Javascript must be enabled to continue!
Modern nickel-titanium rotary systems in endodontic treatment
View through CrossRef
Background: One of the most important steps in endodontic treatment is the preparation of a uniform space, the use of endodontic irrigant and creating space for the endodontic filling. Therefore, improving endodontic treatment techniques is one of the most important tasks of modern dentistry. The success and effectiveness of endodontic treatment is largely determined by the quality of chemo-mechanical root canal treatment. In recent years there has been a major emphasis on the use of rotary mechanical instrumentation systems, namely the use of nickel-titanium (NiTi) alloys, which due to their properties represent a favorable flexibility in the instrumentation of difficult anatomies. Material and methods: 20 patients were examined and treated. They were divided into 2 groups: for the treatment of 6 patients was applied the Protaper Universal rotary system. In the second group of 14 patients to whom mechanical instrumentation was applied, were 7 patients following the Protaper Next and the other 7 Dc Taper with different pulpal and periodontal diseases. Results: Mechanical instrumentation was performed on different nosological entities, the prevalence being acute pulpitis. Among instrumented teeth, the prevalence was on the side of pluriradicular teeth. Conclusions: The practical application of different NiTi rotary systems has to be determined individually, as each clinical case has its own practical properties. But the success of an endodontic treatment depends not only on the rotary instruments used and, on the method, chosen, but also on the practitioner’s experience, detailed knowledge of the properties and step-by-step instrumentation protocols.
State Enterprise "Revista Curier Medical"
Title: Modern nickel-titanium rotary systems in endodontic treatment
Description:
Background: One of the most important steps in endodontic treatment is the preparation of a uniform space, the use of endodontic irrigant and creating space for the endodontic filling.
Therefore, improving endodontic treatment techniques is one of the most important tasks of modern dentistry.
The success and effectiveness of endodontic treatment is largely determined by the quality of chemo-mechanical root canal treatment.
In recent years there has been a major emphasis on the use of rotary mechanical instrumentation systems, namely the use of nickel-titanium (NiTi) alloys, which due to their properties represent a favorable flexibility in the instrumentation of difficult anatomies.
Material and methods: 20 patients were examined and treated.
They were divided into 2 groups: for the treatment of 6 patients was applied the Protaper Universal rotary system.
In the second group of 14 patients to whom mechanical instrumentation was applied, were 7 patients following the Protaper Next and the other 7 Dc Taper with different pulpal and periodontal diseases.
Results: Mechanical instrumentation was performed on different nosological entities, the prevalence being acute pulpitis.
Among instrumented teeth, the prevalence was on the side of pluriradicular teeth.
Conclusions: The practical application of different NiTi rotary systems has to be determined individually, as each clinical case has its own practical properties.
But the success of an endodontic treatment depends not only on the rotary instruments used and, on the method, chosen, but also on the practitioner’s experience, detailed knowledge of the properties and step-by-step instrumentation protocols.
Related Results
Impact of Ni Doping on the Microstructure and Mechanical Properties of TiB2 Films
Impact of Ni Doping on the Microstructure and Mechanical Properties of TiB2 Films
The TiB2 film exhibits exceptional hardness and chemical stability due to its unique crystal structure and robust covalent bonds, but it also demonstrates high brittleness and poor...
A Review on Properties of Electrodeposited Nickel Composite Coatings: Ni-Al2O3, Ni-SiC, Ni-ZrO2, Ni-TiO2 and Ni-WC
A Review on Properties of Electrodeposited Nickel Composite Coatings: Ni-Al2O3, Ni-SiC, Ni-ZrO2, Ni-TiO2 and Ni-WC
Nickel electrodeposition is a widely utilized method for creating thin films on various substrates with various desirable attributes. Recently, there has been a growing interest in...
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
MODAL ANALISIS PADA ROTARY KILN DENGAN MENGGUNAKAN METODE ELEMEN HINGGA
This research is based on the general damage to the rotary kiln due to continuous use. Then the results from the burned in a Rotary Kiln So we need a prevention to overcome it. Tes...
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Discrete element parameter calibration and wear characteristics analysis of soil-rotary tillage blade in gneiss mountainous area
Abstract
Aiming at the problems of fast wear and short service life of rotary tillage blade in gneiss mountainous area, and the lack of accurate and reliable discrete eleme...
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
A Dynamic Analysis of the Rotary Cutting System of King Grass Shredder
With the rotary cutting system of king grass shredder as the research object, this paper established finite element models for rotating shaft, rotating shaft-belt pulley, rotating ...
Cyclic Fatigue of Different Ni-Ti Endodontic Rotary File Alloys: A Comprehensive Review
Cyclic Fatigue of Different Ni-Ti Endodontic Rotary File Alloys: A Comprehensive Review
Introduction: Modern endodontics aims to decrease the bacterial load from the complex endodontic space. Over the years, improvements in the operative phases have led to a considera...
Properties of Electrodeposited Nickel Composite Coatings: Ni-Al2O3, Ni-SiC, Ni-ZrO2, Ni-TiO2 and Ni-WC
Properties of Electrodeposited Nickel Composite Coatings: Ni-Al2O3, Ni-SiC, Ni-ZrO2, Ni-TiO2 and Ni-WC
Nickel electrodeposition is a widely utilized method for creating thin films on various substrates with various desirable attributes. Recently, there has been a growing interest in...
Allergenicity and Bioavailability of Nickel Nanoparticles Compared to Nickel Microparticles in Mice
Allergenicity and Bioavailability of Nickel Nanoparticles Compared to Nickel Microparticles in Mice
Metal allergy is a common disease that afflicts many people. Nevertheless, the mechanism underlying metal allergy development has not been completely elucidated. Metal nanoparticle...

