m/s, p< 0.001); aortic root systolic energy loss (4.29 mW/m vs 1.79 mW/m, p< 0. 001), vorticity (38.7 1/s vs 31.1 1/s, p< 0.01) and kinetic energy (34.5 mJ/m vs 24.5 mJ/m, p = 0.04) compared to those with normal aortic valves.
Conclusion(s)
Blood speckle tracking can demonstrate altered flow patterns in the aortic root in patients with BAV. These patients have increased energy losses, vorticity and kinetic energy when compared to age matched patients with normal aortic valves however the relationship of theses parameters to aortic root dilation remains to be demonstrated.
Abstract Figure. Flow patterns (A-C) and analysis (D-F)
Oxford University Press (OUP)
Title: Bicuspid aortic valve flow dynamics using blood speckle tracking in children
Description:
Abstract
Funding Acknowledgements
Type of funding sources: Foundation.
Main funding source(s): Labatt Family Heart Centre
Background
Bicuspid aortic valves (BAV) are the most common form of congenital heart disease with a prevalence of up to 2%.
Fusion of the aortic cusps result in complex flow patterns in the aortic root which may contribute to the risk of progressive dilation.
Imaging these patterns with conventional echocardiography is challenging due to the angle dependency of colour Doppler.
Blood speckle tracking (BST) is a novel method based on high-frame rate ultrasound that is less angle-independent and developed to evaluate complex flow.
Purpose
The aims of this study were to 1) describe and quantify flow patterns in the aortic root using blood speckle tracking and 2) quantitatively compare flow parameters (energy loss, vorticity, kinetic energy) between paediatric patients with BAVs and those with normal aortic valves.
Methods
Clinical and routine echocardiographic parameters were collected for children with normal and BAVs.
Children were imaged using a commercially available clinical scanner with research software enabling the acquisition of high-frame rate imaging and blood speckle tracking.
Aortic root energy loss, vorticity and kinetic energy were measured in the parasternal long axis view.
Results
Data from 46 patients were analyzed (31 normal aortic valves, 15 BAVs) with no significant difference in age, height, weight or BSA between groups.
Nine patients (60%) had right-left fusion; 6 (40%) had right-non fusion.
Qualitative flow assessment in aortic root demonstrated disturbed flow in the BAV group (see figure) generally directed towards the non-fused cusp (i.
e non coronary cusp in right-left fusion).
Patients with a BAV had higher aortic valve peak velocity (2.
1 m/s vs 0.
9 m/s, p< 0.
001); aortic root systolic energy loss (4.
29 mW/m vs 1.
79 mW/m, p< 0.
001), vorticity (38.
7 1/s vs 31.
1 1/s, p< 0.
01) and kinetic energy (34.
5 mJ/m vs 24.
5 mJ/m, p = 0.
04) compared to those with normal aortic valves.
Conclusion(s)
Blood speckle tracking can demonstrate altered flow patterns in the aortic root in patients with BAV.
These patients have increased energy losses, vorticity and kinetic energy when compared to age matched patients with normal aortic valves however the relationship of theses parameters to aortic root dilation remains to be demonstrated.
Abstract Figure.
Flow patterns (A-C) and analysis (D-F).
Related Results
<b>Frequency of Bicuspid Aortic Valve and Coarctation of Aorta in Young Patients Presenting with Aortic Stenosis</b>
<b>Frequency of Bicuspid Aortic Valve and Coarctation of Aorta in Young Patients Presenting with Aortic Stenosis</b>
Background: Aortic stenosis in young patients is frequently associated with congenital structural abnormalities rather than degenerative valvular disease. Among these, bicuspid aor...
Later aorta operation after aortic valve replacement for bicuspid aortic valve
Later aorta operation after aortic valve replacement for bicuspid aortic valve
Abstract
Background
We investigated long-term outcomes, particularly later aorta operations and overall death in patients who underwent aortic valve...
Valve phenotype and likelihood of surgery in patients with bicuspid aortic valve
Valve phenotype and likelihood of surgery in patients with bicuspid aortic valve
Abstract
Background
It is well established, that patients with bicuspid aortic valve (BAV) are at increased risk of developing s...
Techniques of Aortic Valve Repair
Techniques of Aortic Valve Repair
Similar to mitral repair, newer methods of aortic valve reconstruction are achieving excellent outcomes with an 85% to 90% freedom from valve-related complications at 10 years. The...
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED] Guardian Blood Balance –Feel the difference Guardian Blood Balance makes! v1
[RETRACTED]Guardian Blood Balance Reviews (Works Or Hoax) Does Guardian Botanicals Blood Balance AU Really Works? Read Updated Report! Diabetes and Hypertension is such a health p...
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Incidence, Outcomes and Predictors of Aortic Regurgitation After Transcatheter Aortic Valve Replacement in Al Azhar University Hospitals and National Heart Institute, Egypt
Background: Aortic regurgitation (AR), which has ill-defined predictors and an unknown long-term influence on outcomes, is a significant transcatheter aortic valve replacement (TAV...
P1816Aortic root morphology in bicuspid aortic valve is related to the type of BAV
P1816Aortic root morphology in bicuspid aortic valve is related to the type of BAV
Abstract
Background
Dilatation of the ascending aorta associated with bicuspid aortic valve (BAV) is common and has been associa...
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Abstract
Introduction
Positron emission tomography-computed tomography (PET-CT) with 18F-sodium fluoride (18F-NaF) has been used...

