Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Establishment of Pulsed X-Ray Reference Radiation Field and Measurement of Related Parameters

View through CrossRef
The international research on radiation protection dosimetry mainly focuses on continuous radiation. However, pulsed radiation has been widely used in the fields of new detector development, radiographic inspection, X-ray diagnosis, nuclear accident emergency and scientific research, the measurement of pulsed dose (rate) is very difficult. In order to solve the technical problem of pulse response test of active radiation dosimeter, the generation principle of pulsed X-ray and gamma ray radiation field is discussed, and the reference radiation field of pulsed X-ray is established based on three kinds of X-ray machines. Combined with the secondary standard ionization chamber and pulse width measurement system, the research of pulsed radiation dose (rate) measurement technology is carried out. The experimental results show that the pulse width of the established pulsed X-ray reference radiation field can be adjusted between 50 ns-10 s, and the instantaneous dose rate range is 2.5 mSv/h-6.7 × 10<sup>5</sup> Sv/h, which can be widely used to study the pulsed X-ray response characteristics of active radiation dosimeter. This work can be widely used to study the pulsed X-ray response characteristics of active radiation dosimeter, which is of great significance to solve the calibration problem of pulsed radiation dose monitoring instrument.
Title: Establishment of Pulsed X-Ray Reference Radiation Field and Measurement of Related Parameters
Description:
The international research on radiation protection dosimetry mainly focuses on continuous radiation.
However, pulsed radiation has been widely used in the fields of new detector development, radiographic inspection, X-ray diagnosis, nuclear accident emergency and scientific research, the measurement of pulsed dose (rate) is very difficult.
In order to solve the technical problem of pulse response test of active radiation dosimeter, the generation principle of pulsed X-ray and gamma ray radiation field is discussed, and the reference radiation field of pulsed X-ray is established based on three kinds of X-ray machines.
Combined with the secondary standard ionization chamber and pulse width measurement system, the research of pulsed radiation dose (rate) measurement technology is carried out.
The experimental results show that the pulse width of the established pulsed X-ray reference radiation field can be adjusted between 50 ns-10 s, and the instantaneous dose rate range is 2.
5 mSv/h-6.
7 × 10<sup>5</sup> Sv/h, which can be widely used to study the pulsed X-ray response characteristics of active radiation dosimeter.
This work can be widely used to study the pulsed X-ray response characteristics of active radiation dosimeter, which is of great significance to solve the calibration problem of pulsed radiation dose monitoring instrument.

Related Results

A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
A Method for Determining the Porosity of Pulsed Neutron by Combining Gamma Energy and Time Spectrum
Pulsed-neutron gamma energy spectroscopy and neutron lifetime measurement systems enable the evaluation of the elemental content, saturation. And recent studies have demonstrated t...
A method of calibrating effective area of focusing X-ray detector by using normal spectrum of Crab pulsar
A method of calibrating effective area of focusing X-ray detector by using normal spectrum of Crab pulsar
X-ray detector is a core component for X-ray astronomical observation and pulsar navigation.The on-orbit observation performance of X-ray detector will change gradually,owing to th...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
Hidden Radiation Exposure: Daily Life vs Medical Imaging
Hidden Radiation Exposure: Daily Life vs Medical Imaging
Radiation is a natural and unavoidable part of human life, present in the environment as well as in medical imaging procedures. While many people fear radiation from diagnostic ima...
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
Effect of frequency difference deviation on full-field heterodyne measurement accuracy
With the advantages of high precision and great environmental adaptability, laser heterodyne interferometry has been successfullyused in some areas, such as measuring distance and ...
Characteristics of solar radiation at Xiaotang, in the northern marginal zone of the Taklimakan Desert
Characteristics of solar radiation at Xiaotang, in the northern marginal zone of the Taklimakan Desert
The characteristics of solar radiation and the influence of sand and dust on solar radiation in the northern margin of Taklimakan Desert were analyzed using radiation observation d...
PENGARUH PELATIHAN PROTEKSI RADIASI TERHADAP BUDAYA KESELAMATAN RADIASI
PENGARUH PELATIHAN PROTEKSI RADIASI TERHADAP BUDAYA KESELAMATAN RADIASI
Radiology examination in Indonesia is bound by radiation protection policy. Radiographers, as radiation workers, must ensure radiation safety during radiology examinations. A stron...

Back to Top