Javascript must be enabled to continue!
The neutron veto of the XENONnT experiment: results with demineralized water
View through CrossRef
Abstract
Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs). To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC). The neutron veto (NV) can tag neutrons via their capture on gadolinium or hydrogen, which release
$$\gamma $$
γ
-rays that are subsequently detected as Cherenkov light. In this work, we present the first results of the XENONnT NV when operated with demineralized water only, before the insertion of gadolinium. Its efficiency for detecting neutrons is
$$({82\pm 1}){\%}$$
(
82
±
1
)
%
, the highest neutron detection efficiency achieved in a water Cherenkov detector. This enables a high efficiency of
$$({53\pm 3}){\%}$$
(
53
±
3
)
%
for the tagging of WIMP-like neutron signals, inside a tagging time window of
$${250}~{\upmu }\hbox {s}$$
250
μ
s
between TPC and NV, leading to a livetime loss of
$${1.6}{\%}$$
1.6
%
during the first science run of XENONnT.
Springer Science and Business Media LLC
E. Aprile
J. Aalbers
K. Abe
S. Ahmed Maouloud
L. Althueser
B. Andrieu
E. Angelino
D. Antón Martin
F. Arneodo
L. Baudis
M. Bazyk
L. Bellagamba
R. Biondi
A. Bismark
K. Boese
A. Brown
G. Bruno
R. Budnik
C. Cai
C. Capelli
J. M. R. Cardoso
A. P. Cimental Chávez
A. P. Colijn
J. Conrad
J. J. Cuenca-García
V. D’Andrea
L. C. Daniel Garcia
M. P. Decowski
A. Deisting
C. Di Donato
P. Di Gangi
S. Diglio
K. Eitel
S. el Morabit
A. Elykov
A. D. Ferella
C. Ferrari
H. Fischer
T. Flehmke
M. Flierman
W. Fulgione
C. Fuselli
P. Gaemers
R. Gaior
M. Galloway
F. Gao
S. Ghosh
R. Giacomobono
R. Glade-Beucke
L. Grandi
J. Grigat
H. Guan
M. Guida
P. Gyorgy
R. Hammann
A. Higuera
C. Hils
L. Hoetzsch
N. F. Hood
M. Iacovacci
Y. Itow
J. Jakob
F. Joerg
Y. Kaminaga
M. Kara
P. Kavrigin
S. Kazama
M. Kobayashi
D. Koke
A. Kopec
H. Landsman
R. F. Lang
L. Levinson
I. Li
S. Li
S. Liang
Y.-T. Lin
S. Lindemann
M. Lindner
K. Liu
M. Liu
J. Loizeau
F. Lombardi
J. Long
J.A.M. Lopes
T. Luce
Y. Ma
C. Macolino
J. Mahlstedt
A. Mancuso
L. Manenti
F. Marignetti
T. Marrodán Undagoitia
K. Martens
J. Masbou
E. Masson
S. Mastroianni
A. Melchiorre
J. Merz
M. Messina
A. Michael
K. Miuchi
A. Molinario
S. Moriyama
K. Morå
Y. Mosbacher
M. Murra
J. Müller
K. Ni
U. Oberlack
B. Paetsch
Y. Pan
Q. Pellegrini
R. Peres
C. Peters
J. Pienaar
M. Pierre
G. Plante
T. R. Pollmann
L. Principe
J. Qi
J. Qin
D. Ramírez García
M. Rajado
R. Singh
L. Sanchez
J. M. F. dos Santos
I. Sarnoff
G. Sartorelli
J. Schreiner
P. Schulte
H. Schulze Eißing
M. Schumann
L. Scotto Lavina
M. Selvi
F. Semeria
P. Shagin
S. Shi
J. Shi
M. Silva
H. Simgen
C. Szyszka
A. Takeda
Y. Takeuchi
P.-L. Tan
D. Thers
F. Toschi
G. Trinchero
C. D. Tunnell
F. Tönnies
K. Valerius
S. Vecchi
S. Vetter
F. I. Villazon Solar
G. Volta
C. Weinheimer
M. Weiss
D. Wenz
C. Wittweg
V. H. S. Wu
Y. Xing
D. Xu
Z. Xu
M. Yamashita
L. Yang
J. Ye
L. Yuan
G. Zavattini
M. Zhong
Title: The neutron veto of the XENONnT experiment: results with demineralized water
Description:
Abstract
Radiogenic neutrons emitted by detector materials are one of the most challenging backgrounds for the direct search of dark matter in the form of weakly interacting massive particles (WIMPs).
To mitigate this background, the XENONnT experiment is equipped with a novel gadolinium-doped water Cherenkov detector, which encloses the xenon dual-phase time projection chamber (TPC).
The neutron veto (NV) can tag neutrons via their capture on gadolinium or hydrogen, which release
$$\gamma $$
γ
-rays that are subsequently detected as Cherenkov light.
In this work, we present the first results of the XENONnT NV when operated with demineralized water only, before the insertion of gadolinium.
Its efficiency for detecting neutrons is
$$({82\pm 1}){\%}$$
(
82
±
1
)
%
, the highest neutron detection efficiency achieved in a water Cherenkov detector.
This enables a high efficiency of
$$({53\pm 3}){\%}$$
(
53
±
3
)
%
for the tagging of WIMP-like neutron signals, inside a tagging time window of
$${250}~{\upmu }\hbox {s}$$
250
μ
s
between TPC and NV, leading to a livetime loss of
$${1.
6}{\%}$$
1.
6
%
during the first science run of XENONnT.
Related Results
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
Potable Water Sources, Household Hygiene, and Sanitation Practices in Ikpoba Okha LGA, Edo State: Implications for Public Health and Sustainable Water Management
Omoregie, Andrew Edosa.1 Omoregie Abieyuwa Peace2 Okoro, Enyinnaya Okoro.3
1 College of Medi
BACKGROUND
Access to potable drinking water and sufficient sanitation continues to be an urgent global concern, particularly in developing regions where con...
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Comparative study of the effect of neutrons emitted from neutron source
241
Am-Be and curcumin on MCF-7 breast cancer cells in 3D culture medium
Abstract
Introduction
Cancer is one of the major medical problems threatening human health. Breast cancer ...
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
Study of coded source neutron imaging based on a compact accelerator
Study of coded source neutron imaging based on a compact accelerator
Compact accelerator based neutron source has lower cost and better flexibility than nuclear reactor. Neutron imaging using such a neutron source has attracted more and more attenti...
Determination of Coal Ash Content by Neutron-Neutron Logging
Determination of Coal Ash Content by Neutron-Neutron Logging
Abstract
The research is aimed at assessing the possibility of studying the ash content of coal seams using neutron-neutron logging in coal exploration wells drilled...
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
A New Method of Porosity Determination by D-T Neutron Generator and Dual CLYC Detector
Porosity is one of the essential parameters in conventional oil and gas reservoir evaluation, as well as plays an important role in the calculation of formation saturation and rese...
XENONnT analysis: Signal reconstruction, calibration, and event selection
XENONnT analysis: Signal reconstruction, calibration, and event selection
The XENONnT experiment, located at the INFN Laboratori Nazionali del Gran Sasso, Italy, features a 5.9 tonne liquid xenon time projection chamber surrounded by an instrumented neut...
The triggerless data acquisition system of the XENONnT experiment
The triggerless data acquisition system of the XENONnT experiment
Abstract
The XENONnT detector uses the latest and largest liquid xenon-based time projection chamber (TPC) operated by the XENON Collaboration, aimed at detecting We...

