Perpendicular catheter orientation during papillary muscle ablation results in larger, deeper lesions

View through CrossRef
AbstractIntroductionAblation of papillary muscles (PMs) for refractory ventricular arrhythmias can often be challenging. The catheter approach and orientation during ablation may affect optimal radiofrequency (RF) delivery. Yet, no previous study investigated the association between catheter orientation and PM lesion size. We evaluated ablation lesion characteristics with various catheter orientations relative to the PM tissue during open irrigated ablation, using a standardized, experimental setting.MethodsViable bovine PM was positioned on a load cell in a circulating saline bath. RF ablation was performed over PM tissue at 50 W, with the open irrigated catheter positioned either perpendicular or parallel to the PM surface. Applied force was 10 g. Ablation lesions were sectioned and underwent quantitative morphometric analysis.ResultsA catheter position oriented directly perpendicular to the PM tissue resulted in the largest ablation lesion volumes and depths compared with ablation with the catheter parallel to PM tissue (75.26 ± 8.40 mm3 vs. 34.04 ± 2.91 mm3, p < .001) and (3.33 ± 0.18 mm vs. 2.24 ± 0.10 mm, p < .001), respectively. There were no significant differences in initial impedance, peak voltage, peak current, or overall decrease in impedance among groups. Parallel catheter orientation resulted in higher peak temperature (41.33 ± 0.28°C vs. 40.28 ± 0.24°C, p = .003), yet, there were no steam pops in either group.ConclusionFor PM ablation, catheter orientation perpendicular to the PM tissue achieves more effective and larger ablation lesions, with greater lesion depth. This may have implications for the chosen ventricular access approach, the type of catheter used, consideration for remote navigation, and steerable sheaths.
Title: Perpendicular catheter orientation during papillary muscle ablation results in larger, deeper lesions
Description:
AbstractIntroductionAblation of papillary muscles (PMs) for refractory ventricular arrhythmias can often be challenging.
The catheter approach and orientation during ablation may affect optimal radiofrequency (RF) delivery.
Yet, no previous study investigated the association between catheter orientation and PM lesion size.
We evaluated ablation lesion characteristics with various catheter orientations relative to the PM tissue during open irrigated ablation, using a standardized, experimental setting.
MethodsViable bovine PM was positioned on a load cell in a circulating saline bath.
RF ablation was performed over PM tissue at 50 W, with the open irrigated catheter positioned either perpendicular or parallel to the PM surface.
Applied force was 10 g.
Ablation lesions were sectioned and underwent quantitative morphometric analysis.
ResultsA catheter position oriented directly perpendicular to the PM tissue resulted in the largest ablation lesion volumes and depths compared with ablation with the catheter parallel to PM tissue (75.
26 ± 8.
40 mm3 vs.
34.
04 ± 2.
91 mm3, p < .
001) and (3.
33 ± 0.
18 mm vs.
2.
24 ± 0.
10 mm, p < .
001), respectively.
There were no significant differences in initial impedance, peak voltage, peak current, or overall decrease in impedance among groups.
Parallel catheter orientation resulted in higher peak temperature (41.
33 ± 0.
28°C vs.
40.
28 ± 0.
24°C, p = .
003), yet, there were no steam pops in either group.
ConclusionFor PM ablation, catheter orientation perpendicular to the PM tissue achieves more effective and larger ablation lesions, with greater lesion depth.
This may have implications for the chosen ventricular access approach, the type of catheter used, consideration for remote navigation, and steerable sheaths.

Related Results

Complex Collision Tumors: A Systematic Review
Complex Collision Tumors: A Systematic Review
Abstract Introduction: A collision tumor consists of two distinct neoplastic components located within the same organ, separated by stromal tissue, without histological intermixing...
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Poster 247: Muscle ERRγ Overexpression Mitigates the Muscle Atrophy after ACL injury
Objectives: Anterior cruciate ligament (ACL) reconstruction is the 6th most common orthopedic procedure performed in the United States (1,2). There is substanti...
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract Introduction  Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
Introduction: Novel ablation catheters equipped with mini-electrodes (ME) offer high resolution mapping for target tissue. This study aimed to evaluate the mappin...
Unusual Presentation of Mixed Lymphatic Malformation: A Case Report with Literature Review
Unusual Presentation of Mixed Lymphatic Malformation: A Case Report with Literature Review
Abstract Introduction There is a scarcity of reports on mixed lymphatic malformation. This case highlights a child with an extensive mixed lymphatic malformation, disfiguring multi...

Back to Top