Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

42 COMPARISON OF COOLING RATES IN OOCYTE VITRIFICATION SYSTEMS USING A NUMERICAL SIMULATION

View through CrossRef
Interest in oocyte cryopreservation has increased due to the application of assisted reproductive technologies and the need for the establishment of ova/gene banks worldwide. In order to maintain cell viability, biological functions must be halted, inducing a suspended animation state by cooling it into a solid phase. Compared to cryopreservation of male gametes, oocytes represent a greater challenge due to their low surface area:volume. Vitrification, the solidification into an amorphous, glassy state while maintaining absence of intra- and extracellular ice crystals, requires high concentrations of cryoprotectants and extremely rapid cooling rates. Several vitrification devices such as open pulled straws (OPS), ultra fine pipette tips, nylon loops and polyethylene films have been introduced to manipulate minimal volumes and achieve high cooling rates. However, experimental comparison of cooling rates presents difficulties mainly because of the reduced size of these systems. To circumvent this limitation, a numerical simulation of cooling rates of various vitrification systems immersed in liquid nitrogen was conducted, solving the non-stationary heat transfer partial differential equation using the finite element method. Three external heat transfer coefficients (h = 200, 1000 and 2000 W m–2 K) were considered. The Cryotip® and OPS were approached as 2 concentric finite cylinders; differential equations representing heat transfer in cylindrical coordinates were described considering radial and axial coordinates and were numerically solved as a 1-dimensional heat conduction problem in an infinite cylinder. The Cryoloop® was approximated as a 1-dimensional heat flow system in Cartesian coordinates and Cryotop® was numerically described as an irregular bi-dimensional axial-symmetric problem. All differential equations were numerically solved using the finite element method in COMSOL Multiphysics 3.4. The domain was discretized in triangular (Cryotip®, OPS and Cryotop®) and linear elements (Cryoloop®) in order to obtain accurate numerical approximations. In each case, the warmest point of the system was identified to determine the time-temperature curve that allows the evaluation of the slowest cooling rate (worst condition). Results indicate the nylon loop (Cryoloop®) is the most efficient heat transfer system analysed, with a predicted cooling rate of 180 000°C min–1 for an external heat transfer coefficient h = 1000 W m–2 K when cooling from 20 to –130°C; in contrast, the pipette tips (Miniflex® showed the lowest performance with a cooling rate of 6164°C min–1 at same value of external heat transfer coefficient. Predicted cooling rates of OPS and Cryotop® (polyethylene film) were 40 909 and 37 500°C min–1, respectively for the same heat transfer coefficient. It can be concluded that in oocyte cryopreservation systems, in which experimental comparison of cooling rates presents difficulties due to the reduced size of the vitrification devices, the numerical simulations and the analysis of the predicted thermal histories could contribute to determine the performance of the different techniques.
Title: 42 COMPARISON OF COOLING RATES IN OOCYTE VITRIFICATION SYSTEMS USING A NUMERICAL SIMULATION
Description:
Interest in oocyte cryopreservation has increased due to the application of assisted reproductive technologies and the need for the establishment of ova/gene banks worldwide.
In order to maintain cell viability, biological functions must be halted, inducing a suspended animation state by cooling it into a solid phase.
Compared to cryopreservation of male gametes, oocytes represent a greater challenge due to their low surface area:volume.
Vitrification, the solidification into an amorphous, glassy state while maintaining absence of intra- and extracellular ice crystals, requires high concentrations of cryoprotectants and extremely rapid cooling rates.
Several vitrification devices such as open pulled straws (OPS), ultra fine pipette tips, nylon loops and polyethylene films have been introduced to manipulate minimal volumes and achieve high cooling rates.
However, experimental comparison of cooling rates presents difficulties mainly because of the reduced size of these systems.
To circumvent this limitation, a numerical simulation of cooling rates of various vitrification systems immersed in liquid nitrogen was conducted, solving the non-stationary heat transfer partial differential equation using the finite element method.
Three external heat transfer coefficients (h = 200, 1000 and 2000 W m–2 K) were considered.
The Cryotip® and OPS were approached as 2 concentric finite cylinders; differential equations representing heat transfer in cylindrical coordinates were described considering radial and axial coordinates and were numerically solved as a 1-dimensional heat conduction problem in an infinite cylinder.
The Cryoloop® was approximated as a 1-dimensional heat flow system in Cartesian coordinates and Cryotop® was numerically described as an irregular bi-dimensional axial-symmetric problem.
All differential equations were numerically solved using the finite element method in COMSOL Multiphysics 3.
4.
The domain was discretized in triangular (Cryotip®, OPS and Cryotop®) and linear elements (Cryoloop®) in order to obtain accurate numerical approximations.
In each case, the warmest point of the system was identified to determine the time-temperature curve that allows the evaluation of the slowest cooling rate (worst condition).
Results indicate the nylon loop (Cryoloop®) is the most efficient heat transfer system analysed, with a predicted cooling rate of 180 000°C min–1 for an external heat transfer coefficient h = 1000 W m–2 K when cooling from 20 to –130°C; in contrast, the pipette tips (Miniflex® showed the lowest performance with a cooling rate of 6164°C min–1 at same value of external heat transfer coefficient.
Predicted cooling rates of OPS and Cryotop® (polyethylene film) were 40 909 and 37 500°C min–1, respectively for the same heat transfer coefficient.
It can be concluded that in oocyte cryopreservation systems, in which experimental comparison of cooling rates presents difficulties due to the reduced size of the vitrification devices, the numerical simulations and the analysis of the predicted thermal histories could contribute to determine the performance of the different techniques.

Related Results

Health of 2-year-old children born after vitrified oocyte donation in comparison with peers born after fresh oocyte donation
Health of 2-year-old children born after vitrified oocyte donation in comparison with peers born after fresh oocyte donation
AbstractSTUDY QUESTIONDoes oocyte vitrification adversely affect the health of 2-year-old children compared with peers born after use of fresh oocytes in a donation programme?SUMMA...
O-059 ntermetabolites of cholesterol synthesis in granulosa cell and oocyte aging
O-059 ntermetabolites of cholesterol synthesis in granulosa cell and oocyte aging
Abstract With the development of society, there has been a significant delay in female fertility and an increasing desire for c...
Three-Dimensional Printing of Vitrification Loop Prototypes for Aquatic Species
Three-Dimensional Printing of Vitrification Loop Prototypes for Aquatic Species
Abstract Vitrification is a method of cryopreservation that freezes samples rapidly, while forming an amorphous solid (“glass”), typically in...
Porcine oocyte vitrification in optimized low toxicity solution with open pulled straws
Porcine oocyte vitrification in optimized low toxicity solution with open pulled straws
SummaryOne of the greatest challenges for reproductive cryobiologists today is to develop an efficient cryopreservation method for human and domestic animal oocytes. The objective ...
Effect of porcine immature oocyte vitrification on oocyte-cumulus cell gap junctional intercellular communication
Effect of porcine immature oocyte vitrification on oocyte-cumulus cell gap junctional intercellular communication
Abstract Vitrification may severely affect cumulus cells and oocyte morphology and viability, limiting their maturation and developmental potential. The aim of th...
Protective effects of the cumulus-corona radiata complex during vitrification of horse oocytes
Protective effects of the cumulus-corona radiata complex during vitrification of horse oocytes
Abstract Vitrifying oocytes is a potentially valuable means of preserving the female germ line, but significantly compromises oocyte developmental competence. Thi...

Back to Top