Javascript must be enabled to continue!
An Ascending Aortic Haemodynamic Comparison Between Normotensive and Hypertensive Subjects
View through CrossRef
<p><strong>Background:</strong> Systemic hypertension, a common disorder with potentially serious complications, exerts ill effects through structural and functional modifications of arterial wall. Haemodynamics play an important role in the development of atherosclerosis. Local hemodynamic temporal pressure and wall shear stress are important for understanding the mechanisms leading to various complications in cardiovascular function.</p><p><strong>Objectives:</strong> Since we could not find such a study in literature involving Indian population, this prompted us to investigate and establish the relationship between the blood pressure and the ascending aortic pulse wave parameters in normal individuals and compare the same with hypertensives.</p><p><strong>Material and Methods:</strong> A case control study was done in a tertiary care hospital involving 25 hypertensive parents and further compared with 25 normotensive subjects of same age group acting as control. The GE ̶ P 100 Doppler echocardiography machine was used to study acceleration time, deceleration time, ejection time, ejection fraction, peak flow velocity and pressure gradient in hypertensives and compared the same with age matched normotensive. Also ascending aortic diameter was mapped at the annulus.</p><p><strong>Results:</strong> The results of our study confirmed our assumption that in hypertensive the ascending aortic haemodynamic parameters are abnormal and both systolic and diastolic blood pressure does exert a statistically significant influence on the Doppler parameters of ascending aorta. The acceleration time, deceleration time, pressure gradient and ejection time showed statistically significant increase in hypertensives when compared to normotensive. At the same time the ejection fraction and the ascending aortic diameter showed a statistically significant decrease than normotensive.</p><p><strong>Conclusion:</strong> We would conclude to say that the Doppler parameters of ascending aortic blood flow are abnormal in hypertensives. This altered haemodynamics may lead to further ill effects by way of altered peripheral haemodynamics. This Doppler evaluation of ascending aortic blood flow can be developed as a clinical tool for evaluating hypertensives and assessing the benefit of treatment of hypertension.</p>
Informatics Publishing Limited
Title: An Ascending Aortic Haemodynamic Comparison Between Normotensive and Hypertensive Subjects
Description:
<p><strong>Background:</strong> Systemic hypertension, a common disorder with potentially serious complications, exerts ill effects through structural and functional modifications of arterial wall.
Haemodynamics play an important role in the development of atherosclerosis.
Local hemodynamic temporal pressure and wall shear stress are important for understanding the mechanisms leading to various complications in cardiovascular function.
</p><p><strong>Objectives:</strong> Since we could not find such a study in literature involving Indian population, this prompted us to investigate and establish the relationship between the blood pressure and the ascending aortic pulse wave parameters in normal individuals and compare the same with hypertensives.
</p><p><strong>Material and Methods:</strong> A case control study was done in a tertiary care hospital involving 25 hypertensive parents and further compared with 25 normotensive subjects of same age group acting as control.
The GE ̶ P 100 Doppler echocardiography machine was used to study acceleration time, deceleration time, ejection time, ejection fraction, peak flow velocity and pressure gradient in hypertensives and compared the same with age matched normotensive.
Also ascending aortic diameter was mapped at the annulus.
</p><p><strong>Results:</strong> The results of our study confirmed our assumption that in hypertensive the ascending aortic haemodynamic parameters are abnormal and both systolic and diastolic blood pressure does exert a statistically significant influence on the Doppler parameters of ascending aorta.
The acceleration time, deceleration time, pressure gradient and ejection time showed statistically significant increase in hypertensives when compared to normotensive.
At the same time the ejection fraction and the ascending aortic diameter showed a statistically significant decrease than normotensive.
</p><p><strong>Conclusion:</strong> We would conclude to say that the Doppler parameters of ascending aortic blood flow are abnormal in hypertensives.
This altered haemodynamics may lead to further ill effects by way of altered peripheral haemodynamics.
This Doppler evaluation of ascending aortic blood flow can be developed as a clinical tool for evaluating hypertensives and assessing the benefit of treatment of hypertension.
</p>.
Related Results
P1820New parameters for the evaluation of mechanic and elastic properties of the aortic root in Marfan Syndrome
P1820New parameters for the evaluation of mechanic and elastic properties of the aortic root in Marfan Syndrome
Abstract
Background
Elastic properties of the thoracic aorta in patients with Marfan Syndrome (MS) have already been evaluated w...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract
Background
Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...
O024 Prognostic value of haemodynamic parameters in predicting adverse clinical events in type B aortic dissection
O024 Prognostic value of haemodynamic parameters in predicting adverse clinical events in type B aortic dissection
Abstract
Introduction
Ascertain the prognostic role of in-vivo 4D-flow magnetic resonance imaging (MRI) and computational fluid ...
Decreased expression of fibulin-4 in aortic wall of aortic dissection
Decreased expression of fibulin-4 in aortic wall of aortic dissection
In this research, we will examine the expression of Fibulin-4 in aortic wall to find out its role in aortic dissection development. The samples of aortic wall were obtained from 10...
Late Diagnosic of Bicuspid Aortic Valve with Severe Aortic Stenosis and Large Thoracic Aortic Aneurysm: Case Report and Review of the Literature.
Late Diagnosic of Bicuspid Aortic Valve with Severe Aortic Stenosis and Large Thoracic Aortic Aneurysm: Case Report and Review of the Literature.
Bicuspid aortic valve (BAV) is the most common congenital aortic valve anomaly and affects approximately 1%–2% of the population. Individuals with BAVs have higher risks of valvula...
SERUM NITRIC OXIDE METABOLITE (NOX) LEVELS IN HYPERTENSIVE PATIENTS AT REST: A COMPARISON OF AGE, GENDER, BLOOD PRESSURE AND COMPLICATIONS USING NORMOTENSIVE CONTROLS
SERUM NITRIC OXIDE METABOLITE (NOX) LEVELS IN HYPERTENSIVE PATIENTS AT REST: A COMPARISON OF AGE, GENDER, BLOOD PRESSURE AND COMPLICATIONS USING NORMOTENSIVE CONTROLS
SUMMARY
Hypertensive patients have pathophysiological changes such as atherosclerosis, endothelial dysfunction and inflammations. The patients’ serum nitric oxide metabolite (nitr...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...
Aortic Aneurysm
Aortic Aneurysm
Aortic diseases are relatively rare but are associated with high morbidity and mortality. Emergency physicians (EPs) should consider aortic disease in all patients with pain in the...

