CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
View through CrossRef
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes. The overall performance of such compressors can be improved by adding splitter vanes. The present work examines the effect of varying the geometrical location of the splitter vanes in the diffuser on the overall performance of a high-speed centrifugal compressor stage of a small gas turbine. To increase the pressure recovery through the diffuser, two radial sets of vanes are used. The first set of vanes (diffuser-1) is equipped with splitter vanes, placed mid-distance between the main vanes, while the vanes of the second set (diffuser-2) are conventional vanes. Flow through the compressor was simulated using the ANSYS 19 workbench program. Flow characteristics and compressor performance were obtained and analyzed for different circumferential positions of the splitting vanes relative to the main vanes of diffuser-1. The study covered seven positions of the splitter vanes including the original design of the diffuser where the splitter vanes were located at mid-distance between the main vanes. The analysis shows that, at design conditions, selecting the position of the splitter vanes to be nearer to the pressure side of the main vanes improves the stage performance. In the present study, locating the splitters at 33% of the angular distance between the main vanes leads to the best performance, and a significant improvement in the overall stage performance is recorded. The pressure recovery coefficient is raised by about 17%, the pressure ratio is increased by about 1.13%, and the stage efficiency is increased by about 2.01%, compared to the original splitter position. Performance improvement is related to the suppression of the flow separation and the more uniformity of flow. On the contrary, further moving the splitter closer to the main blade, the pressure recovery coefficient is decreased by about 2% than the position of 33% of the angular distance, but still higher than the original position by about 15% and a limited improvement in the compressor performance is noticed. Moving the splitter far out the main blade annihilates the static pressure recovery of the diffuser by about 2:7% compared with the original position. So, for the investigated compressor, the best position of the splitter blade in the circumferential direction, which provides the best stage performance in our parametric analysis, is not necessary to be at the mid-angular distance between the diffuser’s main blades, but it is achieved by moving the splitter to about 33% of the angular distance where the diminished loss from the suppressed flow separation is more prevailing and the instigated friction losses from splitter surfaces are less critical.
Springer Science and Business Media LLC
Title: CFD investigation of flow through a centrifugal compressor diffuser with splitter blades
Description:
AbstractThe aerodynamic losses in centrifugal compressors are mainly associated with the separated flow on the suction sides of impeller and diffuser vanes.
The overall performance of such compressors can be improved by adding splitter vanes.
The present work examines the effect of varying the geometrical location of the splitter vanes in the diffuser on the overall performance of a high-speed centrifugal compressor stage of a small gas turbine.
To increase the pressure recovery through the diffuser, two radial sets of vanes are used.
The first set of vanes (diffuser-1) is equipped with splitter vanes, placed mid-distance between the main vanes, while the vanes of the second set (diffuser-2) are conventional vanes.
Flow through the compressor was simulated using the ANSYS 19 workbench program.
Flow characteristics and compressor performance were obtained and analyzed for different circumferential positions of the splitting vanes relative to the main vanes of diffuser-1.
The study covered seven positions of the splitter vanes including the original design of the diffuser where the splitter vanes were located at mid-distance between the main vanes.
The analysis shows that, at design conditions, selecting the position of the splitter vanes to be nearer to the pressure side of the main vanes improves the stage performance.
In the present study, locating the splitters at 33% of the angular distance between the main vanes leads to the best performance, and a significant improvement in the overall stage performance is recorded.
The pressure recovery coefficient is raised by about 17%, the pressure ratio is increased by about 1.
13%, and the stage efficiency is increased by about 2.
01%, compared to the original splitter position.
Performance improvement is related to the suppression of the flow separation and the more uniformity of flow.
On the contrary, further moving the splitter closer to the main blade, the pressure recovery coefficient is decreased by about 2% than the position of 33% of the angular distance, but still higher than the original position by about 15% and a limited improvement in the compressor performance is noticed.
Moving the splitter far out the main blade annihilates the static pressure recovery of the diffuser by about 2:7% compared with the original position.
So, for the investigated compressor, the best position of the splitter blade in the circumferential direction, which provides the best stage performance in our parametric analysis, is not necessary to be at the mid-angular distance between the diffuser’s main blades, but it is achieved by moving the splitter to about 33% of the angular distance where the diminished loss from the suppressed flow separation is more prevailing and the instigated friction losses from splitter surfaces are less critical.
Related Results
Optimization of Centrifugal Compressor Splitter Blades Design Based on Regression Kriging Algorithm
Optimization of Centrifugal Compressor Splitter Blades Design Based on Regression Kriging Algorithm
Abstract
Centrifugal compressors are widely used in ships, automobiles, aerospace and other fields. At present, the centrifugal compressor is usually designed with splitter...
Centrifugal Compressor Design Considerations
Centrifugal Compressor Design Considerations
Initial design considerations of centrifugal compressor are commonly performed with experience base, although computer technology and numerical methods had made significantly progr...
The Application of PIV in the Study of Impeller-Diffuser Interaction in Centrifugal Fan: Part II — Impeller-Vaned Diffuser Interaction
The Application of PIV in the Study of Impeller-Diffuser Interaction in Centrifugal Fan: Part II — Impeller-Vaned Diffuser Interaction
Abstract
The real flow inside a turbomachinery passage is unsteady and strongly affected by wakes between stator and rotor. The aim of this study was to help our und...
Investigation on Clocking Effect of Diffuser in a Multi-Stage Centrifugal Pump
Investigation on Clocking Effect of Diffuser in a Multi-Stage Centrifugal Pump
Abstract
The clocking effect is an important phenomenon in the multi-stage Rotating machinery. In order to master the rules and mechanism of diffuser clocking effect on the...
Perancangan diffuser aromaterapi menggunakan metode quality function deployment
Perancangan diffuser aromaterapi menggunakan metode quality function deployment
Diffuser aromaterapi merupakan suatu alat yang bisa mengolah air dengan tetesan cairan aromaterapi. Diffuser aromaterapi dapat digunakan di berbagai tempat seperti ruang keluarga, ...
Unsteady Pre-Stall Behavior in a Centrifugal Compressor With Vaned Diffuser
Unsteady Pre-Stall Behavior in a Centrifugal Compressor With Vaned Diffuser
Abstract
Unsteady pre-stall behavior in a centrifugal compressor with a vaned diffuser was investigated by experimental and numerical analysis. The pre-stall disturb...
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Root Cause Analysis of the Catastrophic Failure of a Propylene Recycle Compressor
Abstract
A 2-section, 6-stage propylene recycle compressor experienced a catastrophic failure that resulted in extensive damage to its internals. The compressor was ...
Numerical studies on interactions between a centrifugal compressor and the back-propagated pressure waves originated from a pulse detonation combustor
Numerical studies on interactions between a centrifugal compressor and the back-propagated pressure waves originated from a pulse detonation combustor
In order to investigate the influence of the back-propagated pressure waves originated from a pulse detonation combustor on the operating characteristics of the compressor in the p...