Javascript must be enabled to continue!
Introducing Data-Driven Virtual Viscosity Measurements
View through CrossRef
Abstract
Polymer-based chemical flooding is a mature enhanced oil recovery technology that has proven to result in significant incremental oil recovery that is both cost and GHG emission-competitive compared to the oil recovered by conventional waterflooding. For such chemical flooding projects, controlling the viscosity of injected polymer solution is critical because the polymer cost is one of the most significant cost elements in the project economics. The polymer viscosity is routinely measured in the laboratory using fluid samples taken manually at different sampling points (i.e., polymer preparation facilities, injecting lines, and well heads). However, in the case of large-scale projects, such viscosity monitoring becomes time-consuming and requires dedicated field staff. Moreover, the quality of laboratory-measured viscosity is questionable due to the potential viscosity degradation caused by the oxygen ingress or polymer shearing during sampling, storage, and measurement. The inline viscometers were introduced to improve the reliability of viscosity measurements and have a better quality of viscosity monitoring. Such viscometers are relatively simple devices readily available on the market from several vendors. However, the device comes at additional costs and requires modifications at the tie-in point (bypass line, drainage, and (sometimes) communication and power lines). On top of it, operational costs include regular maintenance that the inline viscometer requires to ensure good data quality.
This study introduces a data-driven Virtual Viscosity Meter (VVM) as a tool to augment the inline and laboratory viscosity measurements. Standard injector wells in a field are equipped with gauges that report injection rate, well/tubing head pressure, and temperature of the injected fluid. With such well data and viscosity measurements, calculating the viscosity becomes a machine learning regression problem. Training the machine learning regression methods on the actual inline and laboratory-measured polymer viscosity has demonstrated that VVM is a promising, high-accuracy solution with a low computational cost. The possibility of further implementing this approach to calculate the viscosity of an injected fluid was investigated using the data from several projects. Finally, the application of the VVM tool for viscosity monitoring and the limitations of VVM were discussed.
Title: Introducing Data-Driven Virtual Viscosity Measurements
Description:
Abstract
Polymer-based chemical flooding is a mature enhanced oil recovery technology that has proven to result in significant incremental oil recovery that is both cost and GHG emission-competitive compared to the oil recovered by conventional waterflooding.
For such chemical flooding projects, controlling the viscosity of injected polymer solution is critical because the polymer cost is one of the most significant cost elements in the project economics.
The polymer viscosity is routinely measured in the laboratory using fluid samples taken manually at different sampling points (i.
e.
, polymer preparation facilities, injecting lines, and well heads).
However, in the case of large-scale projects, such viscosity monitoring becomes time-consuming and requires dedicated field staff.
Moreover, the quality of laboratory-measured viscosity is questionable due to the potential viscosity degradation caused by the oxygen ingress or polymer shearing during sampling, storage, and measurement.
The inline viscometers were introduced to improve the reliability of viscosity measurements and have a better quality of viscosity monitoring.
Such viscometers are relatively simple devices readily available on the market from several vendors.
However, the device comes at additional costs and requires modifications at the tie-in point (bypass line, drainage, and (sometimes) communication and power lines).
On top of it, operational costs include regular maintenance that the inline viscometer requires to ensure good data quality.
This study introduces a data-driven Virtual Viscosity Meter (VVM) as a tool to augment the inline and laboratory viscosity measurements.
Standard injector wells in a field are equipped with gauges that report injection rate, well/tubing head pressure, and temperature of the injected fluid.
With such well data and viscosity measurements, calculating the viscosity becomes a machine learning regression problem.
Training the machine learning regression methods on the actual inline and laboratory-measured polymer viscosity has demonstrated that VVM is a promising, high-accuracy solution with a low computational cost.
The possibility of further implementing this approach to calculate the viscosity of an injected fluid was investigated using the data from several projects.
Finally, the application of the VVM tool for viscosity monitoring and the limitations of VVM were discussed.
Related Results
New Compositional Models for Calculating Viscosity of Crude Oils
New Compositional Models for Calculating Viscosity of Crude Oils
Abstract
Crude oil viscosity is an important physical property that controls and influences the flow of oil through porous media and pipelines. Hence, it is the b...
Introducing the Vibrating Wire Viscometer for Wireline Formation Testing: In-Situ Viscosity
Introducing the Vibrating Wire Viscometer for Wireline Formation Testing: In-Situ Viscosity
Abstract
A vibrating wire (VW) viscometer is introduced for the in-situ measurement of formation fluid viscosity. This is the first time this simple and robust techn...
Coupled Marangoni-Benard/Rayleigh-Benard Instability With Temperature Dependent Viscosity
Coupled Marangoni-Benard/Rayleigh-Benard Instability With Temperature Dependent Viscosity
Abstract
The onset of convection induced by coupled surface tension gradient and buoyancy forces is investigated with temperature dependent viscosity. Both surfac...
Anaerobic Thermal Stability Testing of Polymers Under High Salinity and Temperature Conditions for EOR Applications
Anaerobic Thermal Stability Testing of Polymers Under High Salinity and Temperature Conditions for EOR Applications
Abstract
Enhanced oil recovery (EOR) is a technique used to increase oil production from a reservoir. This study primarily focuses on chemical EOR using polymer f...
Investigating the Viscosity Structure of Venus
Investigating the Viscosity Structure of Venus
The interior structure and geodynamic style of Venus are largely unknown. One of the most informative ways available to investigate the planet’s interior is through the joint analy...
Viiscosity of Gas-saturated Bitumen
Viiscosity of Gas-saturated Bitumen
Abstract
The objective of this work was to measure the effect of dissolved carbon dioxide, methane and nitrogen on the viscosity of Athabasca bitumen. To accompli...
Abnormal viscosity changes in high-temperature metallic melts
Abnormal viscosity changes in high-temperature metallic melts
The viscosity of high-temperature metallic melt, which is an important index for evaluating dynamics of liquid melt, is one of the basic physical properties. It not only influences...
EFEKTIFITAS PELATIHAN LABORATORIUM VIRTUAL SEBAGAI MEDIA PEMBELAJARAN BAGI GURU KIMIA
EFEKTIFITAS PELATIHAN LABORATORIUM VIRTUAL SEBAGAI MEDIA PEMBELAJARAN BAGI GURU KIMIA
EFFECTIVITY OF VIRTUAL LABORATORY TRAINING AS A LEARNING MEDIA FOR CHEMISTRY TEACHERSAchmad Lutfi, SukarminUniversitas Negeri Surabaya, Indonesia achmadlutfi@unesa.ac.idAbstractThe...

