Infection on the Sidelines: Evaluating Bacteremia Rates in Device-Dependent Cardiology Patients

View through CrossRef
Introduction: Patients with mechanical circulatory support (MCS) devices, such as ventricular assist devices (VAD) and extracorporeal membrane oxygenation (ECMO), are excluded from the National Healthcare Safety Network (NHSN) central line-associated bloodstream infection (CLABSI) criteria, whereas patients with intra-aortic balloon pumps (IABP) and Impella devices remain included. Since both MCS and Impella/IABP devices are associated with bloodstream infection risks, this study compares bacteremia rates among patients with VAD/ECMO, IABP/Impella, and central venous catheters (CVCs) to inform more accurate infection reporting. Methods: Using a surveillance database, we retrospectively reviewed bloodstream infections among patients with a CVC, ECMO/VAD, or IABP/Impella admitted to Duke University Hospital Cardiology units from January 2019 to July 2024. Bacteremia episodes were calculated per 1000 device days, with de-identified data pooled for final analysis. Results: A total of 849 bacteremia episodes were observed in patients with only a CVC (0.14 episodes/1000 device days), 98 in patients with ECMO/VAD (0.19/1000 device days), and 64 in patients with IABP/Impella (0.16/1000 device days). (Figure 1) Bacteremia incidence rate ratio (IRR) in patients with ECMO/VAD compared to patients with only a CVC was 1.30 (95% CI 1.05, 1.60, p-value 0.01). Bacteremia IRR in patients with Impella/IABP compared to patients with only a CVC was 1.12 (95% CI 0.87, 1.45, p-value 0.37). However, when we combined both ECMO/VAD and IABP/Impella bacteremia episodes and compared the bacteremia rate to patients with only a CVC, the incidence rate ratio was 1.22 (95% CI 1.03, 1.44, p-value 0.02). Discussion: The significantly different combined bacteremia rates among ECMO/VAD and IABP/Impella suggest that both device categories have significantly higher rates of bacteremia compared to CVC-only patients. Thus, NHSN should reconsider NHSN exclusion criteria for Impella/IABP patients similar to that for ECMO/VAD patients. Further collaboration with institutions, could strengthen findings and refine infection control protocols in high-risk, device-dependent patients.
Title: Infection on the Sidelines: Evaluating Bacteremia Rates in Device-Dependent Cardiology Patients
Description:
Introduction: Patients with mechanical circulatory support (MCS) devices, such as ventricular assist devices (VAD) and extracorporeal membrane oxygenation (ECMO), are excluded from the National Healthcare Safety Network (NHSN) central line-associated bloodstream infection (CLABSI) criteria, whereas patients with intra-aortic balloon pumps (IABP) and Impella devices remain included.
Since both MCS and Impella/IABP devices are associated with bloodstream infection risks, this study compares bacteremia rates among patients with VAD/ECMO, IABP/Impella, and central venous catheters (CVCs) to inform more accurate infection reporting.
Methods: Using a surveillance database, we retrospectively reviewed bloodstream infections among patients with a CVC, ECMO/VAD, or IABP/Impella admitted to Duke University Hospital Cardiology units from January 2019 to July 2024.
Bacteremia episodes were calculated per 1000 device days, with de-identified data pooled for final analysis.
Results: A total of 849 bacteremia episodes were observed in patients with only a CVC (0.
14 episodes/1000 device days), 98 in patients with ECMO/VAD (0.
19/1000 device days), and 64 in patients with IABP/Impella (0.
16/1000 device days).
(Figure 1) Bacteremia incidence rate ratio (IRR) in patients with ECMO/VAD compared to patients with only a CVC was 1.
30 (95% CI 1.
05, 1.
60, p-value 0.
01).
Bacteremia IRR in patients with Impella/IABP compared to patients with only a CVC was 1.
12 (95% CI 0.
87, 1.
45, p-value 0.
37).
However, when we combined both ECMO/VAD and IABP/Impella bacteremia episodes and compared the bacteremia rate to patients with only a CVC, the incidence rate ratio was 1.
22 (95% CI 1.
03, 1.
44, p-value 0.
02).
Discussion: The significantly different combined bacteremia rates among ECMO/VAD and IABP/Impella suggest that both device categories have significantly higher rates of bacteremia compared to CVC-only patients.
Thus, NHSN should reconsider NHSN exclusion criteria for Impella/IABP patients similar to that for ECMO/VAD patients.
Further collaboration with institutions, could strengthen findings and refine infection control protocols in high-risk, device-dependent patients.

Related Results

Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract Introduction Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
The Role of Some Hematological, Immunological, and Coagulation Parameters in Predicting Bacteremia
The Role of Some Hematological, Immunological, and Coagulation Parameters in Predicting Bacteremia
Background: The diagnosis of sepsis is based on clinical and laboratory parameters that indicate the presence of infection and organ dysfunction. The most specific test for the dia...

Back to Top