Javascript must be enabled to continue!
Pelvic antropometric measurement in 3D CT for placement of two unilateral iliosacral S1 - 7.3 mm screws
View through CrossRef
Abstract
Purpose
Stability of the dorsal pelvic ring is important for patient mobilisation and can be restored using several surgical procedures after fracture. Placement of percutaneous iliosacral screws is a reliable and minimal-invasive technique to achieve stabilisation of the dorsal pelvic ring by placement of two screws in the first sacral vertebra. Aim of this study was to evaluate 3D CT scans regarding the anatomical possibility to place two 7.3 mm iliosacral screws for fixation of the dorsal pelvic ring.
Methods
3D CT datasets of 500 consecutive trauma patients with 1000 hemipelves of a mid-european level I trauma centre with or without pelvic injury were evaluated and measured bilaterally in this retrospective study.
Results
One thousand hemipelvic datasets of 500 patients (157 females, 343 males) with a mean age of 49.7 years (18 to 95) were included in this study. Only 16 hemipelves (1.6%, 11 in females, 5 in males) in 14 patients (2.8%, 9 females = 5.73%, 5 males = 1.5%) showed too narrow corridors so that 7.3 mm screw placement would not be possible (p = 0.001). In women, too narrow corridors occurred 3.9 times as often as in men. Only two females showed this bilaterally.
Conclusion
The evaluation of 3D CT scans of the pelvis showed the importance of planning iliosacral screw placement, especially if two 7.3 mm screws are intended to be placed in the first sacral vertebra.
Springer Science and Business Media LLC
Title: Pelvic antropometric measurement in 3D CT for placement of two unilateral iliosacral S1 - 7.3 mm screws
Description:
Abstract
Purpose
Stability of the dorsal pelvic ring is important for patient mobilisation and can be restored using several surgical procedures after fracture.
Placement of percutaneous iliosacral screws is a reliable and minimal-invasive technique to achieve stabilisation of the dorsal pelvic ring by placement of two screws in the first sacral vertebra.
Aim of this study was to evaluate 3D CT scans regarding the anatomical possibility to place two 7.
3 mm iliosacral screws for fixation of the dorsal pelvic ring.
Methods
3D CT datasets of 500 consecutive trauma patients with 1000 hemipelves of a mid-european level I trauma centre with or without pelvic injury were evaluated and measured bilaterally in this retrospective study.
Results
One thousand hemipelvic datasets of 500 patients (157 females, 343 males) with a mean age of 49.
7 years (18 to 95) were included in this study.
Only 16 hemipelves (1.
6%, 11 in females, 5 in males) in 14 patients (2.
8%, 9 females = 5.
73%, 5 males = 1.
5%) showed too narrow corridors so that 7.
3 mm screw placement would not be possible (p = 0.
001).
In women, too narrow corridors occurred 3.
9 times as often as in men.
Only two females showed this bilaterally.
Conclusion
The evaluation of 3D CT scans of the pelvis showed the importance of planning iliosacral screw placement, especially if two 7.
3 mm screws are intended to be placed in the first sacral vertebra.
Related Results
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
Variables Associated With Loss of Fixation of Retrograde Rami Screws in Minimally Displaced Lateral Compression Type 1 Pelvic Ring Injuries
OBJECTIVES:
To evaluate variables associated with loss of fixation of retrograde rami screws in the treatment of stress-positive minimally displaced lateral compression...
A Retrospective Analysis of S2 Iliosacral Screw Fixation Using Robot-Assisted Navigation for Unstable Pelvic Injuries and Sacral Dysmorphism: a Report of 16 Cases
A Retrospective Analysis of S2 Iliosacral Screw Fixation Using Robot-Assisted Navigation for Unstable Pelvic Injuries and Sacral Dysmorphism: a Report of 16 Cases
Objective The second sacral segment iliosacral screw (S2 screw) insertion is a demanding technique, with a high rate of screw malposition due to the complex pelvic anatomy. TiRobot...
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
(087) Why Should Pelvic Floor Physical Therapy be Included in Treatment of Vestibulodynia?
Abstract
Introduction
Vestibulodynia, vulvar pain localized to the vestibule without an identifiable cause, has a multifactorial...
CAN THE SAGITTAL PELVIC TILT BE PREDICTED FROM ANTEROPOSTERIOR PELVIC RADIOGRAPHS?
CAN THE SAGITTAL PELVIC TILT BE PREDICTED FROM ANTEROPOSTERIOR PELVIC RADIOGRAPHS?
The relevance of the hip-spine interaction in understanding the biomechanical behavior of the hip has led to surgeons assessing spinopelvic characteristics prior to total hip arthr...
Pelvic Stabilization Versus PNF for Pain, Disability, and Leg Length in Anterior Innominate Iliosacral Dysfunction
Pelvic Stabilization Versus PNF for Pain, Disability, and Leg Length in Anterior Innominate Iliosacral Dysfunction
Background: Anterior innominate iliosacral dysfunction is a biomechanical condition of the sacroiliac joint (SIJ) associated with altered pelvic alignment, localized pain, and func...
Evaluasi KIPPas (Kartu Instrumen Prediktor Pangastuti) Jogja sebagai Instrumen Prediktor Disfungsi Dasar Panggul Pasca Persalinan Vaginal
Evaluasi KIPPas (Kartu Instrumen Prediktor Pangastuti) Jogja sebagai Instrumen Prediktor Disfungsi Dasar Panggul Pasca Persalinan Vaginal
Background: Postpartum pelvic floor dysfunction is pelvic floor disorder, which can be in the form of pelvic organ prolapse, urinary problem, defecation problem or sexual dysfuncti...
The Muscle Cells in Pelvic Floor Dysfunctions: Systematic Review
The Muscle Cells in Pelvic Floor Dysfunctions: Systematic Review
Background/Aims: The pelvic floor muscles are important structures involved in pelvic floor tone, pelvic organ support, and continence. The aim of this study was to perform an upda...
Identification of Safe Channels for Screws in the Anterior Pelvic Ring Fixation System
Identification of Safe Channels for Screws in the Anterior Pelvic Ring Fixation System
Abstract
Background: There have been few studies on insertion of fixation screws for the anterior pelvic ring system. Objective: To identify safe channels for fixation scre...