Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems

View through CrossRef
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.
Title: Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems
Description:
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming.
Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate.
In addition to the issue of refrigerant high GWP, energy consumption is a significant issue.
The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source.
Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems.
Relevant thermodynamic equations and REFPROP software were employed for the computational analysis.
The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications.
The blends also exhibited low compressor energy input and low specific cooling energy.
R455A has an average coefficient of performance (COP) of 24.
6% above that of the reference refrigerant (R410A).
The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.
3, 6.
0, and 12.
6%, respectively than that of R410A.
Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy.
R455A also has the highest COP and relatively high cooling capacity per unit volume.

Related Results

Co-benefits of efficient and climate friendly cooling in China
Co-benefits of efficient and climate friendly cooling in China
The cooling sector plays a pivotal role in the global economy but significantly contributes to global warming. In 2022, cooling-related emissions accounted for 13% of global greenh...
Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Environmental concerns are driving regulations to reduce the use of hydrofluorocarbons (HFCs) with high global warming potential (GWP) as refrigerants in heat pumps. CO2 is an attr...
Estimating installed cooling capacities on city scale
Estimating installed cooling capacities on city scale
Heating and cooling of buildings is one of the largest final energy uses and largest sources of greenhouse gas emissions. To reduce the impact of heating and cooling on our climate...
Analysis of the dielectric properties of R410A Gas as an alternative to SF6 for high‐voltage applications
Analysis of the dielectric properties of R410A Gas as an alternative to SF6 for high‐voltage applications
Electric power industry is extensively using gas‐insulated systems for the transmission and distribution of electrical energy. In high‐voltage technology, the gas insulation is dom...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
British Food Journal Volume 48 Issue 4 1946
British Food Journal Volume 48 Issue 4 1946
The recent introduction of the Food Standards (Self‐Raising Flour) Order (S.R. & O. 1946 No. 157) heralds the passing of a period in which a most unfortunate state of affairs h...
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
Experimental Feasibility Study of Radial Injection Cooling of Three-Pad Air Foil Bearings
The foil bearing (FB) is one type of hydrodynamic bearing using air or another gas as a lubricant. When FBs are designed, installed, and operated properly, they are a very cost-eff...
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
The microclimate of livestock premises is determined by a set of physical, chemical and biological parameters inside the premises for keeping animals and is characterized by the fo...