Javascript must be enabled to continue!
Lifetime Estimation Based Health Index and Conditional Factor for Underground Cable System
View through CrossRef
In this paper, a lifetime estimation method for underground cable systems is proposed by combining a health index (HI) and conditional factor (CF). The underground cable system consists of underground cable, joint, termination, manhole, and duct bank. The HI is an indicator to indicate the actual condition of underground cable components and systems whereas the CF is used to indicate different operating stresses of the system under different operating conditions such as percentage loading, electrical stresses, laying structure, environment, etc. The actual technical data as well as historical operating and testing records are applied. The weighting and scoring method with the analytical hierarchy process are used to classify an importance of underground cable components, testing methods, and criteria used in the HI and CF calculation. The annual calculated HIs are plotted to investigate the lifetime trending curve by using a polynomial function. The degradation curve based on calculated CF is estimated by using the Weibull distribution function. Finally, the remaining life of the underground cable system is determined by matching the lifetime trending curve with the degradation curve. Ten practical underground cable systems supplying power in a high voltage power delivery system are evaluated with effective results. The lifetime of the underground cable system can be successfully estimated.
Title: Lifetime Estimation Based Health Index and Conditional Factor for Underground Cable System
Description:
In this paper, a lifetime estimation method for underground cable systems is proposed by combining a health index (HI) and conditional factor (CF).
The underground cable system consists of underground cable, joint, termination, manhole, and duct bank.
The HI is an indicator to indicate the actual condition of underground cable components and systems whereas the CF is used to indicate different operating stresses of the system under different operating conditions such as percentage loading, electrical stresses, laying structure, environment, etc.
The actual technical data as well as historical operating and testing records are applied.
The weighting and scoring method with the analytical hierarchy process are used to classify an importance of underground cable components, testing methods, and criteria used in the HI and CF calculation.
The annual calculated HIs are plotted to investigate the lifetime trending curve by using a polynomial function.
The degradation curve based on calculated CF is estimated by using the Weibull distribution function.
Finally, the remaining life of the underground cable system is determined by matching the lifetime trending curve with the degradation curve.
Ten practical underground cable systems supplying power in a high voltage power delivery system are evaluated with effective results.
The lifetime of the underground cable system can be successfully estimated.
Related Results
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Alternative Entrances: Phillip Noyce and Sydney’s Counterculture
Phillip Noyce is one of Australia’s most prominent film makers—a successful feature film director with both iconic Australian narratives and many a Hollywood blockbuster under his ...
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Deep Learning Training Model Construction and Optimization of Cable Size Features in 3D Point Cloud Data
Cables are widely used in power transmission, and the measurement of key dimensions of cables is an indispensable part of the cable preparation process to help ensure their quality...
Empowering Underground Laboratories Network Usage in the Baltic Sea Region
Empowering Underground Laboratories Network Usage in the Baltic Sea Region
<p>In the Baltic Sea region, there are world leading science organisations and industrial companies specialised in geophysics, geology and underground construction. T...
The life cycle of cable bacteria
The life cycle of cable bacteria
Cable bacteria are multicellular filamentous microorganisms that perform electrogenic sulphur oxidation, coupling the oxidation of sulphide in deeper sediments to oxygen reduction ...
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
INFLUENCE OF THE AMBIENT TEMPERATURE ON THE MECHANICAL TENSION OF THE OPTICAL CABLE
To ensure the quality and reliability of the fiber-optic communication line during the exploitation, it is necessary to constantly monitor the technical condition of the optical ca...
Dynamic Risk Assessment of Cable Duct Fires in Urban Underground Utility Tunnels Based on Dynamic Bayesian Networks
Dynamic Risk Assessment of Cable Duct Fires in Urban Underground Utility Tunnels Based on Dynamic Bayesian Networks
With the large-scale construction and operation of urban underground utility tunnels in China, the associated safety issues cannot be ignored. This paper proposes a risk assessment...
Underground Blowouts In Deep Well Drilling
Underground Blowouts In Deep Well Drilling
ABSTRACT
A kick occurs when the wellbore pressure becomes less than the formation pressure, and formation fluid enters the wellbore. When the flow of formation fl...
ACKNOWLEDGMENTS
ACKNOWLEDGMENTS
The UP Manila Health Policy Development Hub recognizes the invaluable contribution of the participants in theseries of roundtable discussions listed below:
RTD: Beyond Hospit...

