The accuracy of Intramedullary Femoral alignment in Total Knee Replacement in the prescence of ipsilateral Hip Replacement

View through CrossRef
Objectives: During total knee replacement (TKR) surgery, the most commonly used method for aligning the distal femur appropriately is via an intramedullary (IM) distal femoral alignment rod. The alignment of the rod itself is reliant on the isthmus which is used to most accurately place the rod in the correct anatomical axis. In the instance of something preventing the rod from entering the isthmus correctly, such as a hip replacement, then the degree of accuracy could be assumed to be even less. Mechanical-anatomical malalignment has been shown to decrease the implant (TKR) survivalĀ and so methods of increasing accuracy of alignment relative to the mechanical axis have been developed. At present the most accurate method intraoperatively is computer navigation and several studies have demonstrated improved alignment. An increasing number of patients year on year are having both knee and hip replacements and as the population ages the likelihood of having both a knee and hip replacement will also increase. We propose that the presence of a hip replacement within the isthmus of the femur may further decrease the accuracy of the IM alignment of the femur leading to incorrect implant positioning. Methods: The study was conducted on 10 cadaveric specimens (20 femurs). Computational navigation instrumentation was attached in turn to each femur and the ideal alignment data recorded in a standard fashion by a single operator (principal investigator). A standard entry port was then be made in the femur for the introduction of the IM rod. An IM rod was then inserted with the distal femoral cutting block in the accepted position recorded blindly on the computer navigation (both in terms of varus/valgus alignment to the mechanical axis and the degree of flexion). The process was then repeated at 3 levels to represent primary and revision hip lengths from the greater trochanter (replicating the changes that would occur in the presence of a hip replacement) The process was recorded three times at each level. Results: The resection angles between the cutting surface and the mechanical axis were measured and collected by means of computer navigation system. The results show that the IM alignment had mean Valgus of 0 degrees +/- 0.8 but with a hip replacement in situ this increased to 0.46 degrees +/- 1.49 (range 2.5 varus to 4.5 valgus), with a revision stem 0.825 +/- 1.68 (range 2.5 varus to 4.5 valgus) and long stemmed revision 1.325 +/- 2.09 (range 5 varus to 6.5 valgus). In terms of Flexion IM alignment had a mean flexion of 0.92 +/- 1.7 (range 3 extension to 4 flexion) but with a hip replacement in situ this increased to 1.88 degrees +/- 2.03 (range 2.5 extension to 8.5 flexion), with a revision stem 2.35 +/- 2.2 (range 2.5 extension to 8 flexion) and long stemmed revision 2.75 +/- 2.16 (range 3.5 extension to 7 flexion). Conclusion: This Study concludes that the prescence of a hip replacement, in particular long stemmed prosthesis, further reduces the accuracy of IM alignment in the Femur for Total Knee Replacement. Consideration of an alternative method, such as navigation, should be considered in such situations.
Title: The accuracy of Intramedullary Femoral alignment in Total Knee Replacement in the prescence of ipsilateral Hip Replacement
Description:
Objectives: During total knee replacement (TKR) surgery, the most commonly used method for aligning the distal femur appropriately is via an intramedullary (IM) distal femoral alignment rod.
The alignment of the rod itself is reliant on the isthmus which is used to most accurately place the rod in the correct anatomical axis.
In the instance of something preventing the rod from entering the isthmus correctly, such as a hip replacement, then the degree of accuracy could be assumed to be even less.
Mechanical-anatomical malalignment has been shown to decrease the implant (TKR) survivalĀ and so methods of increasing accuracy of alignment relative to the mechanical axis have been developed.
At present the most accurate method intraoperatively is computer navigation and several studies have demonstrated improved alignment.
An increasing number of patients year on year are having both knee and hip replacements and as the population ages the likelihood of having both a knee and hip replacement will also increase.
We propose that the presence of a hip replacement within the isthmus of the femur may further decrease the accuracy of the IM alignment of the femur leading to incorrect implant positioning.
Methods: The study was conducted on 10 cadaveric specimens (20 femurs).
Computational navigation instrumentation was attached in turn to each femur and the ideal alignment data recorded in a standard fashion by a single operator (principal investigator).
A standard entry port was then be made in the femur for the introduction of the IM rod.
An IM rod was then inserted with the distal femoral cutting block in the accepted position recorded blindly on the computer navigation (both in terms of varus/valgus alignment to the mechanical axis and the degree of flexion).
The process was then repeated at 3 levels to represent primary and revision hip lengths from the greater trochanter (replicating the changes that would occur in the presence of a hip replacement) The process was recorded three times at each level.
Results: The resection angles between the cutting surface and the mechanical axis were measured and collected by means of computer navigation system.
The results show that the IM alignment had mean Valgus of 0 degrees +/- 0.
8 but with a hip replacement in situ this increased to 0.
46 degrees +/- 1.
49 (range 2.
5 varus to 4.
5 valgus), with a revision stem 0.
825 +/- 1.
68 (range 2.
5 varus to 4.
5 valgus) and long stemmed revision 1.
325 +/- 2.
09 (range 5 varus to 6.
5 valgus).
In terms of Flexion IM alignment had a mean flexion of 0.
92 +/- 1.
7 (range 3 extension to 4 flexion) but with a hip replacement in situ this increased to 1.
88 degrees +/- 2.
03 (range 2.
5 extension to 8.
5 flexion), with a revision stem 2.
35 +/- 2.
2 (range 2.
5 extension to 8 flexion) and long stemmed revision 2.
75 +/- 2.
16 (range 3.
5 extension to 7 flexion).
Conclusion: This Study concludes that the prescence of a hip replacement, in particular long stemmed prosthesis, further reduces the accuracy of IM alignment in the Femur for Total Knee Replacement.
Consideration of an alternative method, such as navigation, should be considered in such situations.

Related Results

Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Physiological and biomechanical factors contributing to the hip adduction angle in female runners
Running is a popular form of exercise that is accompanied by many health benefits. However, running also comes with a risk of overuse injuries. Women have a higher risk for overuse...
Coexisting Granulomatous Mastitis and Breast Cancer: A Systematic Review
Coexisting Granulomatous Mastitis and Breast Cancer: A Systematic Review
Abstract Introduction: Granulomatous mastitis (GM) is a rare inflammatory breast disease that mimics carcinoma. GM can coexist with breast cancer (BC), though the relationship rema...
Self-Made Distal Femoral Extramedullary Positioning Osteotomy Template In Total Knee Arthroplasty
Self-Made Distal Femoral Extramedullary Positioning Osteotomy Template In Total Knee Arthroplasty
Abstract Introduction: The objective of this study was to assess the success of total knee arthroplasty with the use of extramedullary positioning osteotomy templates for l...
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
DXA-derived hip shape is associated with hip fracture: a longitudinal study of 38,123 UK Biobank participants
Abstract Despite advancements in fracture prediction tools and osteoporosis management, hip fractures remain a significant consequence of bone fr...
Radiographic Analysis of Lower Limb Alignment in Patients with Knee Osteoarthritis
Radiographic Analysis of Lower Limb Alignment in Patients with Knee Osteoarthritis
Background and Objectives: Knee osteoarthritis (OA) is a prevalent musculoskeletal disorder. This study aims to assess the hip-knee-ankle anatomical alignment in patients with OA a...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Background The introduction of sex-specific (SS) knee prosthesis designs was an approach to offer more sizing options and is based on the anatomic sex differences. Thes...
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
Association of Hip Radiograph Findings With Pain and Function in Patients Presenting With Low Back Pain
AbstractBackgroundRelationships between low back pain (LBP) and the hip in patient cohorts have been described primarily in patients with moderate to severe hip osteoarthritis (OA)...

Back to Top