Test‐retest and time dependent variation and diagnostic values of vibratory sensation determined by biothesiometer and the Rydel‐Seiffer tuning fork

View through CrossRef
AbstractBackground and aimsPolyneuropathy is a common neurological disorder with many potential causes. An essential part in screening, diagnosis, and follow‐up evaluation of polyneuropathy is testing of the sensory function including vibratory sensation. The graduated Rydel‐Seiffer tuning fork and the biothesiometer have been developed to quantify vibratory sensation through detection thresholds. The aim of this study is to compare the vibration detection thresholds determined by the two instruments regarding intraindividual temporal changes, interindividual variation in healthy subjects and comparison of the diagnostic value in patients with a clinical suspicion of polyneuropathy.MethodsNinety‐four healthy subjects, 98 patients with and 97 patients without a diagnosis of polyneuropathy were included. Quantitative sensory testing including biothesiometry, structured clinical examination, and nerve conduction studies were performed three times during 52 weeks in healthy subjects and once in patients.ResultsThere were no significant changes over time for neither the Rydel‐Seiffer tuning fork nor the biothesiometer, and both had larger between‐subject variation than within‐subject variation. Relative intertrial variability was largest for the biothesiometer. Diagnostic value (sensitivity, specificity, positive predictive value, and negative predictive value) was moderate for both methods (Rydel‐Seiffer tuning fork: 58%, 74%, 70%, 64%; biothesiometer: 47%, 77%, 68%, 59%).InterpretationThe Rydel‐Seiffer tuning fork and the biothesiometer have a low test‐retest and time dependent variation. They perform almost equally as diagnostic tools in patients with suspected polyneuropathy with a tendency toward better performance of the tuning fork.
Title: Test‐retest and time dependent variation and diagnostic values of vibratory sensation determined by biothesiometer and the Rydel‐Seiffer tuning fork
Description:
AbstractBackground and aimsPolyneuropathy is a common neurological disorder with many potential causes.
An essential part in screening, diagnosis, and follow‐up evaluation of polyneuropathy is testing of the sensory function including vibratory sensation.
The graduated Rydel‐Seiffer tuning fork and the biothesiometer have been developed to quantify vibratory sensation through detection thresholds.
The aim of this study is to compare the vibration detection thresholds determined by the two instruments regarding intraindividual temporal changes, interindividual variation in healthy subjects and comparison of the diagnostic value in patients with a clinical suspicion of polyneuropathy.
MethodsNinety‐four healthy subjects, 98 patients with and 97 patients without a diagnosis of polyneuropathy were included.
Quantitative sensory testing including biothesiometry, structured clinical examination, and nerve conduction studies were performed three times during 52 weeks in healthy subjects and once in patients.
ResultsThere were no significant changes over time for neither the Rydel‐Seiffer tuning fork nor the biothesiometer, and both had larger between‐subject variation than within‐subject variation.
Relative intertrial variability was largest for the biothesiometer.
Diagnostic value (sensitivity, specificity, positive predictive value, and negative predictive value) was moderate for both methods (Rydel‐Seiffer tuning fork: 58%, 74%, 70%, 64%; biothesiometer: 47%, 77%, 68%, 59%).
InterpretationThe Rydel‐Seiffer tuning fork and the biothesiometer have a low test‐retest and time dependent variation.
They perform almost equally as diagnostic tools in patients with suspected polyneuropathy with a tendency toward better performance of the tuning fork.

Related Results

Subsea Installations Using Vibratory Piling Hammers
Subsea Installations Using Vibratory Piling Hammers
ABSTRACT During the summer of 1987 ICE hydraulic vibratory hammers were used 3 times successfully for subsea installations of anchorpiles and template foundation ...
Finite-Element Analysis of Trident-Type Tuning Fork Resonator for Vibratory Gyroscope
Finite-Element Analysis of Trident-Type Tuning Fork Resonator for Vibratory Gyroscope
We have investigated the possibility of producing a highly stable piezoelectric vibratory gyroscope. In order to achieve such a gyroscope, a trident-type tuning fork resonator was ...
Shift Force Loading Rules Research for Automated Mechanical Transmission
Shift Force Loading Rules Research for Automated Mechanical Transmission
To improve the system reliability and reduce the shift shock of Automated Mechanical Transmission, shift force loading rules is researched on the basis of strength and stiffness an...
Experimental study on the influence of high-frequency vibratory mixing on concrete performance
Experimental study on the influence of high-frequency vibratory mixing on concrete performance
Abstract The method and parameter of mixing are crucial to the quality of concrete, and ordinary vibratory mixing is beneficial to the performance of concrete, which...
ATM promotes reversed fork processing during DNA interstrand cross-link repair
ATM promotes reversed fork processing during DNA interstrand cross-link repair
Abstract During replication-coupled DNA interstrand cross-link (ICL) repair, fork reversal is thought to enable the Fanconi anemia (FA) pathway to resolve the ICL throu...
Hydraulic Vibration Hammer without Resonance Technology Status Study
Hydraulic Vibration Hammer without Resonance Technology Status Study
Hydraulic vibratory hammer using the working principle of vibratory pile sinking is an important equipment in pile foundation construction, which can be used for sinking and extrac...
Experimental Considerations on the Piezoelectric Vibratory Gyrosensor Using a Trident Tuning-Fork Resonator
Experimental Considerations on the Piezoelectric Vibratory Gyrosensor Using a Trident Tuning-Fork Resonator
This paper concerns the piezoelectric vibratory gyrosensor using a trident tuning-fork resonator characterized by high stability. In the first part of this paper, the methods of a...

Back to Top