Javascript must be enabled to continue!
Real Time Retinal Optic Disc Segmentation via Guided filter and Discrete Wavelet Transform
View through CrossRef
Abstract
In the world, glaucoma is the one of the main causes for loosing vision. Optical Coherence Tomography or fundus camera is utilized to capture the optic disc and optic cup images. For the detection of glaucoma and afterwards monitoring the patients, investigation of the head of optic nerve or cup-to-disc ratio (CDR) is an important factor. For computing the CDR value, segmentation of optic disc and optic cup are utilized for the isolation of the relevant parts of the fundus image. Even though ophthalmologists are computing the CDR value physically, however, it limits the identification of glaucoma at the early stage. The accurate value of CDR is hard to find out if the optic cup and optic disc are not well defined properly. Thus, this paper has suggested a combined model of Guided filter and Discrete Wave Transform (DWT) for the enhancement and OD segmentation. Hysteresis thresholding is utilized for the optic cup segmentation. A set of 50 images of 25 patients are obtained from Visakha Eye Hospital, Visakhapatnam, India, is used to verify the performance of the suggested model. The recommended approach is also verified on the glaucoma subset of High-Resolution Fundus (HRF) database. The experimental results of both the databases demonstrate that the CDR value is computed accurately with low computational time.
Title: Real Time Retinal Optic Disc Segmentation via Guided filter and Discrete Wavelet Transform
Description:
Abstract
In the world, glaucoma is the one of the main causes for loosing vision.
Optical Coherence Tomography or fundus camera is utilized to capture the optic disc and optic cup images.
For the detection of glaucoma and afterwards monitoring the patients, investigation of the head of optic nerve or cup-to-disc ratio (CDR) is an important factor.
For computing the CDR value, segmentation of optic disc and optic cup are utilized for the isolation of the relevant parts of the fundus image.
Even though ophthalmologists are computing the CDR value physically, however, it limits the identification of glaucoma at the early stage.
The accurate value of CDR is hard to find out if the optic cup and optic disc are not well defined properly.
Thus, this paper has suggested a combined model of Guided filter and Discrete Wave Transform (DWT) for the enhancement and OD segmentation.
Hysteresis thresholding is utilized for the optic cup segmentation.
A set of 50 images of 25 patients are obtained from Visakha Eye Hospital, Visakhapatnam, India, is used to verify the performance of the suggested model.
The recommended approach is also verified on the glaucoma subset of High-Resolution Fundus (HRF) database.
The experimental results of both the databases demonstrate that the CDR value is computed accurately with low computational time.
Related Results
Retinal Oximetry
Retinal Oximetry
Abstract.Purpose:Malfunction of retinal blood flow or oxygenation is believed to be involved in various diseases. Among them are retinal vessel occlusions, diabetic retinopathy and...
Differentiation between causes of optic disc swelling using retinal layer shape features
Differentiation between causes of optic disc swelling using retinal layer shape features
<p>The optic disc is the region of the retina where the optic nerve exits the back of the eye. A number of conditions can cause the optic disc to swell. Papilledema, optic di...
Performance Comparison of Hartley Transform with Hartley Wavelet and Hybrid Hartley Wavelet Transforms for Image Data Compression
Performance Comparison of Hartley Transform with Hartley Wavelet and Hybrid Hartley Wavelet Transforms for Image Data Compression
This paper proposes image compression using Hybrid Hartley wavelet transform. The paper compares the results of Hybrid Hartley wavelet transform with that of orthogonal Hartley tra...
Woningcorporaties en Vastgoedontwikkeling
Woningcorporaties en Vastgoedontwikkeling
This summary highlights the findings of the PhD-thesis ‘Woningcorporaties en Vastgoedontwikkeling: Fit for Use’ (‘Housing associations and Real Estate Development: Fit for Use?’). ...
Optic disc centered imaging versus quadrant imaging in retinal oximetry
Optic disc centered imaging versus quadrant imaging in retinal oximetry
Abstract
We aimed to compare intra eye quadrant variation in retinal vessel oxygen saturation in optic disc centered versus quadrant imaging. Forty two consecutive ...
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Neuritis optik idiopatik dengan penyerta central serous chorioretinopathy sebagai manifestasi chronic relapsing inflammatory optic neuropathy: Sebuah laporan kasus
Introduction: Idiopathic optic neuritis is an optic neuropathy with characteristics of optic nerve dysfunction that can be caused by various disorders of the optic nerve, including...
A Practical Guide to Measuring Optic Disc Size and its Clinical Correlation in Diagnosing Glaucoma for the Eye Care Professional
A Practical Guide to Measuring Optic Disc Size and its Clinical Correlation in Diagnosing Glaucoma for the Eye Care Professional
This study examines the connection between glaucoma and the optic disc, cup, and neuroretinal rim size. The use of a slit-lamp and funduscopy lens as a technique for determining an...
Retinal vessel segmentation driven by structure prior tokens
Retinal vessel segmentation driven by structure prior tokens
Abstract
Background
Accurate retinal vessel segmentation from Optical Coherence Tomography Angiography (OCTA) images is v...

