Javascript must be enabled to continue!
Thermal Studies of New Lead(II) Coated‐Wire Membrane Electrodes
View through CrossRef
AbstractFive plastic membrane Pb2+‐selective electrodes were prepared based on 1,4‐bis(N‐tosyl‐o‐aminophenoxy)butane I, 1,4‐bis(N‐allyl‐N‐tosyl‐o‐aminophenoxy)butane II, 1,4‐bis(N‐benzyl‐N‐tosyl‐o‐aminophenoxy)butane III, 1,4‐bis[N‐(o‐allyloxybenzyl)‐N‐tosyl‐o‐aminophenoxy]butane IV, and 1,4‐bis(N‐octyl‐N‐tosyl‐o‐aminophenoxy)butane V as neutral carriers. The electrodes exhibited nearly Nernstian responses over the concentration ranges, 2.5×10−4–4.0×10−2, 2.5×10−5–4.0×10−2, 7.9×10−5–4.0×10−2, 2.2×10−5–4.0×10−2, and 1.9×10−4–4.0×10−2 M for electrodes composed with the ionophores I–V, respectively. All electrodes showed pH range of about 4.0 to 11.5 and working temperature range of 22 to 70 °C with isothermal temperature coefficients of 1.19×10−3, 1.16×10−3, 1.16×10−3, 1.00×10−3 , and 1.32×10−3 V/°C for electrodes I–V respectively.
Title: Thermal Studies of New Lead(II) Coated‐Wire Membrane Electrodes
Description:
AbstractFive plastic membrane Pb2+‐selective electrodes were prepared based on 1,4‐bis(N‐tosyl‐o‐aminophenoxy)butane I, 1,4‐bis(N‐allyl‐N‐tosyl‐o‐aminophenoxy)butane II, 1,4‐bis(N‐benzyl‐N‐tosyl‐o‐aminophenoxy)butane III, 1,4‐bis[N‐(o‐allyloxybenzyl)‐N‐tosyl‐o‐aminophenoxy]butane IV, and 1,4‐bis(N‐octyl‐N‐tosyl‐o‐aminophenoxy)butane V as neutral carriers.
The electrodes exhibited nearly Nernstian responses over the concentration ranges, 2.
5×10−4–4.
0×10−2, 2.
5×10−5–4.
0×10−2, 7.
9×10−5–4.
0×10−2, 2.
2×10−5–4.
0×10−2, and 1.
9×10−4–4.
0×10−2 M for electrodes composed with the ionophores I–V, respectively.
All electrodes showed pH range of about 4.
0 to 11.
5 and working temperature range of 22 to 70 °C with isothermal temperature coefficients of 1.
19×10−3, 1.
16×10−3, 1.
16×10−3, 1.
00×10−3 , and 1.
32×10−3 V/°C for electrodes I–V respectively.
Related Results
Procedure for Western blot v1
Procedure for Western blot v1
Goal: This document has the objective of standardizing the protocol for Western blot. This technique allows the detection of specific proteins separated on polyacrylamide gel and t...
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Structured 3D Printed Dry ECG Electrodes Using Copper Based Filament
Commercial wet Silver and Silver Chloride electrodes are used to monitor electrocardiogram (ECG) signals in numerous bioimpedance applications. These electrodes are frequently sing...
An Investigation into Hydrophobic Membrane Fouling in Desalination Using Membrane Distillation Technology
An Investigation into Hydrophobic Membrane Fouling in Desalination Using Membrane Distillation Technology
Demand for freshwater supplies is continuously increasing globally to the extent where some parts of the world became highly water stressed. In particular, the Arabian Gulf states ...
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Experimental investigations on coated copper wire and annealed copper wire electrodes in wire EDM machining through a comparative assessment employing the TOPSIS technique
Experimental investigations on coated copper wire and annealed copper wire electrodes in wire EDM machining through a comparative assessment employing the TOPSIS technique
Abstract
Metals that are electrically conductive but are difficult to work with are typically machined using WEDM (Wire Electric Discharge Machining). The production...
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
Numerical simulation of wire temperature field for prediction of wire transfer stability in laser hot wire welding
With preheating wire by resistance heat, laser hot wire welding improves process stability and wire deposition efficiency, which gives broad potential applications in surfacing and...
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
A Comparative Evaluation of Frictional Resistance of Conventional, Teflon and Epoxy Coated Stainless Steel Archwires in Metal, Ceramic Brackets – An In vitro Study
Aim and Objectives: To evaluate the frictional resistance of Conventional, Teflon, and Epoxy coated stainless steel archwires in Metal, Ceramic brackets.
Materials and Method...
Wireline Integrity Inspection Methods to Prevent Wire Breakage
Wireline Integrity Inspection Methods to Prevent Wire Breakage
Abstract
The structural integrity and predictable usability of slickline wire has perplexed wireline crews since wireline services were first developed. Miscalcul...

