Feasibility of measuring fusional vergence amplitudes objectively
View through CrossRef
Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests. Forty-nine adults participated in the study. Participants’ negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research). Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively. Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements. Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar. A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes. The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.74 ± 3.35 PD and -1.97 ± 2.60 PD, respectively, which were comparable to those obtained for the subjective tests. For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.31 ± 6.44 PD and -2.84 ± 7.01 PD, respectively). This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests. However, these tests cannot be used interchangeably due to their poor agreement.
Public Library of Science (PLoS)
Title: Feasibility of measuring fusional vergence amplitudes objectively
Description:
Two tests to measure fusional vergence amplitudes objectively were developed and validated against the two conventional clinical tests.
Forty-nine adults participated in the study.
Participants’ negative (BI, base in) and positive (BO, base out) fusional vergence amplitudes at near were measured objectively in an haploscopic set-up by recording eye movements with an EyeLink 1000 Plus (SR Research).
Stimulus disparity changed in steps or smoothly mimicking a prim bar and a Risley prism, respectively.
Break and recovery points were determined offline using a custom Matlab algorithm for the analysis of eye movements.
Fusional vergence amplitudes were also measured with two clinical tests using a Risley prism and a prism bar.
A better agreement between tests was found for the measurement of BI than for BO fusional vergence amplitudes.
The means ± SD of the differences between the BI break and recovery points measured with the two objective tests were -1.
74 ± 3.
35 PD and -1.
97 ± 2.
60 PD, respectively, which were comparable to those obtained for the subjective tests.
For the BO break and recovery points, although the means of the differences between the two objective tests were small, high variability between subjects was found (0.
31 ± 6.
44 PD and -2.
84 ± 7.
01 PD, respectively).
This study showed the feasibility to measure fusional vergence amplitudes objectively and overcome limitations of the conventional subjective tests.
However, these tests cannot be used interchangeably due to their poor agreement.
Related Results
Comparison of Measured Fusional Vergence Amplitudes using Prism Bar and Synoptophore in Sudanese Patients with Near Exophoria
Comparison of Measured Fusional Vergence Amplitudes using Prism Bar and Synoptophore in Sudanese Patients with Near Exophoria
Background:
Assessment of the fusional vergence amplitudes constitutes one of the most important diagnostic tools to obtain information about the ability to mai...
Comparison of accommodation and vergence parameters in early and late-onset myopic adults
Comparison of accommodation and vergence parameters in early and late-onset myopic adults
Abstract
Significance
Myopia is a growing public health concern, and understanding the visual function differences among ...
Heterophoria, fusional vergence, and near point of convergence in Sudanese hospital-based population
Heterophoria, fusional vergence, and near point of convergence in Sudanese hospital-based population
Background: Fusional vergence amplitude is the amount of convergence and divergence that can be induced before fusion is lost and fusional vergence amplitude controls heterophoria....
Tonic Vergence and Vergence Adaptation
Tonic Vergence and Vergence Adaptation
ABSTRACT:
In the absence of an adequate visual stimulus, the eyes are typically converged by approximately 0.25 to 0.75 meter angles (MA). This vergence response ...
Vergence Eye Movements
Vergence Eye Movements
This chapter reviews the stimuli for vergence, the properties of
fusional and accommodative vergence, as well as vergence made in
combination with saccades or vestibula...
Jalur Saraf Vergence : Systematic Literature Review
Jalur Saraf Vergence : Systematic Literature Review
Vergence movement is an important mechanism in eye coordination to maintain visual focus. The neural pathways controlling vergence involve complex interactions between various brai...
The Vergence System
The Vergence System
Vergence eye movements shift the gaze point between near and far, such that the image of a target is maintained simultaneously on both foveae. Unlike other eye movement systems, ve...
Large-scale cortico-cerebellar computations for horizontal and vertical vergence in humans
Large-scale cortico-cerebellar computations for horizontal and vertical vergence in humans
AbstractHorizontal and vertical vergence eye movements play a central role in binocular coordination. Neurophysiological studies suggest that cortical and subcortical regions in an...