Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems

View through CrossRef
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming. Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate. In addition to the issue of refrigerant high GWP, energy consumption is a significant issue. The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source. Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems. Relevant thermodynamic equations and REFPROP software were employed for the computational analysis. The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications. The blends also exhibited low compressor energy input and low specific cooling energy. R455A has an average coefficient of performance (COP) of 24.6% above that of the reference refrigerant (R410A). The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.3, 6.0, and 12.6%, respectively than that of R410A. Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy. R455A also has the highest COP and relatively high cooling capacity per unit volume.
Title: Energy and cooling performance of carbon-dioxide and hydrofluoroolefins blends as eco-friendly substitutes for R410A in air-conditioning systems
Description:
Air-conditioning and refrigeration systems are electrical appliances that use a huge amount of energy and contribute indirectly to global warming.
Also, R410A which was initially developed as a substitute for ozone-depleting refrigerants in the air-conditioning systems has been phase-out due to its high global warming potential (GWP) and the resulting harmful effect on the climate.
In addition to the issue of refrigerant high GWP, energy consumption is a significant issue.
The energy efficiency of new refrigerants must then be considered in the search for alternative refrigerants to ensure that they do not lead to an increase in greenhouse gas generation at the power source.
Therefore, this paper investigates the energy and cooling performance of four new multi-components and ecologically friendly refrigerant blends that contained carbon dioxide and hydrofluoroolefins in their compositions as substitutes for R410A in air-conditioning systems.
Relevant thermodynamic equations and REFPROP software were employed for the computational analysis.
The results indicated that the new blends (R445A, R455A, R470B and R470A) exhibited a desirable low compression ratio and high heat transfer for cooling applications.
The blends also exhibited low compressor energy input and low specific cooling energy.
R455A has an average coefficient of performance (COP) of 24.
6% above that of the reference refrigerant (R410A).
The cooling capacity per unit volume for R470B, R455A and R470A across a temperature range of 253 to 293 K are higher by 1.
3, 6.
0, and 12.
6%, respectively than that of R410A.
Generally, among all the four new substitute blends, the overall assessment revealed R455A as the best replacement for R410A in air-conditioning systems due to its superior performance in terms of its low compression ratio, compressor energy and specific cooling energy.
R455A also has the highest COP and relatively high cooling capacity per unit volume.

Related Results

Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Laboratory tests of a prototype carbon dioxide ground-source air conditioner
Environmental concerns are driving regulations to reduce the use of hydrofluorocarbons (HFCs) with high global warming potential (GWP) as refrigerants in heat pumps. CO2 is an attr...
Analysis of the dielectric properties of R410A Gas as an alternative to SF6 for high‐voltage applications
Analysis of the dielectric properties of R410A Gas as an alternative to SF6 for high‐voltage applications
Electric power industry is extensively using gas‐insulated systems for the transmission and distribution of electrical energy. In high‐voltage technology, the gas insulation is dom...
Air-Conditioning Using Waste Heat Energy
Air-Conditioning Using Waste Heat Energy
Abstract All oil & gas building facilities such as control room, electrical room, substation and personal accommodation etc., require a comfortable indoor condit...
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
RESULTS OF NUMERICAL SIMULATION OF GEOTHERMAL COOLING IN THE VENTILATION SYSTEM OF ANIMAL PREMISES
The microclimate of livestock premises is determined by a set of physical, chemical and biological parameters inside the premises for keeping animals and is characterized by the fo...
Optimization and Design of Carbon Dioxide Flooding
Optimization and Design of Carbon Dioxide Flooding
Abstract Increasing energy demand coupled with public concern for the environment has placed the oil industry in an awkward position as profit-making energy provider...
Adsorption Cooling With Multi-Stage Desiccant Processes
Adsorption Cooling With Multi-Stage Desiccant Processes
For traditional adsorption cooling systems using silica-gel-like desiccant wheels, the moisture is removed from the air and stored in the desiccant wheels. The subsequent reactivat...
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Analysis on The Risk of Respiratory Virus Transmission By Air Conditioning System Operation-Based on Experimental Evidence
Abstract It is important to know whether SARS-CoV-2 is spread through the air-conditioning systems. Taking the central air-conditioning system as an example, we analyze the...

Back to Top