Javascript must be enabled to continue!
Effect of Early and Late Presence of Sulfate Ions on Steel Corrosion Development in Alkaline Solution
View through CrossRef
Abstract
In post-tensioned (PT) concrete, grout is used to protect the steel strand by providing a physical barrier to external moisture and contaminants and allowing for a protective passive film. However, corrosion failures of tendons associated with deficient grout materials occurred in Florida. Recent works demonstrated that elevated sulfate levels in alkaline environments can promote steel corrosion. However, testing in concrete materials sometimes did not reveal the role of sulfates. The purpose of the work here was to identify the influence of early and late sulfate ions presence on the formation of the passive film in alkaline solution. Steel specimens were exposed to saturated calcium hydroxide solution with sulfate levels ranging from 10,000 to 100,000 ppm. Electrochemical tests including open-circuit potential (OCP), linear polarization resistance (LPR), and anodic potentiodynamic polarization scans were made to identify conditions for steel passivation and corrosion initiation. In tests with early addition of sulfate, results indicated higher corrosion activity with greater sulfate concentration. Late sulfate additions after steel prepassivation showed less significant corrosion development below 30,000 ppm and relatively less corrosion in comparison to the early sulfate addition case. It was apparent that the sulfate ion concentrations in deficient grout can impair steel passivity but later sulfate presence due to external contamination would have less aggravating effect on corrosion development.
Title: Effect of Early and Late Presence of Sulfate Ions on Steel Corrosion Development in Alkaline Solution
Description:
Abstract
In post-tensioned (PT) concrete, grout is used to protect the steel strand by providing a physical barrier to external moisture and contaminants and allowing for a protective passive film.
However, corrosion failures of tendons associated with deficient grout materials occurred in Florida.
Recent works demonstrated that elevated sulfate levels in alkaline environments can promote steel corrosion.
However, testing in concrete materials sometimes did not reveal the role of sulfates.
The purpose of the work here was to identify the influence of early and late sulfate ions presence on the formation of the passive film in alkaline solution.
Steel specimens were exposed to saturated calcium hydroxide solution with sulfate levels ranging from 10,000 to 100,000 ppm.
Electrochemical tests including open-circuit potential (OCP), linear polarization resistance (LPR), and anodic potentiodynamic polarization scans were made to identify conditions for steel passivation and corrosion initiation.
In tests with early addition of sulfate, results indicated higher corrosion activity with greater sulfate concentration.
Late sulfate additions after steel prepassivation showed less significant corrosion development below 30,000 ppm and relatively less corrosion in comparison to the early sulfate addition case.
It was apparent that the sulfate ion concentrations in deficient grout can impair steel passivity but later sulfate presence due to external contamination would have less aggravating effect on corrosion development.
Related Results
Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Investigating the Effect of High Pressures and Temperatures on Corrosion Inhibition for Water-Based Muds
Corrosion is defined as gradual degradation of metal caused by a chemical or electrochemical reaction with its environment. In oil and gas sector, components can corrode at any sta...
Laser surface treatment to inhibit observed corrosion of reinforcing steel in sulphate: alkaline media
Laser surface treatment to inhibit observed corrosion of reinforcing steel in sulphate: alkaline media
PurposeThe effect of chlorides on corrosion of reinforcing steel is well documented in the literature. However, few studies have focused attention on the effect of sulphates on the...
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 1: Electrochemical Behavior of Steel in Alkaline Sulfate Solutions
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 1: Electrochemical Behavior of Steel in Alkaline Sulfate Solutions
Severe corrosion recently documented in Florida post-tensioned bridges were related to grout segregation that created deficient grout with characteristics of having low chloride co...
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Abstract
CO2 corrosion product scales formed on 13Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the pap...
Anodic Behavior of Steel in Enhanced Sulfate Solutions
Anodic Behavior of Steel in Enhanced Sulfate Solutions
Abstract
Severe corrosion of post-tensioned tendons in Florida bridges utilizing pre-packaged thixotropic grout products were documented. In those cases, conventiona...
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 3: Segregated Grout with Elevated Sulfate and Vestigial Chloride Content
Corrosion of Post-Tensioned Tendons with Deficient Grout, Part 3: Segregated Grout with Elevated Sulfate and Vestigial Chloride Content
Severe corrosion of post-tensioned (PT) tendons with pre-packaged thixotropic grout was documented in Florida bridges after less than 8 years of service. In those bridges, corrosio...
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Characterization of Biofilm Formation and Coating Degradation By Electrochemical Impedance Spectroscopy
Recent findings showed severe localized corrosion of submerged steel bridge piles in a Florida bridge and was associated with microbial activity in presence of marine foulers (Perm...
Destruction of toluene and xylene by sulfatе-reducing bacteria
Destruction of toluene and xylene by sulfatе-reducing bacteria
As a result of human activity aromatic hydrocarbons enter the environment in large quantities, contaminating it. Dropping of insufficiently treated wastewater drains considerably d...