Single-fed broadband CPW-fed circularly polarized implantable antenna for sensing medical applications

View through CrossRef
Biomedical telemetry relies heavily on implantable antennas. Due to this, we have designed and tested a compact, a circularly polarized, a low-profile biomedical implantable antenna that operate in the 2.45 GHz ISM band. In order to keep the antenna compact, modified co-planar waveguide (CPW) technology is used. Slotted rectangular patch with one 45-degree angle slot and truncated little patch on the left end of the ground plane generate a frequency-range antenna with circular polarization. Using a 0.25-millimeter-thick Roger Duroid-RT5880 substrate with a thickness of εr = 2.2, tanδ = 0.0009 provides flexibility. The volume of the antenna is 21 mm x 13.5 mm x 0.254 mm (0.25λg × 0.16λg × 0.003λg). The antenna covers 2.35–2.55 GHz (200 MHz) in free space and 1.63–1.17 GHz (1.17 GHz) in epidermal tissue. With skin tissue that has more bandwidth, the (x and y)-axis bends of the antenna are also simulated via the simulation. Bended antenna simulations and measurements show excellent agreement. At 2.45 GHz, the skin-like gel had -10dB impedance and 3dB axial ratio (AR) bandwidths of 47.7 and 53.8%, respectively. The ultimate result is that the SAR values are 0.78 W/kg in skin over 1 g of bulk tissue, as determined by simulations. The suggested SAR values are lower than the FCC’s maximum allowable limit (FCC). This antenna is small enough to be implanted in the body, making it perfect for biomedical applications.
Title: Single-fed broadband CPW-fed circularly polarized implantable antenna for sensing medical applications
Description:
Biomedical telemetry relies heavily on implantable antennas.
Due to this, we have designed and tested a compact, a circularly polarized, a low-profile biomedical implantable antenna that operate in the 2.
45 GHz ISM band.
In order to keep the antenna compact, modified co-planar waveguide (CPW) technology is used.
Slotted rectangular patch with one 45-degree angle slot and truncated little patch on the left end of the ground plane generate a frequency-range antenna with circular polarization.
Using a 0.
25-millimeter-thick Roger Duroid-RT5880 substrate with a thickness of εr = 2.
2, tanδ = 0.
0009 provides flexibility.
The volume of the antenna is 21 mm x 13.
5 mm x 0.
254 mm (0.
25λg × 0.
16λg × 0.
003λg).
The antenna covers 2.
35–2.
55 GHz (200 MHz) in free space and 1.
63–1.
17 GHz (1.
17 GHz) in epidermal tissue.
With skin tissue that has more bandwidth, the (x and y)-axis bends of the antenna are also simulated via the simulation.
Bended antenna simulations and measurements show excellent agreement.
At 2.
45 GHz, the skin-like gel had -10dB impedance and 3dB axial ratio (AR) bandwidths of 47.
7 and 53.
8%, respectively.
The ultimate result is that the SAR values are 0.
78 W/kg in skin over 1 g of bulk tissue, as determined by simulations.
The suggested SAR values are lower than the FCC’s maximum allowable limit (FCC).
This antenna is small enough to be implanted in the body, making it perfect for biomedical applications.

Related Results

Broadband
Broadband
Connecting I’ve moved house on the weekend, closer to the centre of an Australian capital city. I had recently signed up for broadband, with a major Australian Internet c...
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Magneto-Electric Antenna and Its Application in Geosteering Tool Design
Using coil antennae as transmitter and receiver to develop a geosteering tool, one has to increase the spacing between the transmitter and receiver to detect formation boundaries f...
A Flexible Broadband CPW-Fed Circularly Polarized Biomedical Implantable Antenna With Enhanced Axial Ratio Bandwidth
A Flexible Broadband CPW-Fed Circularly Polarized Biomedical Implantable Antenna With Enhanced Axial Ratio Bandwidth
Abstract Implantable antennas have a vital role in biomedical telemetry applications. Therefore, a compact low-profile circularly polarized biomedical implantable antenna o...
Utra-thin single-layered high-efficiency focusing metasurface lens
Utra-thin single-layered high-efficiency focusing metasurface lens
For potential applications of metasurfaces in lens technologies, we propose a cross circularly polarized focusing metasurface which is capable of transforming a circularly polarize...
Television and FM Broadcasting Antennas
Television and FM Broadcasting Antennas
Abstract Television broadcast services are located within four bands: the lower very‐high‐frequency (VHF) bands of 54–72 and 76–88 MHz, the upper VHF band of 174–216 MHz,...
RF communication between dual band implantable and on body antennas for biotelemetry application
RF communication between dual band implantable and on body antennas for biotelemetry application
Abstract This paper investigates two antennas for implantable communication, which are a wide-band, low-profile transmitting antenna with a circular polarization (CP) mer...

Back to Top