Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Structural Behavior of Pre-Loaded Fire-Damaged RC Columns Rehabilitated with UHPC

View through CrossRef
This study presents an experimental investigation into the rehabilitation of fire-damaged reinforced concrete (RC) columns using Ultra-High-Performance Concrete (UHPC) under an eccentric load of (e = 45 mm). The experimental program comprised nine small-scale RC column specimens, which were divided into two groups based on exposure temperatures of 500 °C and 700 °C, applied using a specially designed furnace. A control column that was not exposed to fire was also tested for comparison. The study included two fire exposure durations: 60 and 120 min. During the heating phase, the columns were subjected to a pre-applied axial load equal to 50% of their ultimate capacity (Pu). After sustaining fire-induced damage, the columns were rehabilitated using UHPC jacketing. The experimental results revealed a reduction in the ultimate load-carrying capacity of the RC columns with increasing fire temperature and exposure duration. Specifically, the load capacity decreased by 22.68% and 33.89% when exposed to 500 °C for 60 and 120 min, respectively, and by 42.02% and 49.02% when exposed to 700 °C for 60 and 120 min, respectively, compared with the control column. However, strengthening the fire-damaged columns with UHPC significantly enhanced their structural performance, resulting in an increase in ultimate load capacity ranging from 81.88% to 157.14% compared with their corresponding fire-damaged unstrengthened specimens. Based on the experimental findings, the load lateral displacement response at mid-height, load–axial deformation curves, failure modes, ductility, and stiffness characteristics of the columns were analysed. The study concludes that the use of UHPC in rehabilitating fire-exposed columns substantially improves most of these structural properties.
Title: Structural Behavior of Pre-Loaded Fire-Damaged RC Columns Rehabilitated with UHPC
Description:
This study presents an experimental investigation into the rehabilitation of fire-damaged reinforced concrete (RC) columns using Ultra-High-Performance Concrete (UHPC) under an eccentric load of (e = 45 mm).
The experimental program comprised nine small-scale RC column specimens, which were divided into two groups based on exposure temperatures of 500 °C and 700 °C, applied using a specially designed furnace.
A control column that was not exposed to fire was also tested for comparison.
The study included two fire exposure durations: 60 and 120 min.
During the heating phase, the columns were subjected to a pre-applied axial load equal to 50% of their ultimate capacity (Pu).
After sustaining fire-induced damage, the columns were rehabilitated using UHPC jacketing.
The experimental results revealed a reduction in the ultimate load-carrying capacity of the RC columns with increasing fire temperature and exposure duration.
Specifically, the load capacity decreased by 22.
68% and 33.
89% when exposed to 500 °C for 60 and 120 min, respectively, and by 42.
02% and 49.
02% when exposed to 700 °C for 60 and 120 min, respectively, compared with the control column.
However, strengthening the fire-damaged columns with UHPC significantly enhanced their structural performance, resulting in an increase in ultimate load capacity ranging from 81.
88% to 157.
14% compared with their corresponding fire-damaged unstrengthened specimens.
Based on the experimental findings, the load lateral displacement response at mid-height, load–axial deformation curves, failure modes, ductility, and stiffness characteristics of the columns were analysed.
The study concludes that the use of UHPC in rehabilitating fire-exposed columns substantially improves most of these structural properties.

Related Results

Behaviour of Structural Elements Constructed and Rehabilitated With High Performance Concretes
Behaviour of Structural Elements Constructed and Rehabilitated With High Performance Concretes
<p>An extensive experimental investigation coupled with Code based/design-oriented analysis was conducted on the performance and application of high-performance concretes (HP...
Behaviour of Structural Elements Constructed and Rehabilitated With High Performance Concretes
Behaviour of Structural Elements Constructed and Rehabilitated With High Performance Concretes
<p>An extensive experimental investigation coupled with Code based/design-oriented analysis was conducted on the performance and application of high-performance concretes (HP...
Experimental research on compressive strength of UHPC spherical hinge
Experimental research on compressive strength of UHPC spherical hinge
Purpose In order to reduce the impact of bridge construction on traffic under the bridge, the construction of bridges for some important traffic nodes usually adopts the swivel con...
Durable Bridge Columns using Stay-In-Place UHPC Shells for Accelerated Bridge Construction
Durable Bridge Columns using Stay-In-Place UHPC Shells for Accelerated Bridge Construction
Ultra-high performance concrete (UHPC) is a durable material that allows the construction of innovative structural elements and conforms with accelerated bridge construction (ABC) ...
Exploration of Ultra-High Performance Concrete (UHPC) Application in Nuclear Power Plant Structures
Exploration of Ultra-High Performance Concrete (UHPC) Application in Nuclear Power Plant Structures
Abstract Ultra-High Performance Concrete (UHPC), as a rapidly developing high-performance cement-based material in recent years, has three major characteristics: hig...
Strength analysis of concrete-encased cellular steel columns
Strength analysis of concrete-encased cellular steel columns
This research investigates the compression behavior of bare cellular steel columns and concrete-encased cellular steel (CECS) columns subjected to concentric and eccentric loadings...
A Review on Behavior and Fatigue Performance of Orthotropic Steel–UHPC Composite Deck
A Review on Behavior and Fatigue Performance of Orthotropic Steel–UHPC Composite Deck
Although orthotropic steel decks (OSDs) have been widely used in the construction of long-span bridges, there are frequently reported fatigue cracks after years of operation, and t...

Back to Top