Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A case of Unicuspid Aortic Valve with Hidden Subaortic Ridge

View through CrossRef
57-years old man presented with exertional dyspnea. An early systolic murmur was heard over the aortic areas 2D and 3D Echocardiography revealed unicuspid , unicommissural aortic valve (UAV) with a characteristic “teardrop” lateral orifice (Figure A) and moderate valve stenosis (3D planimetered aortic valve area (AVA) is 1.1cm2) (Figure B) Continuous wave Doppler across aortic valve (AV) showed high peak and mean systolic gradients of 85 and 60mmHg respectively.(Figure C). 2D /3D Transesophageal Echocardiography (TOE) revealed a subaortic ridge attached to the posterior annulus (Arrow) (Figure D) Further En-face viewing of the aortic valve from the left ventricular outflow tract (LVOT) perspective showed a shelf-like ridge extending from the commissure to the cusp (Arrow) (Figure E) Zoomed mode of the aortic- LVOT junction confirmed the presence of the subaortic ridge seen attached to the posterior aortic annulus near the commissural opening (Figure F) The patient was referred for surgical consultation .. Unicupid aortic valve (UAV) is a rare congenital anomaly that has.2 subtypes ; unicomissural and acommissural subtypes. Both can present with variable degrees of the aortic stenosis (AS) and/or aortic valve regurgitation (AR).UAV has more early, accelerated and severe valvular degeneration in addition to smaller orifice in comparison with bicuspid and tricuspid aortic valve. Echocardiography is the gold standard for diagnosis and evaluation of the AV morphology and function and the associated disorders such as ventricular septal defect , aortopathy and subaortic obstruction.. Surgical aortic valve replacement (AVR) and repair of the associated anomalies are the most common treatment modality .
Title: A case of Unicuspid Aortic Valve with Hidden Subaortic Ridge
Description:
57-years old man presented with exertional dyspnea.
An early systolic murmur was heard over the aortic areas 2D and 3D Echocardiography revealed unicuspid , unicommissural aortic valve (UAV) with a characteristic “teardrop” lateral orifice (Figure A) and moderate valve stenosis (3D planimetered aortic valve area (AVA) is 1.
1cm2) (Figure B) Continuous wave Doppler across aortic valve (AV) showed high peak and mean systolic gradients of 85 and 60mmHg respectively.
(Figure C).
2D /3D Transesophageal Echocardiography (TOE) revealed a subaortic ridge attached to the posterior annulus (Arrow) (Figure D) Further En-face viewing of the aortic valve from the left ventricular outflow tract (LVOT) perspective showed a shelf-like ridge extending from the commissure to the cusp (Arrow) (Figure E) Zoomed mode of the aortic- LVOT junction confirmed the presence of the subaortic ridge seen attached to the posterior aortic annulus near the commissural opening (Figure F) The patient was referred for surgical consultation .
Unicupid aortic valve (UAV) is a rare congenital anomaly that has.
2 subtypes ; unicomissural and acommissural subtypes.
Both can present with variable degrees of the aortic stenosis (AS) and/or aortic valve regurgitation (AR).
UAV has more early, accelerated and severe valvular degeneration in addition to smaller orifice in comparison with bicuspid and tricuspid aortic valve.
Echocardiography is the gold standard for diagnosis and evaluation of the AV morphology and function and the associated disorders such as ventricular septal defect , aortopathy and subaortic obstruction.
Surgical aortic valve replacement (AVR) and repair of the associated anomalies are the most common treatment modality .

Related Results

Unicuspid unicommissural aortic valves: A surgical pathology analysis
Unicuspid unicommissural aortic valves: A surgical pathology analysis
ABSTRACT The unicuspid unicommisural aortic valve is an uncommon congenital malformation that often manifests as stenosis with or without regurgitation in adults in their...
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Abstract 4369914: Successful Transfemoral TAVR in a Patient with Chronic Aortic Dissection and Severe Aortic Insufficiency
Transcatheter aortic valve replacement is a well-established treatment for high-surgical-risk patients with severe aortic disease, providing a less invasive alternative to traditio...
Congenital calcified unicuspid aortic valve with isolated aortic insufficiency without stenosis, and calcific retinal emboli
Congenital calcified unicuspid aortic valve with isolated aortic insufficiency without stenosis, and calcific retinal emboli
Unicuspid aortic valve (UAV) is a very rare congenital anomaly with an estimated prevalence of 1 in 5000 in the adult population. It is often diagnosed by a 2D or 3D Transthoracic ...
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
AORTIC ROOT ANEURYSM OR ECTASIA TREATED WITH AORTIC ROOT WRAPPED PROCEDURE
Objectives To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia. ...
Aortic root wrapped procedure
Aortic root wrapped procedure
Objective To develop a relatively simple and effective and less risk operation, aortic root wrapped procedure, to treat with aortic root aneurysm or ectasia. ...
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Blood pressure, hypertension, and the risk of aortic aneurysm in the UK Biobank
Abstract Background Although an association between elevated blood pressure and risk of aortic aneurysm is established, f...

Back to Top