Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Experimental and Theoretical Study in Performance of Chilled Ceiling

View through CrossRef
The present study represents the experimental study for the performance of the chilled ceiling and it ability to achieve thermal condition in occupied zone. The experimental study included the effect of different internal load of (1600, 1300and 1000) W and different supplied chilled water temperatures of (13.3, 14.2, 16.8 and 18)°C on the performance of chilled ceiling. The experimental results show that the cooling capacity of chilled ceiling increases as temperature of supplied water decreases. For decreases in  temperature of  supplied chilled water by 33.5%,the cooling capacity of chilled ceiling  is increased  by 18.73%.This study presented theoretical study of velocity and temperature distribution   in occupied zone when using chilled ceiling.
Title: The Experimental and Theoretical Study in Performance of Chilled Ceiling
Description:
The present study represents the experimental study for the performance of the chilled ceiling and it ability to achieve thermal condition in occupied zone.
The experimental study included the effect of different internal load of (1600, 1300and 1000) W and different supplied chilled water temperatures of (13.
3, 14.
2, 16.
8 and 18)°C on the performance of chilled ceiling.
The experimental results show that the cooling capacity of chilled ceiling increases as temperature of supplied water decreases.
For decreases in  temperature of  supplied chilled water by 33.
5%,the cooling capacity of chilled ceiling  is increased  by 18.
73%.
This study presented theoretical study of velocity and temperature distribution   in occupied zone when using chilled ceiling.

Related Results

Standardizing insemination interval for turkey hens with diluted semen preserved at 5 °C for optimum fertility
Standardizing insemination interval for turkey hens with diluted semen preserved at 5 °C for optimum fertility
Standardizing insemination interval with liquid stored semen is necessary for better application of assisted reproductive biotechnology for genetic improvement in turkey. This expe...
Kinematics Analysis and Trajectory Planning of Segmentation Robot for Chilled Sheep Carcass
Kinematics Analysis and Trajectory Planning of Segmentation Robot for Chilled Sheep Carcass
HighlightsAn automatic sheep segmentation robot system was developed to realize the automatic segmentation of chilled sheep carcass and improve the segmentation efficiency.The mech...
Chilled Water System Analysis Tool (CWSAT) and Application to Manufacturing Plants
Chilled Water System Analysis Tool (CWSAT) and Application to Manufacturing Plants
<div class="section abstract"><div class="htmlview paragraph">Chilled water systems constitute a major portion of energy consumption in manufacturing plants. In many ca...
Development of the Chilled Water System Analysis Tool for Assessing Energy Conservation Opportunities
Development of the Chilled Water System Analysis Tool for Assessing Energy Conservation Opportunities
Chilled water systems constitute a major portion of energy consumption in air conditioning systems of the large buildings and process cooling of the manufacturing plants. These sys...
Improving Food Safety: Understanding Consumer Behaviour in Chilled or Frozen Food Purchases with “Design Thinking”
Improving Food Safety: Understanding Consumer Behaviour in Chilled or Frozen Food Purchases with “Design Thinking”
An innovation is introduced to improve the situation of storing and transporting chilled or frozen perishable items by applying design thinking approach based on the IDEO method of...
Morphological analysis of pork assessment
Morphological analysis of pork assessment
The article presents a morphological analysis of different thermal conditions of pork at the cellular level. The purpose of the study is to develop and improve classical histologic...
Changes in Cloud-Ceiling Heights and Frequencies over the United States since the Early 1950s
Changes in Cloud-Ceiling Heights and Frequencies over the United States since the Early 1950s
Abstract U.S. weather stations operated by NOAA’s National Weather Service (NWS) have undergone significant changes in reporting and measuring cloud ceilings. Statio...

Back to Top