P3711Impact of peri-device leakage after interventional occlusion of the left atrial appendage: Results from the ORIGINAL registry (saxOnian RegIstry analyzinG and followINg left atrial Appendage cLosure)

View through CrossRef
Abstract Background Oral anticoagulation for prophylaxis of central and peripheral embolisation is limited in its use in patients with atrial fibrillation (AF) and bleeding events. As an alternative to anticoagulation, the interventional closure of the left atrial appendage (LAAO) is available. A common clinical dilemma is the treatment of patients with potential peri-device leakage following LAA occlusion. The specific definition of the severity of the leak and the long-term clinical implications have not yet been sufficiently investigated. Methods The multi-centre ORIGINAL registry was initiated 2014. The aim of this registry is to analyze the safety and efficacy of the procedure in patients with a high risk of bleeding in everyday clinical practice and to evaluate hemorrhagic and thromboemb. events in the long term follow-up. Patients with an indication for LAA occl. were included in the registry after informed consent. The impl., follow-up and anticoagulation regimens are performed according to the standard of the participating centers. 521 patients with AF underwent an implantation of an LAA closure device between Jul. 2014 and Nov. 2018. A mean follow-up of 463 days could be reached in 386 patients. Results The periprocedural complication rate was 3.8% of which 5 patients experienced pericardial effusion (successful treatment with pericardial puncture or surgical), 2 patients had periprocedural stroke and 1 patient suffered from air embolism. In 27 patients a peri-device flow due to incomplete occlusion was detected by TEE (5.4% of the implantations). The size ranged between 1 and 8 mm (mean 2.28 mm (SD=2.11)). The eccentricity index (EI) of the LAA in these patients was 1.22 (SD 0.17), and thus the LAA rather oval, while those LAA without leakage tend to be more circular (EI 1.08 with SD=0.17). 2 of the patients with leakage (7.4%) experienced stroke or peripheral embolism, respectively. The annual risk for stroke/TIA/peripheral embolism of these patients was 5.84%, the annual risk of the patients without leakage was 2.04%. Patients with a leakage >6 mm were treated with rivaroxaban in full therapeutic dosage. One patient underwent an additional procedure. Conclusion The evaluation and management of para-device leakage after an interventional LAA occlusion represents a challenge. Currently, limited data are available on the optimal strategy. Those data indicate that residual peri-device flow into the LAA after percutaneous closure with the Watchman device represents no cause for alarm. However, our data suggest, that patients with peridevice leak might be at a higher risk of thromboembolic events. Furthermore, it could be shown, that these patients had rather oval ostium of the LAA, while those LAA without leakage tend to be more circular. This implicates the importance of advanced imaging methods, such as 3D-TEE, which are capable to precisely determine the size of the LAA and the degree of its circularity. Acknowledgement/Funding None
Title: P3711Impact of peri-device leakage after interventional occlusion of the left atrial appendage: Results from the ORIGINAL registry (saxOnian RegIstry analyzinG and followINg left atrial Appendage cLosure)
Description:
Abstract Background Oral anticoagulation for prophylaxis of central and peripheral embolisation is limited in its use in patients with atrial fibrillation (AF) and bleeding events.
As an alternative to anticoagulation, the interventional closure of the left atrial appendage (LAAO) is available.
A common clinical dilemma is the treatment of patients with potential peri-device leakage following LAA occlusion.
The specific definition of the severity of the leak and the long-term clinical implications have not yet been sufficiently investigated.
Methods The multi-centre ORIGINAL registry was initiated 2014.
The aim of this registry is to analyze the safety and efficacy of the procedure in patients with a high risk of bleeding in everyday clinical practice and to evaluate hemorrhagic and thromboemb.
events in the long term follow-up.
Patients with an indication for LAA occl.
were included in the registry after informed consent.
The impl.
, follow-up and anticoagulation regimens are performed according to the standard of the participating centers.
521 patients with AF underwent an implantation of an LAA closure device between Jul.
2014 and Nov.
2018.
A mean follow-up of 463 days could be reached in 386 patients.
Results The periprocedural complication rate was 3.
8% of which 5 patients experienced pericardial effusion (successful treatment with pericardial puncture or surgical), 2 patients had periprocedural stroke and 1 patient suffered from air embolism.
In 27 patients a peri-device flow due to incomplete occlusion was detected by TEE (5.
4% of the implantations).
The size ranged between 1 and 8 mm (mean 2.
28 mm (SD=2.
11)).
The eccentricity index (EI) of the LAA in these patients was 1.
22 (SD 0.
17), and thus the LAA rather oval, while those LAA without leakage tend to be more circular (EI 1.
08 with SD=0.
17).
2 of the patients with leakage (7.
4%) experienced stroke or peripheral embolism, respectively.
The annual risk for stroke/TIA/peripheral embolism of these patients was 5.
84%, the annual risk of the patients without leakage was 2.
04%.
Patients with a leakage >6 mm were treated with rivaroxaban in full therapeutic dosage.
One patient underwent an additional procedure.
Conclusion The evaluation and management of para-device leakage after an interventional LAA occlusion represents a challenge.
Currently, limited data are available on the optimal strategy.
Those data indicate that residual peri-device flow into the LAA after percutaneous closure with the Watchman device represents no cause for alarm.
However, our data suggest, that patients with peridevice leak might be at a higher risk of thromboembolic events.
Furthermore, it could be shown, that these patients had rather oval ostium of the LAA, while those LAA without leakage tend to be more circular.
This implicates the importance of advanced imaging methods, such as 3D-TEE, which are capable to precisely determine the size of the LAA and the degree of its circularity.
Acknowledgement/Funding None.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Peri-implantitis: risk factors and outcome of reconstructive therapy
Peri-implantitis: risk factors and outcome of reconstructive therapy
This thesis is focused on (I) the outcome of reconstructive treatment of peri-implant defects and (II) risk factors for the development of peri-implantitis. Background An increas...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
Rethinking Anticoagulation in Kidney Disease and Kidney Transplantation
BackgroundA clinical dilemma exists in patients with CKD, ESKD, and after kidney transplantation, as they face concurrent risks of both thromboembolic and hemorrhagic complications...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Left Atrial Appendage Closure for Stroke Prevention
Left Atrial Appendage Closure for Stroke Prevention
Atrial fibrillation is the most common chronic arrhythmia worldwide, and stroke is its most common complication. Approximately 20% of all ischemic strokes attributed to atrial fibr...

Back to Top